6966 HEAT GUN

READ SAFETY INSTRUCTIONS ON PAGE 3 BEFORE OPERATING HEAT GUN.

OPERATION Connect power cord to main AC outlet. Do not use DC . Place appropriate baffle over nozzle of gun before turning power switch on. The trigger power switch has three positions. The Hot Air II position will produce air tem perature at nozzle of approximately 800°F in 10 seconds. SWITCH TO COLD AIR 30-45 SECONDS BEFORE TURNING OFF. This will increase the life of the heating element. Keep nozzle at least 1/4" from the surface to be heated. Restricting the air flow from the nozzle may cause damage to your heating element. CAUTION Heat Gun should never be placed in a position where the stream of hot air is directed onto table surfaces or flammable materials. The Heat Guns may be operated in several positions.

SelfStanding

Suspended

With 6965A Holder

To remove or change baffles when hot, simply trigger power switch to Cool Air position I hold handle of gun in one hand and remove the hot baffle with a pair of long nose pliers.

HEAT GUN BAFFLE ACCESSORIES
6956 Shrink Tubing

Reflector 1/2" Reflector, 3/4" Diameter Designed for general heat shrinking applications.
6958 Reducing Baffle For critical heat direction. Reduces air flow at nozzle to
6957 Shrink Tubing

Reflector 1/4" Reflector,
3/4" Diameter For larger shrinking applications.
6964 Precision Reflector Designed for shrinking miniature tubing and in-
sulators.

Important Safety Instructions

Read These Instructions Hidden areas such as behind walls, ceilings, floors, soffit boards and other panels may contain flammable materials that could be ignited by the heat gun when working in these locations. The ignition of these materials may not be readily apparent and could result in property damage and injury to persons. When working in these locations, keep the heat gun moving in a back-and-forth motion. Lingering or pausing in one spot could ignite the panel or the material behind it. WARNING Extreme care should be taken when stripping paint. The peelings, residue and vapors of paint may contain
lead, which is poisonous. Any pre-1977 paint may contain lead and paint applied to homes prior to 1950 is likely to contain lead. Once deposited on surfaces, hand to mouth contact can result in the ingestion of lead. Exposure to even low levels of lead can cause irreversible brain and nervous system damage young and unborn children are particularly vulnerable. Before beginning any paint removal process you should determine whether the paint you are removing contains lead. This can be done by your local health department or by a professional who uses a paint analyzer to check the lead content of the paint to be removed. Lead based paint should only be removed by a professional and should not be removed using a heat gun.

Persons removing paint should follow these guidelines:

Move the work piece outdoors. If this is not possible, keep the work area well ventilated. Open the window and put an exhaust fan in one of them. Be sure the fan is moving the air from inside to outside.

Remove or cover any carpets, rugs, furniture, clothing, cooking utensils and air ducts. Place drop cloths in the work area to catch any paint chips or peelings. Wear protective clothing such as extra
work shirts, overalls and hats. Work in one room at a time. Furnishings should removed or placed in the center of the room and covered. Work
areas should be sealed off from the rest of the dwelling by sealing doorways with drop cloths. Children, pregnant or potentially pregnant women and nursing mothers should not be present in the work area
until the work is done and all clean up is complete. Wear a dust respirator mask or a dual filter dust and fume respirator mask which has been approved by the

Occupational Safety and Health Administration OSHA , the National Institute of Safety and Health NIOSH , or the United States Bureau of Mines. These masks and replaceable filters are readily available at major hardware stores. Be sure the mask fits. Beards and facial hair may keep masks from sealing properly. Change filters often.

Disposable paper masks are not adequate.

Use caution when operating the heat gun. Keep the heat gun moving, as excessive heat will generate fumes which can be inhaled by the operator.

Keep food and drink out of the work area. Wash hands, arms and face and rinse mouth before eating or drinking. Do not smoke or chew gum or tobacco in the work area.

Clean up all removed paint and dust by wet mopping the floors. Use a wet cloth to clean all walls, sills and any other surface where paint or dust is clinging. Do not sweep, dry dust or vacuum. Use a high phosphate detergent or trisodium phosphate TSP to wash and mop areas.

At the end of each work session put the paint chips and debris in a double plastic bag, close it with tape or twist ties, and dispose of properly.

Remove protective clothing and work shoes in the work area to avoid carrying dust into the rest of the dwelling. Wash work clothes separately. Wipe shoes off with a wet rage that is then washed with the work clothes. Wash hair and body thoroughly with soap and water.

II. Disassembly
a. Insert diagonal pliers under head of ferrule drive screw 1 and remove. b. Slide ferrule 25 forward to remove. c. Open wire hanger 7 and remove. d. Remove screws 18 and 23 and screw and nut e. Lift left housing 12 to expose inner assembly.

III. Assembly
a. Position cord protector 19 as shown. b. Check wiring for shorts and grounds. c. Position left housing 12 , aligning screw holes. d. Replace screws 18 and 23 and screw and not e. Replace switch 21 by snapping into place. Make sure it is well-seated. f. Replace ferrule 25 , aligning screw hole and press in drive screw g. Close wire hanger 7 into holes of housing assembly

IV. Cone and Insulator Assembly
a. Disassemble per Section II. b. Cut off wire nut c. Remove scroll and motor assembly Remove screw 13 and lift scroll and motor assembly 10 off
right housing
d. Remove cone and mica insulator assembly Squeeze wide end of cone 2 to top and bottom to release from tabs 3 on scroll assembly, remove tape strips to release cone.
e. Remove mica insulator 24 from heating element with diode assembly Replace with new mica insulator packaged in replacement cone and insulator assembly.