TMX-350
Part | Datasheet |
---|---|
![]() |
TMX-353-0512G (pdf) |
Related Parts | Information |
---|---|
![]() |
TMX-354-1212G |
PDF Datasheet Preview |
---|
TMX-350 350 WATTS MULTIPLE OUTPUT 48 VDC INPUT, HOT SWAP Featuring: • Diode isolated outputs for hot swap • “Zero wire” slope program current sharing • Self-aligning connector with solid metal, machined contacts • Identical output performance as RMX-350 Series • Dual converter design eliminates interaction between logic and auxiliary outputs • Low ripple and noise on all outputs • DC power good signal • True remote inhibit • Monotonic turn-on and turn-off STANDARD TMX SERIES MODEL TMX-353-0512 TMX-354-1205 TMX-354-1212 TMX-354-1224 TMX-354-1512 TMX-354-1524 PWR OUTPUT #1 350 +5V 50A 350 +5V 50A 350 +5V 50A 350 +5V 50A 350 +5V 50A 350 +5V 50A OUTPUT #2 +12V 8/12A pk +12V 8/12A pk +12V 8/12A pk +12V 8/12A pk +15V 4A +15V 4A OUTPUT #3 -12V 4A -12V 4A -12V 4A -12V 4A -15V 4A -15V 4A OUTPUT #4 5.2V 5A 12V 5A 24V 3A 12V 5A 24V 3A Maximum power from outputs #2, #3 and #4 to be less than 170W TMX Series power supplies are designed to meet applicable Bellcore and NEBS standards, so they are readily operated from Central Office power 48 Vdc . They are DC clones of Condor’s RMX Series power supplies. The RMX and TMX power supplies are directly interchangeable. They allow you to operate existing systems from AC or DC power without compromising performance or making any mechanical changes for mounting or cooling. TMX and RMX Series power supplies can also be operated in redundant configurations to achieve AC operation with battery backup capability. RMX 350 SEE FOEQRUAIVCAINLEPNUTT Condor D.C. Power Supplies, Inc., A subsidiary of SL Industries, Inc. 805-486-4565 • 800 235-5929 Fax 805 487-8911 TMX-350 lbs - kgs 350 WATTS 10.75”x 4.8”x TMX-350 Dimensions Inches Millimeters SPECIFICATIONS ALL MODELS OPTIONS INPUT DC Input 40-60 Vdc. Internally fused for 15 A. Efficiency 75% typical. Low Input Provides TTL “0” when input is below 40 Vdc. Consult factory for available options. DC INPUT OUTPUT Adjustability Outputs #1 and 2, and 4 factory adjusted to nominal Output #3 tracks #2 initial accuracy Line & Load Reg Outputs #1, 2, and 4 hold ±2% with local sense over dc input range and 0 to 100% load change preprogrammed slope . Output #3 requires 20% minimum load on outputs #2 and 3 to hold Ripple & Noise 1% p-p or 100 mV, whichever is greater. Remote Sense Output #1 Compensates for 250 mV total line drop. Preprogrammed slope remains under ±3% worst case. Open sense lead protection. Temperature Coefficient Outputs #1, 2, and 4 per degree C. Stability over 8 hours after 30 minutes warm-up. Transient Response Outputs #1, 2, and 4 Output voltage returns to within 1% in less than 500 µs for a 50% load change measured with rise time and fall time of 200 µs . Peak transient does not exceed Overload Protection All outputs are protected against overload and short circuit. Automatic recovery upon removal of fault. Overvoltage Protection Outputs #1 and 2 Protects load against power supply induced overvoltage. Trip point is factory set so that output voltage cannot exceed 136% of nominal. Peak Output Current Dual current ratings define continuous and peak currents. The peak current shown can be delivered for a maximum period of 30 seconds. |
More datasheets: MAL218697509E3 | MAL218697554E3 | MAL218697601E3 | MAL218697607E3 | MAL218697001E3 | MAL218697108E3 | MAL218697106E3 | MAL218697005E3 | B49410B2276Q000 | P1011U2WMWCNQ1 |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived TMX-353-0512G Datasheet file may be downloaded here without warranties.