US681-C00005-500PG

US681-C00005-500PG Datasheet


US6 Output US6 X

Part Datasheet
US681-C00005-500PG US681-C00005-500PG US681-C00005-500PG (pdf)
Related Parts Information
US631-C00005-015PG US631-C00005-015PG US631-C00005-015PG
US631-C00005-030PG US631-C00005-030PG US631-C00005-030PG
US631-C00005-015PA US631-C00005-015PA US631-C00005-015PA
US681-C00005-100PA US681-C00005-100PA US681-C00005-100PA
US681-C00005-015PA US681-C00005-015PA US681-C00005-015PA
US681-C00005-030PG US681-C00005-030PG US681-C00005-030PG
US681-C00005-100PG US681-C00005-100PG US681-C00005-100PG
US681-C00005-030PA US681-C00005-030PA US681-C00005-030PA
US681-C00005-015PG US681-C00005-015PG US681-C00005-015PG
US631-C00005-100PA US631-C00005-100PA US631-C00005-100PA
US631-C00005-030PA US631-C00005-030PA US631-C00005-030PA
US631-C00005-100PG US631-C00005-100PG US631-C00005-100PG
US631-C00005-500PG US631-C00005-500PG US631-C00005-500PG
PDF Datasheet Preview
UltraStable 600

High Stability Stainless Steel Pressure Transducer

The UltraStable 600 from Schaevitz Sensors, a division of Measurement Specialties, incorporates an ultra-rugged IP 67 rated housing. All wetted parts are constructed of 316L stainless steel, providing media isolation and no internal “O” rings.

The UltraStable 600 also offers a wide selection of standard pressure ranges and electrical outputs. The unit's high stability rating is provided by IC Sensors' solid state UltraStable technology, which provides stability over a wide temperature range. The modular design is adaptable to an infinite number of port variations, and standard outputs include .5V to 4.5V ratiometric, 0V to 5V, 1V to 5V, 0V to 10V, regulated and 4 to 20mA current loop.

The UltraStable's small size vs. high performance enables the miniaturization of high accuracy pressure and vacuum systems. The unit's new low-pressure ranges add sensitivity that has previously been unavailable in transducers of this size. The competitive price, coupled with its high accuracy, may make the UltraStable 600 the best choice for your application.

TEB Total Error Band with TEB available as an option

Accuracy - typically
-50 to 125º C Operating Temperature
100% stainless steel isolation. Small size

Wide variety of pressure ranges and electrical outputs

Broad assortment of standard connectors and ports

UltraStable sensing technology

CE versions available

Custom verisons available

Ranges starting from 15 psi FS

High field Interchangeability

Field replacement can easily be performed without sacrificing accuracy due to the very small total error band of max.

A Division of

Refrigeration and HVAC controls Process control Marine systems Tank level Industrial machinery Calibration equipment
04/02

UltraStable 600

Units

Supply voltage V Supply Current mA Min load impedance Max load impedance

Static Performance Specifications

Amplified Ratiometric - V out

Min. Typ. Max.
100 K ohm

Amplified 0-5 V, 1-5 V, 0-10 V out

Min. Typ. Max.
100 K ohm

Amplified 4 to 20 mA , two wire

Min. Typ. Max.

RL=50* Vsupply-10

Accuracy %FS Offset %FS Span %FS Long Term stability %FS/year

Response time ms

Isolation

Resistance M ohm
1 Supply voltage must be 12 V for units with 10 V out.
4 Over temp range -20 to +85º C
2 Room temperature calibration.
5 50 V DC
Ordering Information

US6 Output US6 X

Output
to 4.5V ratio 1 4= 1 to 5V 6= 0 to 5V 7= 0 to 10V 8=4-20 mA

X=Special output

Electrical Connection

Connection
1=Cable 2 feet 4 = Integral Packard 5 = PTIH-10-6P Bendix style 6 = GSSR 300 mm Square Hirshman 8 = PTIH-08-4P Bendix Style x = Special Connection

Specials

Port type X

Specials

Port

For Non-Standard 2= 1/4-19 BSP
the standard num- 4= 7/16-20 UNF
ber of
5=1/4-18 NPT
changes to a higher 6= 1/8-27 NPT
value .i.e 1XXXX

Special numbers starting with a “C” are CE rated

X= special port

Pressure range

XXXX

Pressure unit X

Pressure Range

Pressure Units

PSI Ranges

Bar Ranges

A = absolute

G = gauge
001B = 0 to 1 Bar
015P = 0 to 15 psi 002B = 0 to 2 Bar
030P = 0 to 30 psi 005B = 0 to 5 Bar
050P = 0 to 50psi 007B = 0 to 7 Bar
100P =0 to 100psi 010B = 0 to 10 Bar
300P = 0 to 300psi 020B = 0 to 20 Bar
500P - 0 to 500psi 035B = 0 to 35 Bar
01KP = 0 to 1Kpsi 03KP = 0 to 3Kpsi 05KP = 0 to 5Kpsi
070B = 0 to 70 Bar 200B = 0 to 200 Bar 350B = 0 to 350 Bar

Example is an UltraStable 600 with 0 to 5V out, Packard Connector, nothing special, 1/4 NPT pressure port and 100 psi gage. US681-C00002- 005PG is an UltraStable 600 with 4-20 mA, 2-wire, output, 2 feet of cable, CE certified, 1/4 BSP male pressure port and 5 psi gage.
1 For ratiometric output, span changes with input voltage see supply voltage specifications

Sensors
More datasheets: M2004-01-625.0000T | M2004-01-666.5140T | M2004-01-666.5140 | CA3102R28-22PB | CA3102R20-27SF0 | US631-C00005-015PG | US631-C00005-030PG | US631-C00005-015PA | US681-C00005-100PA | US681-C00005-015PA


Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived US681-C00005-500PG Datasheet file may be downloaded here without warranties.

Datasheet ID: US681-C00005-500PG 647617