NLP150L Series Single and triple outputs
Part | Datasheet |
---|---|
![]() |
NLP150L-96S5 (pdf) |
Related Parts | Information |
---|---|
![]() |
NLP150L-96S3 |
![]() |
NLP150L-96T658 |
PDF Datasheet Preview |
---|
NLP150L Series Single and triple outputs LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 110-150W AC/DC Universal Input Switch Mode Power Supplies 1 • 90VAC to 264VAC universal input range • Provides low voltage outputs of 3.3V • EN61000-3-2 compliant • Overvoltage and short circuit protection • Power fail detection • Current sharing on VA and VB • x inches • UL, CSA and VDE safety approvals and CE-marked to LVD • Compliance to EN55022-B conducted noise standard • Compliance to EN55022-A radiated noise standard • Meets all applicable and relevant immunity standards EN61000-4-2, -3, -4, -5 and -6 The NLP150L series of 150 Watt AC/DC open frame power supplies are available with single, triple or quad outputs. The single and triple output versions described in this datasheet are housed in a x inch package. All NLP150L series power supplies are harmonic current corrected to meet the EN61000-3-2 standard, and support current sharing. The power supplies are designed for use in 1U shelves or boxes, and are primarily intended for networking applications that have a heavy logic content, such as access concentrators, midrange routers, LAN switches and shared media hubs. All specifications are typical at nominal input, full load at 25°C unless otherwise stated Patent No. 5600546 and 5652700 2 YEAR WARRANTY SPECIFICATIONS OUTPUT SPECIFICATIONS Total regulation Line and load Main output Auxiliary outputs Turn-on delay 120VAC Input 2.0s, max. Transient response Main output 75% to 100% step at 0.1A/µs or 250mV max. dev., 1ms max. recovery to 1% Temperature coefficient ±0.02%/°C Overvoltage protection Main outputs 125%, ±10% Short circuit protection Cyclic operation Continuous Minimum output current Singles and multiple See table INPUT SPECIFICATIONS Input voltage range See Note 12 Universal input 90 to 264VAC Input frequency range 47Hz to 63Hz Input surge current 264VAC cold start 40A max. Safety ground leakage current 264VAC, 60Hz 0.99mA Input current 120VAC 150W 230VAC 150W |
More datasheets: HR01910J/8 | AS1375 | AS1375-BTDT-27 | AS1375-BTDT-25 | AS1375-BTDT-30 | AS1375-BTDT-33 | AS1375-BTDT-12 | AS1375-BTDT-18 | S553-6500-D1-F | NLP150L-96S3 |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived NLP150L-96S5 Datasheet file may be downloaded here without warranties.