HM1500LF Relative Humidity Module
• Small size product
• Product free from Lead, Cr 6+ , Cd and Hg
• Humidity calibrated within +/-2%
• Typical 1 to Volt DC output for 0 to 100% RH at
5Vdc supply
• Ratiometric to voltage supply from 4.75Vdc to 5Vdc
• Patented solid polymer structure

Based on the rugged HS1101LF capacitive humidity sensor, HM1500LF is a dedicated humidity transducer designed for OEM applications where a reliable and accurate measurement is needed. Direct interface with a micro-controller is made possible with the module’s linear voltage output.
• Full interchangeability
• High reliability and long term stability
• Not affected by water immersion
• Very low temperature dependence
• Suitable for 3 to 10 Vdc supply voltage
• Industrial
• Process control


Humidity Sensor Specific features Instantaneous de-saturation after long periods in saturation phase Fast response time Part could be washed with distilled water
1 Soldering temperature profiles available on request / contact us at

PERFORMANCE SPECS

MAXIMUM RATINGS

Ratings Storage Temperature Storage Humidity Supply Voltage Peak Humidity Operating Range Temperature Operating Range

Symbol Tstg RHstg Vs RH Ta

Value -30 to 70 0 to 100
10 0 to 100 -40 to 60

Unit °C % RH Vdc % RH °C

HM1500LF HPC062_F

October 2012

HM1500LF Relative Humidity Module

ELECTRICAL CHARACTERISTICS

Ta=23°C, Vs=5Vdc +/-5%, R unless otherwise stated

Humidity Characteristics Humidity Measuring Range Relative Humidity Accuracy 10 to 95% RH Supply Voltage regulated at 5Vdc* Nominal Output at 5Vdc Current consumption Temperature Coefficient 10 to 50°C Average Sensitivity from 33% to 75%RH Sink Current Capability Humidity Hysteresis Time Constant at 63% of signal, static 33% to 75%RH Warm up time electronic Humidity resolution Output Impedance *Maximum power supply ramp up time to Vcc should be less than 4ms.

Symbol RH Vs Vout Ic Tcc
+/-3
150 70

Max 100 +/-5
150 +/-1 10

Unit %RH %RH Vdc

V mA %RH/°C mV/%RH µA %RH
s ms %RH

TYPICAL PERFORMANCE CURVES

HUMIDITY SENSOR
• Measurement conditions

HM1500LF is specified for accurate measurements within 10 to 95% RH.

Excursion out of this range <10% or >95% RH, including condensation does not affect the reliability of HM1500LF characteristics.

Dedicated HM15XX products are available for extreme RH conditions as HM1520 for low dewpoints . Consult MEASFRANCE for further information.
• Modeled Signal Output

RH % 10 15 20 25 30 35 40 45 50

Vout mV 1325 1465 1600 1735 1860 1990 2110 2235 2360

RH % 55 60 65 70 75 80 85 90 95

Vout mV 2480 2605 2730 2860 2990 3125 3260 3405 3555
ORDERING INFORMATION

HPP805A031 MULTIPLE PACKAGE QUANTITY OF 10 PIECES HM1500LF HUMIDITY ANALOG VOLTAGE OUTPUT

Sample kit of HM1500LF is available through MEASUREMENT SPECIALTIES web site:

Customer Service contact details Measurement Specialties, Inc - MEAS France

Impasse Jeanne Benozzi CS 83 163
31027 Toulouse Cedex 3 FRANCE

Tél +33 0 5 820 822 02 Fax +33 0 5 820 821 51 Sales:

HM1500LF HPC062_F

October 2012

HM1500LF Relative Humidity Module

Comments Power supply ramp up time specification added HPP Number updated, RoHS logo added

Standardized datasheet format and Current consumption lowering updated New MEAS template, MEAS-France contact details updated

Who C.EISMANN D. LE GALL D. LE GALL

D. LE GALL-ZIRILLI

Date September 06 September 07

April 08

October 12

HM1500LF HPC062_F

October 2012
More datasheets: DBM17W2PA101 | H-AP-ETHERNET-1-3 | SPI80N06S2L-05 | SPB80N06S2L-05 | SPP80N06S2L-05 | ML621-TZ1 | DEY-9S-A191-A197 | IRLR120ATF | MIKROE-2822 | 192-104QET-A01


Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived HPP805A031 Datasheet file may be downloaded here without warranties.

Datasheet ID: HPP805A031 647583