GPFC110-15G

GPFC110-15G Datasheet


GPFC110 Commercial

Part Datasheet
GPFC110-15G GPFC110-15G GPFC110-15G (pdf)
Related Parts Information
GPFC110-15 GPFC110-15 GPFC110-15
GPFC110-24 GPFC110-24 GPFC110-24
GPFC110-48 GPFC110-48 GPFC110-48
GPFC110-12 GPFC110-12 GPFC110-12
GPFC110-28 GPFC110-28 GPFC110-28
GPFC110-5 GPFC110-5 GPFC110-5
GPFC110-48G GPFC110-48G GPFC110-48G
GPFC110-12G GPFC110-12G GPFC110-12G
GPFC110-28G GPFC110-28G GPFC110-28G
GPFC110-5G GPFC110-5G GPFC110-5G
GPFC110-24G GPFC110-24G GPFC110-24G
PDF Datasheet Preview
110 WATT GLOBAL PERFORMANCE SWITCHERS

FEATURES:
• watts/cu.in. power density
• Compact size x
meets 1U height
• Power factor corrected to IEC 1000-3-2 Class A
• Less than 300 uA leakage
• EMI compliance to CISPR 22, FCC Class B
• Approved to UL1950, IEC950 and

CSA No. 950
• 2-year warranty
• marked to LVD
• RoHS Compliant Model Available G suffix

GPFC110 Commercial
110 Watt Global Performance Switchers

SPECIFICATIONS

Ac Input 85-264 Vac, 47-63 Hz single phase.

Input Current Maximum input current A at 90 Vac, 60 Hz with full rated load. Input current harmonic content meets the requirements of IEC1000-3-2.

Hold-up Time 25 ms minimum from loss of ac input at full load, nominal line 115 Vac .

Output Power 110 W fan cooled, 75 W convection. Peak ratings are for 60 s maximum duration, 10% duty cycle.

Total Regulation Total regulation is the maximum deviation from the nominal voltage for all steady-state loading conditions.

Overload Protection Fully protected against short circuit and output overload. Short circuit protection is cycling type power limit. Recovery after fault is automatic.

Output Noise rms, 1% pk-pk, 20 MHz Bandwidth, differential mode. Measured with noise probe directly across output terminals of the power supply.

Transient Response 500 us typical response time for return to within of final value for a 50% load step change, t< A/us. Maximum voltage deviation is Load must not go below stated minimum.

Remote Sense Provided as a standard feature. Capable of compensating for V total of cabling losses in voltage. Open sense lead protection.

Overvoltage Protection OVP crowbar reduces output voltage below nominal rating in less than 50 ms.

Voltage Adjustment Main output

Input Protection Internal ac fuse provided on all models. Fuse does not blow on overload or short blows only if catastrophic failure occurs in the unit.

EMI/EMC Compliance All models include built-in EMI filtering to meet the EMC requirements below.

EMI SPECIFICATIONS

Conducted Emissions Static Discharge RF Field Susceptibility Fast Transients/Bursts Surge Susceptibility Line Frequency Harmonics

COMPLIANCE LEVEL

EN55022 Class B FCC Class B EN61000-4-2, 6 kV contact, 8 kV air EN61000-4-3, 3 V/meter EN61000-4-4, 2 kV, 5 kHz EN61000-4-5, 1 kV diff., 2 kV com. EN61000-3-2 Class A

Inrush Current Inrush 240 Vac is less than 37 A, averaged over the first ac half-cycle under cold start conditions. Limiting provided by internal thermistors.

Fan Output An additional output, same as Vout, suitable for powering a dc fan is included in all models. The output is protected by an internal resistor in the event of an overload.

Power Fail TTL or CMOS compatible output goes low V 8 ms before output voltage drops more than 4% below nominal voltage upon loss of ac power. The signal is factory set to trip when input power can no longer sustain the output.

Temperature Coefficient 0.03%/°C typical on all outputs.

Environmental Designed for 0 to 50°C operation at full rated output power derate output current and total output power by per °C above 50°C. See Environmental and Packaging Specifications on the next page.

Commercial Safety Approvals All models are approved to UL1950, CSA22.2 No. 950-95, IEC950, EN60950. CB certificate available. Exceeds FCC and CISPR22 Class B conducted emissions requirement

All specifications are typical at nominal input, full load at 25OC unless otherwise stated

Commercial Model GPFC 110-5 GPFC 110-12 GPFC 110-15 GPFC 110-24 GPFC110-28 GPFC110-48

Output No. 1

Output v 12 V 15 V 24 V 28 V 48 V

Output Minimum A

Output Maximum A

Output Maximum B

Notes A. With unrestricted convection cooling. B. With 26cfm airflow. C. Add “G” suffix to part number for RoHS compliant model.

Total Regulation
2% 2% 2% 2% 2% 2%
More datasheets: 74AC251MTCX | ADG508ATCHIPS | TSWA3NC LFS | CPTS-ANT-HG | GPFC110-15 | GPFC110-24 | GPFC110-48 | GPFC110-12 | GPFC110-28 | GPFC110-5


Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived GPFC110-15G Datasheet file may be downloaded here without warranties.

Datasheet ID: GPFC110-15G 506323