NLP70 Series Triple output
Part | Datasheet |
---|---|
![]() |
NLP70-9693 (pdf) |
PDF Datasheet Preview |
---|
NLP70 Series Triple output LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 70 W AC/DC Universal Input Switch Mode Power Supplies • Provides up to A on either V or 5 V • x inch card and inch package 1U applications • V, 5 V and 12 V triple • EN61000-3-2 compliant • Overvoltage and short circuit protection • EN55022, EN55011 conducted emissions level B • EN61000-4-2, -3, -4, -5, -6 immunity compliant • Mounting holes as per NLP65 series, easy upgrade • Available RoHS compliant The NLP70-9693J is a 70 W with forced air universal input ac-dc power supply on a x 3 inch card with a maximum component height of inches for use in 1U applications. The model has input harmonic current correction making the series ideal for product designs that need to comply with EN61000-3-2 legislation. The NLP70 provides W of output power with free air convection cooling which can be boosted to 70 W with 20 CFM of air. The NLP70, with full international safety approval and the CE mark, meets conducted emissions EN55022 level B and has immunity compliance to EN610004-2, -3, -4, -5, The NLP70 series is designed for use in low power data networking, computer and telecom applications using V or 5 V logic. The NLP70 can provide the same current on either the V or 5 V channel making it ideal for applications using a mixture of 3.3V and 5V logic or for applications in transition from 5 V to V logic. All specifications are typical at nominal input, full load at 25 °C unless otherwise stated 2 YEAR WARRANTY SPECIFICATIONS OUTPUT SPECIFICATIONS Total regulation line and load V and 5 V 12 V Rise time At turn-on s, max. Transient response Main output 25% step at A/µs or 250 mV max. dev., 1 ms max. recovery to Temperature coefficient ±0.02%/°C Overvoltage protection Main outputs 125%, ±10% Short circuit protection Cyclic operation Continuous Minimum output current See Note 6 INPUT SPECIFICATIONS Input voltage range Universal input 90-264 Vac Input frequency range 47-63 Hz Input surge current cold start 120 Vac 230 Vac 17 A max. 32 A max. Safety ground leakage current 120 Vac, 60 Hz 230 Vac, 50 Hz Input current 120 Vac, with PFC 230 Vac, with PFC A rms A rms Input fuse UL/IEC127 |
More datasheets: TSL253R-LF | 88970085 | 88970084 | FQPF4N90 | TRTEP13S-U587B015 | AD5300BRT-R2 | M4243 BK005 | M4243 BK001 | M4243 BK002 | 10821F |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived NLP70-9693 Datasheet file may be downloaded here without warranties.