NMX-750, Power Factor Corrected Multiple Output, Forced Current Sharing
Part | Datasheet |
---|---|
![]() |
NMX-754-1224G (pdf) |
Related Parts | Information |
---|---|
![]() |
NMX-754-1224 |
![]() |
NMX-754-1224BG |
![]() |
NMX-754-1205G |
![]() |
NMX-754-1212G |
![]() |
NMX-754-1205BG |
![]() |
NMX-754-1212BG |
PDF Datasheet Preview |
---|
NMX-750, Power Factor Corrected Multiple Output, Forced Current Sharing FEATURES: • Forced current sharing for N +1 redundancy • Remote sense on outputs #1 and 2 • Universal ac input • typical power factor • Dual converter design eliminates interaction between logic and auxiliary outputs • Low ripple and noise on all outputs • Dc power good and ac power fail signals • True remote inhibit • Monotonic turn-on and turn-off SPECIFICATIONS: INPUT Ac Input 90-264 Vac continuous range, 47 to 63 Hz. Internally fused for 15 A. Power Factor typical at full load. Meets EN61000-3-2 Class A. Inrush Cold start ac current is less than 65 A at 115 Vac and 130 A at 230 Vac. Limited by thermistor. Brownout Protection Holds regulation to 85 Vac. Holdup Time 20 ms minimum after removal of power at full load. Efficiency 75% typical. Ac Power Fail Provides TTL “0” 5 ms before output voltage goes out of regulation band upon loss of ac power. OUTPUT Adjustability Outputs #1 and 2 user adjustable ±5% minimum. Output #3 tracks #2 initial accuracy Output #4 user adjustable ±5% minimum, or +5% only if voltage is V. Line & Load Reg Outputs #1, 2, and 4 hold ±1% over ac input range and 0 to 100% load change. Output #3 requires 20% minimum load on outputs #2 and 3 to hold Ripple & Noise Less than 1% p-p or 100 mV, whichever is greater. Remote Sense Outputs #1 and 2 Compensates for 250 mV total line drop. Open sense lead protection. See Redundancy. Temperature Coefficient Outputs #1, 2, and 4 per degree C. Stability over 8 hours after 30 minutes warm-up. Transient Response Outputs #1, 2, and 4 Output voltage returns to within 1% in less than 500 µs for a 50% load change. Peak transient does not exceed Overload Protection All outputs are protected against overload and short circuit. Automatic recovery upon removal of fault. Overvoltage Protection Outputs #1 and 2 Protects load against power supply induced over voltage. Trip point is factory set so that output voltage cannot exceed 136% of nominal. Peak Output Current Dual current ratings define continuous and peak currents. The peak current shown can be delivered for a maximum period of 30 seconds. Remote Inhibit Contact closure to the negative sense line or a TTL level “0” turns off dc outputs. Dc Power Good Provides a TTL “1” when output #1 is above V nominal. OPTIONS Option “B”, Barrier Strip Provides auxiliary output connections on #6-32 terminal screws with 3/8” centers. AC INPUT 90-264 VAC Continuous Range FUNCTION 115 VAC 230 VAC CONNECTOR TB1- L Line Line 1 Barrier strip TB1- N Neutral Line 2 #6-32 screws, 3/8" centers TB1- GND Safety Ground Safety Ground DC OUTPUT FUNCTION LOCATION NOTES CONNECTOR Output #1 Terminal marked +V Terminal marked -V Main output Rtn common Bus bars #1/4-20 screws Output #2 Output #3 Output #4 J6-3, 11, 4, 12 J6-5, 13, 6, 14, 7, 15 J6-8, 16 J6-5, 13, 6, 14, 7, 15 J6-1, 9 Rtn common Rtn common + Floating Output AMP#770974-1 mates with connector 770583-1 with sockets #171639-1 AWG #20 to #16 J6-2, 10 - Floating Output STATUS AND CONTROL FUNCTION |
More datasheets: 5563604324F | 5563605324F | 5563705324F | 26700-209 | NMX-754-1224 | NMX-754-1224BG | NMX-754-1205G | NMX-754-1212G | NMX-754-1205BG | NMX-754-1212BG |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived NMX-754-1224G Datasheet file may be downloaded here without warranties.