GPC225-24G

GPC225-24G Datasheet


GPC225 Commercial/GPM225 Medical 225 Watt Global Performance Switchers

Part Datasheet
GPC225-24G GPC225-24G GPC225-24G (pdf)
Related Parts Information
GPC225-28G GPC225-28G GPC225-28G
GPC225-5 GPC225-5 GPC225-5
GPC225-28 GPC225-28 GPC225-28
GPC225-12 GPC225-12 GPC225-12
GPC225-24 GPC225-24 GPC225-24
GPC225-5G GPC225-5G GPC225-5G
GPC225-15G GPC225-15G GPC225-15G
GPC225-12G GPC225-12G GPC225-12G
PDF Datasheet Preview
GPC225 Commercial/GPM225 Medical 225 Watt Global Performance Switchers

FEATURES:
• Wide-range ac input 85-264 Vac
• 2-year warranty
• Conducted EMI exceeds FCC Class B and CISPR 22

Class B Commercial models and CISPR 11 Class B Medical models
• Commercial Approved to UL1950, IEC950 and CSA22.2-234 L3
• Medical Approved to UL2601-1, IEC601-1 and CSA22.2 No. 601
• marked to LVD

SPECIFICATIONS:

Ac Input 85-264 Vac, 47-63 Hz single phase.

Input Current Maximum input current at 120 Vac, 60 Hz with full rated output load A

Hold-Up Time 20 ms minimum from loss of ac input at full load, nominal line 115 Vac .

Output Power 175 W convection 225 W with 26 cfm air 250 W peak. Peak ratings are for 60 s maximum duration, 10% duty cycle.

Overload Protection Fully protected against short circuit and output overload. Short circuit protection is cycling type power limit. Recovery after fault is automatic. Factory set to begin power limiting at approximately 250 W.

Overvoltage Protection 124% ± 12% typical.

Efficiency 70% at full rated load, nominal input voltage, depending on model and load distribution.

Input Protection Internal ac fuse provided. Designed to blow only if a catastrophic failure occurs in the unit.

Inrush Current Inrush is limited by internal thermistors. Inrush at 240 Vac under cold start conditions will not exceed 60 A.

Temperature Coefficient 0.03%/°C typical on all outputs.

Thermal Shutdown Provided as a standard feature. Designed to protect unit from prolonged over temperature.

Environmental Designed for 0 to 50°C operation at full rated output power derate output current and total output power by per °C above 50°C. See Environmental and Packaging Specifications on next page.

Power Fail TTL- or CMOS-compatible output goes low < V 5 ms before output voltage drops more than 4% below nominal voltage upon loss of ac power. The signal is factory set to trip on 84 to 94 Vac brown-out depending upon incoming
line impedance and distortion. Other settings are available to the user through adjustment of built-in potentiometer.

Output Noise rms, 1% pk-pk, 20 MHz bandwidth, differential mode. Measured with noise probe directly across output terminals of the power supply.

Transient Response 500 µs typical response time for return to within of final value for a 50% load step change. A/µs. Maximum voltage deviation is Startup/shutdown overshoot less than

Remote Sense Provided as a standard feature.

Voltage Adjustment Built-in potentiometer adjusts voltage

EMI/EMC Compliance

All models include built-in EMI filtering to meet the
following emissions requirements:

EMI SPECIFICATIONS

COMPLIANCE LEVEL

Conducted Emissions GPC225 EN55022 Class B FCC Class B

Conducted Emissions GPM225 EN55011 Class B FCC Class B

Static Discharge

EN61000-4-2, 6 kV contact, 8 kV air

RF Field Susceptibility

EN61000-4-3, 3 V/meter

Fast Transients/Bursts

EN61000-4-4, 2 kV, 5 kHz

Surge Susceptibility

EN61000-4-5, 1 kV diff., 2 kV com.

Commercial Leakage Current mA 254 Vac 60 Hz input with no deviations .

Commercial Safety Approved to UL1950, CSA22.2 No. 234 Level 3, IEC950, EN60950 and CISPR22. UL file #E135803 commercial CSA #LR46516. The output s are intended for safety earthed Signal Output and Intermediate Circuits only. All dc outputs are SELV under normal and single fault conditions.

Medical Leakage Current 60 µA. 254 Vac 60Hz input.
More datasheets: DFR0316 | FQPF6N80 | GPC225-28G | GPC225-5 | GPC225-28 | GPC225-12 | GPC225-24 | GPC225-5G | GPC225-15G | GPC225-12G


Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived GPC225-24G Datasheet file may be downloaded here without warranties.

Datasheet ID: GPC225-24G 506317