BXA3 Series Single and dual output
Part | Datasheet |
---|---|
![]() |
BXA3-24S05-F (pdf) |
Related Parts | Information |
---|---|
![]() |
BXA3-48S05 |
![]() |
BXA3-12S15-F |
![]() |
BXA3-48S12 |
![]() |
BXA3-24S05 |
![]() |
BXA3-12S3V3-F |
![]() |
BXA3-48S12-F |
![]() |
BXA3-48S05-F |
![]() |
BXA3-48S15 |
![]() |
BXA3-12S3V3 |
![]() |
BXA3-24S3V3-F |
PDF Datasheet Preview |
---|
BXA3 Series Single and dual output DC/DC CONVERTERS 3W Wide Input DC/DC Converters • 3 Watts in DIL Package • 9 models including 3.3VDC output • Wide input ranges 9-18V, 18-36V, 36-75V • EN55022 conducted emissions level A optional • Continuous short circuit protection • Operating temperature range -25°C to +105°C • Input voltage range to ETS300-132-2 • UL, VDE and CSA safety approvals The BXA3 Series of DC/DC converters is designed to offer the optimum cost/benefit power solution for a wide variety of applications including public and private telecommunications, industrial systems and process and test equipment. The series consists of 9 models with input voltages of 9-18VDC, 1836VDC and 36-75VDC, and offers standard output voltages of 3.3V, 5V, 12V and 15V in single and dual output configurations. Continuous short circuit protection, overvoltage protection, 60mV output ripple and EN55022 level A conducted noise compliance minimize design-in time, cost and eliminate the need for external components. All specifications are typical at nominal input, full load at 25°C unless otherwise stated 2 YEAR WARRANTY SPECIFICATIONS OUTPUT SPECIFICATIONS Voltage accuracy Line regulation LL to HL, all outputs Load regulation Full load to no load Ripple and noise 5Hz to 20MHz +5V output All others 60mV pk-pk, max., 15mV rms 100mV pk-pk, max., 15mV rms Temperature coefficient ±0.02%/°C, max. Over voltage protection Clamp diode 135% Vout Short circuit protection Continuous automatic recovery INPUT SPECIFICATIONS Input voltage range 12VDC 24VDC 48VDC 9 to 18VDC 18 to 36VDC 36 to 75VDC Input filter Suffix ‘-F’ See Note 5 Pi type See Note 7 protection Max. input rise and fall time Output remains within specification 5V/ms International Safety Standard Approvals VDE0805/EN60950/IEC950 Licence No. 5856 UL1950 File No. E136005 CSA C22.2 No. 950 File No. LR41062C EMC CHARACTERISTICS Conducted emissions EN55022, FCC part 15 Suffix ‘-F’ versions See Notes 5 and 6 Level A GENERAL SPECIFICATIONS |
More datasheets: ACT8930QJ134-T | ACT8930QJ133-T | FFAF10U120DNTU | AT-41533-TR1 | AT-41511-TR1 | 81549551 | 81548051 | 81549051 | EG1380A | 10303 |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived BXA3-24S05-F Datasheet file may be downloaded here without warranties.