EN 50081-2 EN 50082-2 10V/M, 26-1000MHz EN 61326 Effective July 1, 2001
Part | Datasheet |
---|---|
![]() |
2000872 (pdf) |
Related Parts | Information |
---|---|
![]() |
2000989 |
![]() |
2000973 |
![]() |
2000901 |
![]() |
2000908 |
![]() |
2000895 |
![]() |
2000896 |
![]() |
2000897 |
![]() |
2000968 |
![]() |
2000967 |
![]() |
2000988 |
![]() |
2000891 |
![]() |
2000902 |
![]() |
2000903 |
![]() |
2000969 |
![]() |
2000979 |
![]() |
2000907 |
![]() |
2000993 |
![]() |
2000978 |
![]() |
2000883 |
![]() |
2000871 |
![]() |
2000873 |
![]() |
2000964 |
![]() |
2000877 |
![]() |
2000977 |
![]() |
2000879 |
![]() |
2000909 |
![]() |
2000884 |
![]() |
2000885 |
![]() |
2000966 |
![]() |
2000986 |
![]() |
2000889 |
![]() |
2000890 |
![]() |
2000878 |
![]() |
2000972 |
![]() |
2000983 |
![]() |
2000933 |
![]() |
2000932 |
![]() |
2000931 |
![]() |
2001118 |
![]() |
2001117 |
![]() |
2001116 |
![]() |
2000927 |
![]() |
2000926 |
![]() |
2000925 |
![]() |
2000982 |
![]() |
2000970 |
![]() |
2000921 |
![]() |
2000920 |
![]() |
2000914 |
![]() |
2000980 |
![]() |
2000990 |
![]() |
2000992 |
![]() |
2000913 |
![]() |
2000919 |
![]() |
2000915 |
![]() |
2000971 |
![]() |
2000981 |
![]() |
2000991 |
![]() |
2000987 |
![]() |
2000985 |
![]() |
2000984 |
![]() |
2000976 |
![]() |
2000974 |
![]() |
2000975 |
![]() |
2000965 |
PDF Datasheet Preview |
---|
SPECIALTIES s 1% Total Error Band s No Leaks s No Welds s No “O” Rings s No Silicone Oil CODNMIGEPDIWTEEANSLSILGAYNTED Microfused Technology MSP-600 New High Accuracy, Digitally Compensated EMI/RFI Protected Stainless Steel Isolated Pressure Transducer s High Accuracy s Low Cost OEM s 100% Leak Proof High Accuracy Digitally Compensated One-piece Stainless Steel Construction Ranges up to 10,000 PSI or 700 BAR Amplified Outputs Wide Operating Temperature Range Low Pressure Configuration Pumps and Compressors Hydraulic/Pneumatic Systems Off Road/Mobile Equipment Energy and Water Management Pressure Instrumentation Refrigeration Equipment Agriculture Equipment Train Braking Systems LISTED The MSP series pressure transducers set a new price-performance standard for low cost, high volume, commercial and industrial applications. This series is suitable for measurement of liquid or gas pressure, even for difficult media such as contaminated water, steam, and mildly corrosive fluids or gases. The transducer pressure cavity is machined from a solid piece of 17-4 PH stainless steel. The standard version includes a 1/4" NPT pipe thread allowing a leak-proof, all metal sealed system. There are no “o”-rings, welds or organics exposed to the pressure media. The durability is excellent. Measurement Specialties proprietary Microfused technology, derived from demanding aerospace applications, employs micromachined silicon piezoresistive strain gages, fused with high temperature glass to a stainless steel diaphragm. This approach achieves media compatibility simply and elegantly providing an exceptionally stable sensor without the p-n junctions of conventional micromachined sensors. This product is geared to the OEM customer using medium to high volumes. The standard version is suitable for many applications, but the dedicated design team at our Transducer Engineering Center stands ready to provide a semi-custom design where the volume and application warrants. SPECIFICATIONS Performance at Pressure range Accuracy, % of FS Span combined linearity, hysterisis and repeatability Media compatibility Pressure cycles Pressure overload Burst pressure Long term stability 1 year Electrical: Supply voltage Supply current Output Load impedance Bandwidth Standard connector options 0-25, 50, 75, 100, 250, 500, 1000, 2500, 5000, 7500, 10000 PSI 0-3, 6, 7, 17, 35, 70, 175, 350, 525, 700 BAR ± BSL, max per ISA S37.2 17-4 PH stainless steel optional 316L stainless 10 million, minimum 2 times rated pressure 4 times full scale or 20,000 PSI, whichever is less ± FS Span Typical Ratiometric Non-Ratiometric to 5.25VDC 10 - 30VDC <10mA <25mA to 4.5V, at 5V 3 1 - 5V, three wires 4 4 - 20mA, two wires 5 > 100k Ohms for quoted performance for 4 - 20mA 0.05 Vsupply-10 k Ohms maximum DC to 1KHz Typical Packard connector - Metri-pack 150, 3 pins Cable - 24" length Additional connectors available upon request ORDERING MSP600 Pressure Range P = PSI B = BAR Outputs 3 = - 4.5VDC 4 = 1- 5VDC 5 = 4-20mA two wire 1= 2 ft. cable N = 1/4" NPT 4= Packard connector * for other options consult factory Electrical Connections: Outputs: Red +Supply Black Ground White Output 5 Red +Supply Black Output UNITED STATES Measurement Specialties, Inc. PO Box 799 Valley Forge, PA 19482 Tel 610 650-1500 Fax 610 650-1509 Email Web site: P/N 2001317 10/00 Dimensions In Inches And Are Reference Only MEASUREMENT SPECIALTIES |
More datasheets: 2000891 | 2000902 | 2000903 | 2000969 | 2000979 | 2000907 | 2000993 | 2000978 | 2000883 | 2000871 |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived 2000872 Datasheet file may be downloaded here without warranties.