EXQ60D Series
Part | Datasheet |
---|---|
![]() |
EXQ60-48D05-3V3 (pdf) |
Related Parts | Information |
---|---|
![]() |
EXQ60-48D05-3V3-R |
![]() |
EXQ60-48D3V3-2V5-R |
![]() |
EXQ60-48D3V3-2V5 |
PDF Datasheet Preview |
---|
EXQ60D Series Dual positive output DC/DC CONVERTERS 60 W High Efficiency DC/DC Converters • Two positive outputs • Output voltage tracking • High efficiency • Approved to EN60950 TÜV Rheinland , UL/cUL1950 • Operating baseplate temperature of -40 °C to +100 °C • Up to 100% load imbalance • Trim function • No minimum load • Complies with ETS 300 019-1-3/2-3 • Fully compliant with ETS 300 386-1 • Available RoHS compliant The EXQ60 is a new high efficiency, open frame, isolated 60 Watt converter series in an industry standard quarter-brick footprint. The EXQ60 delivers very high output current at low voltages, and excellent useable power density for today's high end applications. The first two models in the series feature an input voltage range of 33 V to 75 V and are available in output voltages of V and V. The output voltage on each model is adjustable from 90% to 110% of the nominal value. Typical efficiencies for the models are 91% for the V and 90% for the V version. The EXQ60 series also has a remote on/off capability. Overcurrent and overvoltage protection features are included as standard. With full international safety approval including EN60950, TÜV Rheinland and UL/cUL1950, the EXQ60 reduces compliance costs and time to market. All specifications are typical at nominal input, full load at 25 °C unless otherwise stated 2 YEAR WARRANTY SPECIFICATIONS OUTPUT SPECIFICATIONS Voltage adjustability Both outputs ±10% Setpoint accuracy Both outputs See Note 1 ±1% max. Output voltage over all line and load conditions V < Vo1 < V < Vo2 < V V < Vo1 < V < Vo2 < V Minimum load Both outputs Ripple and noise 20 MHz bandwidth 60 mV pk-pk max., 20 mV rms max. Transient response 50% to 75% and back 120/80 mV peak dev. settling time to no external cap. 100 µs Short circuit protection Both outputs Tracking Outputs track start-up and shutdown INPUT SPECIFICATIONS Input voltage range 48 Vin nominal 33-75 Vdc Input current No load Remote OFF 60 mA max. 20 mA max. UVLO turn ON voltage UVLO turn OFF voltage 33 V typ 30 V typ Start-up time 60 Watts for D05-3V3 models 40 Watts for D3V3-2V5 models. 4 The EXQ60D features ‘Active High’ Remote ON/OFF as standard. An ‘Active Low’ Remote ON/OFF version is also available. To order the ‘Active Low’ version of the EXQ60-48D05-3V3J please add the suffix ‘-R’ towards the end of the part number, i.e. EXQ60-48D05-3V3-RJ. As our part numbers cannot exceed 18 characters when ordering the ‘Active Low’ version of the EXQ60-48D3V3-2V5J please add the suffix ‘R’ towards the end of the part number, i.e. EXQ60-48D3V3-2V5RJ. 5 When ordering pin lengths designate with suffix ‘-K‘. If the product is already a ‘-R’ suffix product then the suffix will be ‘-RK’. 6 The ‘J’ suffix indicates that these parts are Pb-free RoHS 6/6 compliant. TSE RoHS 5/6 non Pb-free compliant versions may be available on special request, please contact your local sales representative for details. CAUTION Hazardous internal voltages and high temperatures. Ensure that unit is not user accessible. PIN CONNECTIONS PIN NUMBER FUNCTION +Vin Remote On/Off -Vin Output Return Trim Bottom View 7 PLS M3 x Threaded Through 4 PLS *Standard available pin length. option also available. See Note 5 for ordering details Top View ALL DIMENSIONS IN INCHES [mm] International Safety Standard Approvals UL/cUL UL1950 File No. E135734 TÜV Rheinland Certificate No. 40013415 File No. 10401-3336-0208 CB Scheme No. DE1-32228 4 PLS 7 6 5 4 7 PLS Recommended Hole Pattern Datasheet Artesyn 2006 The information and specifications contained in this datasheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product s or information contained herein. Please consult our website for the following items Application Note Longform Data Sheet |
More datasheets: 74ACTQ08PC | 74ACTQ08SJ | 74ACTQ08SC | 7343-2UYC/H2/S530-A3 | CS42428-CQZR | CS42428-CQZ | CS42428-DQZR | CS42428-DQZ | EXQ60-48D05-3V3-R | EXQ60-48D3V3-2V5-R |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived EXQ60-48D05-3V3 Datasheet file may be downloaded here without warranties.