Summary
• Ultra small x
• Wide-range ac input 85-264 Vac
• 2-year warranty
• Conducted EMI exceeds FCC Class B and CISPR
22 Class B Commercial models and CISPR 11 Class B Medical models
• Commercial Approved to UL1950, IEC950, EN60950 and CSA22.2-234 L3
• Medical Approved to UL2601-1, IEC601-1 and CSA22.2 No. 601
• RoHS Compliant G suffix
• marked to LVD

DC Power Supplies

SPECIFICATIONS

Ac Input 85-264 Vac, 47-63 Hz single phase.

Input Current Maximum input current at 120 Vac, 60 Hz with full rated output load A

Hold-Up Time 20 ms minimum from loss of ac input at full load, nominal line 115 Vac .

Output Power 40 W continuous, 50 W peak. Peak ratings are for 60 s maximum duration, 10% duty cycle. During peak load condition, output regulation may exceed total regulation limits.

Overload Protection Fully protected against short circuit and output overload. Short circuit protection is cycling type power limit. Recovery after fault is automatic. Factory set to begin power limiting at approximately 55 W. See output ratings chart for additional notes or conditions.

Overvoltage Protection. See output ratings chart.

Efficiency 69-77% at full rated load, nominal input voltage, depending on model.

Turn-on Time Less than 1 s at 120 Vac, 25°C inversely proportional to input voltage .

Input Protection Requires external ac line fusing. A, 250 V rated fuse with I2t > 20 is recommended.

Inrush Current Inrush is limited by internal thermistor. Inrush at 240 Vac under cold start conditions will not exceed 34 A.

Temperature Coefficient 0.03%/°C typical on all outputs.

Environmental Designed for 0 to 50°C operation at full rated output power derate output current and total output power by per °C above 50°C. See Environmental and Packaging Specifications on next page.

Output Noise rms, 1% pk-pk, 20 MHz bandwidth, differential mode. Measured with noise probe directly across output terminals of the power supply.

Transient Response Main us typical response time for return to within of final value for a 50% load step change. A/us. Maximum voltage deviation is Startup/ shutdown overshoot less than

EMI/EMC Compliance All models include built-in EMI filtering to meet the following emissions requirements:

EMI SPECIFICATIONS

COMPLIANCE LEVEL

Conducted Emissions GPC41 Conducted Emissions GPM41 Static Discharge RF Field Susceptibility Fast Transients/Bursts Surge Susceptibility

EN55022 Class B FCC Class B EN55011 Class B FCC Class B EN61000-4-2, 6 kV contact, 8 kV air EN61000-4-3, 3 V/meter EN61000-4-4, 2 kV, 5 kH EN61000-4-5, 1 kV diff., 2 kV com.

Commercial Leakage Current 60 uA single fault 60 Hz input.

Commercial Safety Approved to UL1950, CSA22.2 No. 234 Level 3, IEC950 and EN60950. UL file #E135803 commercial CSA #LR46516 all models. All dc outputs are SELV under normal and single fault conditions.

Medical Leakage Current 35 uA , 254 Vac 60 Hz input.

Medical Safety Approved to UL2601, CSA22.2 No. 601 Level 3, IEC601. UL file E116994 CSA #LR46516. The output s are intended for safety earthed Signal Output and Intermediate Circuits only. The output s are not acceptable for patient connection without additional isolation. All dc outputs are SELV under normal and single fault conditions.

All specifications are typical at nominal input, full load at 25OC unless otherwise stated

Commercial Model

Medical Model

Output

Current

GPC41-5

GPM41-5

GPC41-12

GPM41-12

GPC41-15
More datasheets: GPM41-5 | GPM41-12 | GPM41-24 | GPM41-28 | GPC41-5G | GPC41-28G | GPC41-48G | GPC41-24G | GPC41-12G | GPC41-15G