GPFM115-5G

GPFM115-5G Datasheet


GPFM115 Medical

Part Datasheet
GPFM115-5G GPFM115-5G GPFM115-5G (pdf)
Related Parts Information
GPFM115-12G GPFM115-12G GPFM115-12G
GPFM115-24G GPFM115-24G GPFM115-24G
GPFM115-48G GPFM115-48G GPFM115-48G
GPFM115-28G GPFM115-28G GPFM115-28G
GPFM115-48 GPFM115-48 GPFM115-48
GPFM115-5 GPFM115-5 GPFM115-5
GPFM115-15 GPFM115-15 GPFM115-15
GPFM115-24 GPFM115-24 GPFM115-24
GPFM115-28 GPFM115-28 GPFM115-28
GPFM115-15G GPFM115-15G GPFM115-15G
GPFM115-24CG GPFM115-24CG GPFM115-24CG
GPFM115-12 GPFM115-12 GPFM115-12
PDF Datasheet Preview
GLOBAL PERFORMANCE SWITCHERS

FEATURES:
• 115 Watts of continuous power with forced air
• Power factor corrected
• 74-81% efficiency
• Small package x inches
• Power fail warning, remote sense
• Optional cover with cooling fan
• Medical Approval to UL2601-1, CSA-C22.2

No. EN60601-1
• RoHS Compliant Model Available G suffix

GPFM115 Medical
115 Watt Global Performance Switchers

DC Power Supplies

SPECIFICATIONS

Ac Input 85-264 Vac, 47-63 Hz single phase

Output Power Continuous rating is 80 W with unrestricted natural convection, or 115 W with forced convection. All models capable of 110% of rated power for 60 sec., 10% duty cycle maximum.

Input Current Maximum input current at 90 Vac, 60 Hz with full rated load is A. Input current harmonic content meets the requirements of IEC1000-3-2 for all load conditions at 230 Vac input. Active input circuitry provides high power factor of min, typical.

Inrush Current Inrush 240 Vac is less than 37 A, averaged over thr first ac halfcycle under cold start conditions. Limiting provided by internal thermistors.

Holdup Time 25 ms minimum from loss of ac input at full load.

Power Fail TTL / CMOS compatible output goes low V 8 ms before output voltage drops more than 4% below nominal voltage upon loss of ac power. The signal is factory set to trip before there is insufficient power stored in the primary to sustain the output. Signal can sink mA or source 400 uA at V Fan-out =

Efficiency 74 to 81% depending upon model

DC Output Specification Total regulation is the maximum deviation from the nominal voltage for all steady state loading conditions. Peak ratings are for 60 s maximum duration, 10% duty cycle. Consult factory for application assistance.

Remote Sense Provided as a standard feature on all models. Capable of compensating for V total of cabling losses.

Overload Protection Fully protected against short circuit and output overload. Short circuit protection is cycling type power limit. Recovery after fault is automatic. Consult factory for specific condition limits.

Overvoltage Protection Built in on all models - See voltage and current chart for individual model output limits. When OVP fires, the output converter stops providing input power to output. Output voltage decay is dependent upon loading.

Output Noise rms, 1% pk-pk, 20 MHz Bandwidth, differential mode. Measured with noise probe directly across output terminals of the power supply.

Transient Response Main Output 500 us typical response time for return to within of final value for a 50% load step change, A/us. Maximum voltage deviation is

Minimum Load No minimum load required to maintain output specifications. An abrupt change in output current from > 90% to < 2% load may cause a false triggering of the power fail signal.

Voltage Adjustment Main output

Temperature Coefficient 0.03%/°C typical on all outputs.

Thermal Shutdown Provided as a standard feature. Designed to protect unit from prolonged over temperature.

Fan Output An additional 12 Vdc nominal V , 100 mA output suitable for powering a dc fan is included in all models. The fan output is referenced to +out. Due to high pk-pk noise and low regulation, it is not recommended that this output be used for any other purpose.

Input Protection Internal ac fuse provided on all models. Fuse does not blow on overload or short circuit -- fuse blows only if a catastrophic failure occurs in the unit.

EMI/EMC Compliance All models include built-in EMI filtering to meet the following emissions requirements:

EMI SPECIFICATIONS

COMPLIANCE LEVEL

Conducted Emissions Static Discharge RF Field Susceptibility Fast Transients/Bursts Surge Susceptibility Line Frequency Harmonics Conducted RF Susceptibility Voltage Dips and Interruptions

EN55011 Class B FCC Class B EN61000-4-2, 6 kV contact, 8 kV air EN61000-4-3, 3 V/meter EN61000-4-4, 2 kV, 5 kHz EN61000-4-5, 1 kV diff., 2 kV com. EN61000-3-2 Class A EN61000-4-6, 3 V EN61000-4-11, Consult factory for more details.

Leakage Current 90 uA normal conditions 132 Vac 60 Hz input or 250 uA 264 Vac single fault.

Medical Safety All models are Certified to be in compliance with the applicable requirements of UL 2601, CSA No. 601.1-M90, IEC 601-1 1988 , EN 60601-1 Consult factory for approval status

All specifications are typical at nominal input, full load at 25OC unless otherwise stated

Medical Model GPFM115-5 GPFM115-12 GPFM115-13 GPFM115-15 GPFM115-24 GPFM115-28 GPFM115-48

RoHS Suffix*

Voltage Output

V 12 V 13 V 15 V 24 V 28 V 48 V

Output Adjustment
±5% ±5% ±5% ±5% ±5% ±5% ±5%