AGQ300-48S1V2 DC/DC Converter TRN
Part | Datasheet |
---|---|
![]() |
AGQ300-48S1V2-4L (pdf) |
Related Parts | Information |
---|---|
![]() |
AGQ300-48S1V2B-4L |
![]() |
AGQ300-48S1V2P-4L |
![]() |
AGQ300-48S1V2PB-4L |
PDF Datasheet Preview |
---|
AGQ300-48S1V2 DC/DC Converter TRN AGQ300-48S1V2 DC/DC Converter Technical Reference Notes Industry standard quarter brick 36V~75V input, 1.2V single output Industry standard quarter brick open-frame x open-frame x with baseplate Options • Choice of positive logic or negative logic for CNT function • Choice of short pins or long pins • Industry standard quarter brick • Basic isolation • Ultra high efficiency • Improved thermal performance • High power density • Low output noise • Industry standard pinout • 2:1 wide input voltage of 36V~75V • CNT function • Remote sense • Trim function • Over-temperature protection • Output over-current protection hiccup • Output over-voltage protection hiccup • RoHS compliant AGQ300-48S1V2 is a new open-frame DC/DC converter for optimum efficiency and power density. AGQ300-48S1V2 is an industry standard quarter brick, which makes it an ideal choice for small space, high current and low voltage applications. The package size is 57.9mm x 36.8mm x 10.1mm x for open-frame and 57.9mm x 36.8mm x 12.7mm x with baseplate, and standard pinout configuration provides CNT and trim functions. AGQ300-48S1V2 can provide single output that is isolated from inputs. The module can achieve ultra high efficiency, for most applications a heatsink is not required. Document No. 31020734 October 29, 2009 Module Numbering AGQ300-48S1V2 DC/DC Converter TRN AGQ300-48S1V2 DC/DC Converter TRN Electrical Specifications Unless otherwise indicated, specifications apply over all operating input voltage and temperature conditions. Standard test condition on a single unit is as follows: Tc board 25°C +Vin -Vin CNT: 48V±2% Return pin for +Vin Connect to -Vin for negative logic Open for positive logic +Vout -Vout +Sense -Sense Trim Vadj : Connect to load Connect to load return Connect to +Vout Connect to -Vout Open Input Specifications Parameter Operating input voltage Maximum input current VI=0 to VI,max, Io=Io,max Input reflected-ripple current rated input and output Supply voltage rejection 120Hz II,max Unit Vdc A mAp-p CAUTION This power module is not internally fused. An input line fuse must always be used. AGQ300-48S1V2 DC/DC Converter TRN Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only. Functional operation of the device is not implied at these or any other conditions in excess of those given in the operational sections of the IPS. Exposure to absolute maximum ratings for extended periods can adversely affect device reliability. Parameter Symbol Min Unit Input voltage Continuous Transient 100ms VI, trans Ordering Information Model number Input voltage AGQ300-48S1V2-4L 36 ~ 75 AGQ300-48S1V2P-4L 36 ~ 75 AGQ300-48S1V2B-4L 36 ~ 75 AGQ300-48S1V2PB-4L 36 ~ 75 AGQ300-48S1V2-4Y 36 ~ 75 Output voltage Output current Ripple and noise mV pp Negative Positive Negative Positive Negative Efficiency % Typ. AGQ300-48S1V2 DC/DC Converter TRN Cr6+ PBDE SJ/T-11363-2006 SJ/T-11363-2006 Cr6+ PBDE SJ/T-11363-2006 SJ/T-11363-2006 |
More datasheets: Z8F04A08100KITG | 76000774 | AS1357 | AS1357V-T | AS1357-T-F | AS1357V | 18059USA | 204-10UYC/S400-A8 | CY7C1069AV33-1XW14 | FJY3001R |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived AGQ300-48S1V2-4L Datasheet file may be downloaded here without warranties.