LPQ112

LPQ112 Datasheet


LPQ110 Series

Part Datasheet
LPQ112 LPQ112 LPQ112 (pdf)
Related Parts Information
LPQ114-B LPQ114-B LPQ114-B
LPQ112-B LPQ112-B LPQ112-B
LPQ113 LPQ113 LPQ113
LPQ114 LPQ114 LPQ114
LPQ113-B LPQ113-B LPQ113-B
PDF Datasheet Preview
Embedded Power for Business-Critical Continuity

LPQ110 Series
110 Watts

Total Power 80 - 110 Watts Input Voltage 85-264 VAC 120-300 VDC # of Outputs Quad
1 of 3

Special Features
• Universal input
• High efficiency
• Remote sense on main output
• Built-in EMI filter
• Low output ripple
• Adjustable 5 V output
• Overvoltage protection
• Overload protection
• floating 4th output

On LPQ112 and LPQ113
• Power fail
• Optional L bracket -B suffix
• Cover kit available LPX110-C

Safety

VDE 0805/EN60950 IEC950 11774-3336-1245 LC #84997

UL UL1950 E132002 CSA Level 3

LR53982C NEMKO EN 60950/EMKO-TUE

P94102464 74-sec 203 BABT EN60950/BS7002

PS/605823 CB Certificate and report
1423, 1424, 1425 CE Mark LVD

Electrical Specifications

Input

Input
85 - 264 Vac 120 - 300 Vdc

Frequency
47 - 440 Hz

Inrush current
18 A peak 115 Vac < 36 A peak 230 Vac, cold start 25 °C

Efficiency
70% typical at full load

EMI filter

Meets FCC Class B conducted CISPR 22 Class B conducted EN55022 Class B conducted VDE 0878 PT3 Class B conducted

Safety ground leakage current Output Maximum power
mA 50/60 Hz, 264 Vac input 80 W convection 110 W with 30 CFM forced air

Adjustment range
± 5% min. on main 5 - 25 V on 4th output on LPQ112 and LPQ113

Cross regulation
± 2% on output 1 ±3% on outputs 2, 3 & 4

Hold-up time
20 ms 80 W load, 115 VAC nominal line

Overload protection circuit protection on all outputs. Case overload protected 110-145% above peak rating

Overvoltage protection - VDC on main output. Latching type, recycle AC to reset

Embedded Power for Business-Critical Continuity

Logic Control Power failure Remote sense

TTL logic signal goes high 50 - 150 msec after 5 V output. It goes low at least 4 msec before loss of regulation
2 of 3
Ordering Information

Model Number

Output Voltage

Minimum Load

Maximum Load with Convection

Cooling

Maximum Load with 30CFM Forced Air

Peak Load 1

Regulation 2

Ripple P/P PARD 3

SK1-1 SK1-3 SK1-5 SK2-1 SK2-2 SK2-3 SK2-4 SK2-5 SK2-6 SK2-7 SK2-8 SK2-9 SK2-10 SK2-11 SK2-12 SK201-1 SK201-2

GND Neutral Line +5 V +5 V +5 V Common +12 V +12 V -12 V +5-25 V -5-25 V +sense -sense

GND Neutral Line +5 V +5 V +5 V Common +15 V +15 V -15 V +5-25 V -5-25 V +sense -sense

GND Neutral Line +5 V +5 V +5 V Common +12 V +12 V -12 V +24 V Common +sense -sense

LPQ112 5 V
± 2%
50 mV

SK202-1 SK202-2

POK GND

POK GND

POK GND
± 3%
120 mV
-12 V
± 5 - 25 V 0 A
± 5%
120 mV
± 3% 240mV, max Connectors

LPQ113 5 V
± 2%
50 mV AC Input Molex 09-50-8051 USA
± 3%
150 mV
09-91-0500 UK PINS 08-58-0111
-15 V
± 5%
150 mV DC Outputs Molex 09-50-8121 USA
± 5 - 25 V 0 A

LPQ114 5 V

A 9A A
± 3%
More datasheets: 8R09-N001 | 8R25-N001 | 8R15-N001 | AO4613 | AO4613_001 | SBC1506A | SBC1407B | 12-23C/S2GHBHC-A01/2C | HSMW-C280 | 2514


Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived LPQ112 Datasheet file may be downloaded here without warranties.

Datasheet ID: LPQ112 518452