GPFC160 Commercial 160 Watt Global Performance Switchers

FEATURES:
• watts/cu.in. power density
• Compact size x meets 1U height
• Power factor corrected to IEC 1000-3-2 Class A
• Less than 300 µA leakage
• EMI compliance to CISPR22, FCC Class B
• Commercial Approved to UL1950, IEC950, EN60950 and CSA No. 950
• 2-year warranty
marked to LVD

SPECIFICATIONS:

Ac Input 85-264 Vac, 47-63 Hz single phase.

Input Current Maximum input current A at 90 Vac, 60 Hz with full rated load. Input current harmonic content meets the requirements of IEC1000-3-2.

Hold-upTime 25 ms minimum from loss of ac input at full load, nominal line 115 Vac .

Output Power Total regulation is the maximum deviation from the nominal voltage for all steady-state loading conditions. Each individual output is to be used within its specified limits of that output. Peak ratings are for 60 s maximum duration, 10% duty cycle.

Overload Protection Fully protected against short circuit and output overload. Short circuit protection is cycling type power limit. Recovery after fault is automatic.

Output Noise rms, 1% pk-pk, 20 MHz Bandwidth, differential mode. Measured with noise probe directly across output terminals of the power supply.

Transient Response 500 ms typical response time for return to within of final value for a 50% load step change, A/ms. Maximum voltage deviation is

Remote Sense Provided as a standard feature. Capable of compensating for V total of cabling losses.

Overvoltage Protection Built in on all models. OVP crowbar reduces output voltage below nominal rating in less than 50 ms.

Voltage Adjustment Main output

Input Protection Internal ac fuse provided on all models. Fuse does not blow on overload or short blows only if
catastrophic failure occurs in the unit.

Inrush Current Inrush 240 Vac is less than 37 A, averaged over the first ac half-cycle under cold start conditions. Limiting provided by internal thermistors.

Fan Output An additional 12 Vdc, 250 mA output suitable for powering a dc fan is included in all models. The output is protected by an internal PTC in the event of an overload.

Thermal Shutdown Provided as a standard feature. Designed to protect the unit from prolonged over temperature.

Power Fail TTL or CMOS compatible output goes low V 8 ms before output voltage drops more than 4% below nominal voltage upon loss of ac power. The signal is factory set to trip when input power can no longer sustain the output.

Temperature Coefficient 0.03%/°C typical on all outputs.

EMI/EMC Compliance

All models include built-in EMI filtering to meet the
following emissions requirements:

EMI SPECIFICATIONS

COMPLIANCE LEVEL

Conducted Emissions

EN55022 Class B FCC Class B

Static Discharge

EN61000-4-2, 6 kV contact, 8 kV air

RF Field Susceptibility

EN61000-4-3, 3 V/meter

Fast Transients/Bursts

EN61000-4-4, 2 kV, 5 kHz