GPFC125 Commercial/GPFM125 Medical 125 Watt Global Performance Switchers
Part | Datasheet |
---|---|
![]() |
GPFC125AG (pdf) |
Related Parts | Information |
---|---|
![]() |
GPFC125A |
![]() |
GPFC125H |
![]() |
GPFC125G |
![]() |
GPFC125D |
![]() |
GPFC125B |
![]() |
GPFC125BG |
![]() |
GPFC125F |
![]() |
GPFC125GG |
PDF Datasheet Preview |
---|
GPFC125 Commercial/GPFM125 Medical 125 Watt Global Performance Switchers SPECIFICATIONS: Ac Input 90-264 Vac, 47-63 Hz single phase. Input Current Maximum input current 2A at 90 Vac, 60 Hz with full rated load. Input current harmonic content meets the requirements of IEC1000-3-2. Active circuitry provides high power factor as listed at min., typical. All data taken with full output loading. DC Output Power 125 W with 150 LFM of air, 50 W convection cooled, 80 W convection cooled with unit mounted to min. 12 x 12 x in. thick aluminim plate. Peak ratings are for 60 s maximum duration, 10% duty cycle. With optional cover installed,125 W, 200 LFM airflow is required -C suffix . Inrush Current Inrush 240 Vac is less than 37 A, averaged over the first ac half-cycle under cold start conditions. Limiting provided by internal thermistors. Input Protection Internal ac fuse provided on all models. Fuse does not blow on overload or short circuit fuse blows only if a catastrophic failure occurs in the unit. Efficiency 72 to 85% at full rated load. Depending upon model and load distribution. Minimum Load Supply will function with no load on any output. To maintain regulation with full load on V2, 3 and 4 output V1 requires a minimum load of 2A + V4 current . Lower minimum load may be obtained if less then full load is drawn from auxiliary outputs. Overload Protection Fully protected against short circuit and output overload. Total output power limited to approximately 150 Watts. Cycling type limits on output 1, 2 & 3, linear fold back on output Recovery after fault is automatic. Overvoltage Protection Built in on all models - See Output table for individual model output limits. Output Noise rms, 1% pk-pk, 20 MHz Bandwidth, differential mode. Transient Response 500 ms typical response time for return to within of final value for a 50% load step change, A ms. Maximum voltage deviation is Temperature Coefficient / °C typical on all outputs. FEATURES: • Compact 125 watt multiple output • Power density of 4 watts per cubic inch • Power Factor Correction to meet EN61000-3-2 • Small package x inches • Conducted EMI exceeds FCC Class B and CISPR 22 Class B Commercial models and CISPR 11 Class B Medical models • Commercial approved to UL1950, IEC950, CSA22.2 No. 950 and EN60950. • Medical approved to UL2601-1, IEC601-1, CSA22.2 No. EN60601-1 marked to LVD Remote Sense Provided as a standard feature on V1 of all models. Temperature Range 0 to 50 °C at full rated output power. For operation above 50 °C, derate output power and current by % per °C. Altitude Operating: -500 to 10,000 ft. MSL Non-Operating -500 to 40,000 ft MSL Shock and Vibration All models are designed to meet the following specifications; Random Vibration - Operating g2/Hz, grms overall, 3 axes, 10 min. / axis Non-Operating g2/Hz, grms overall, 3 axes, 1 hr. / axis Shock - Operating Half-sine, 20 gpk, 10 ms, 3 axes, 6 shocks total Non-Operating Half-sine, 40 gpk, 10 ms, 3 axes, 6 shocks total EMI/EMC Compliance All models include built-in EMI filtering to meet the EMC requirements below. EMI SPECIFICATIONS COMPLIANCE LEVEL Conducted Emissions-GPFC125 Conducted Emissions-GPFM125 Static Discharge RF Field Susceptibility Fast Transients / Bursts Surge Susceptibility Conducted RF Susceptibility Voltage Sags & Surges Line Frequency Harmonics EN55022, Class B FCC Class B EN55011,Class B FCC Class B EN61000-4-2, 6 kV contact 8 kV air EN61000-4-3, 3V/meter EN61000-4-4, 2 kV, 5 kHz EN61000-4-5, 1 kV diff., 2 kV com. EN61000-4-6, 3V EN61000-4-11 EN61000-3-2 Class A Commercial Safety Approvals All models are approved to UL1950, CSA22.2 No. 950-95, IEC950, EN60950. CB certificate available. Exceeds FCC and CISPR22 Class B conducted emissions requirement Medical Safety Approvals All models are Certified to be in compliance with the applicable requirements of UL2601, CSA No. 601.1-M90, IEC 601-1 1988 , EN 60601-1 CB certificate available. Leakage Current |
More datasheets: CY28411OXC-1 | CY28411OXC-1T | CY28411ZXC-1 | GPFC125A | GPFC125H | GPFC125G | GPFC125D | GPFC125B | GPFC125BG | GPFC125F |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived GPFC125AG Datasheet file may be downloaded here without warranties.