GPC200 Commercial/GPM200 Medical 200 Watt Global Performance Switchers

FEATURES:
• Wide-range ac input 85-264 Vac
• 2-year warranty
• Conducted EMI exceeds FCC Class B and CISPR 22

Class B Commercial models and CISPR 11 Class B Medical models
• Commercial Approved to UL1950, IEC950 and CSA22.2-234 L3
• Medical Approved to UL2601-1, IEC601-1 and CSA22.2 No. 601
• Multiple outputs
• marked to LVD

SPECIFICATIONS:

Ac Input 85-264 Vac, 47-63 Hz single phase.

Input Current Maximum input current at 120 Vac, 60 Hz with full rated output load A

Hold-Up Time 20 ms minimum from loss of ac input at full load, nominal line 115 Vac .

Output Power 150 W convection 200 with 26 cfm air 220 W peak. Peak ratings are for 60 s maximum duration, 10% duty cycle. During peak load condition, output regulation may exceed total regulation limits.

Overload Protection Fully protected against short circuit and output overload. Short circuit protection is cycling type power limit on outputs 1 & 2 foldback type on outputs 3 & Recovery after fault is automatic. See output ratings chart for additional notes or conditions.

Overvoltage Protection Main outputs 124% ± 12% typical.

Efficiency Minimum 65% at full rated load, nominal input voltage, depending on model and load distribution.

Input Protection Internal ac fuse provided. Designed to blow only if a catastrophic failure occurs in the unit.

Inrush Current Inrush is limited by internal thermistors. Inrush at 240 Vac under cold start conditions will not exceed 60 A.

Temperature Coefficient 0.03%/°C typical on all outputs.

Thermal Shutdown Provided as a standard feature. Designed to protect unit from prolonged overtemperature.

Environmental Designed for 0 to 50°C operation at full rated output power derate output current and total output power by per °C above 50°C. See Environmental and Packaging Specifications on next page.

Power Fail TTL- or CMOS-compatible output goes low < V 5 ms
before output voltage drops more than 4% below nominal voltage upon loss of ac power.The signal is factory set to trip on 84 to 94 Vac brown-out depending upon incoming line impedance and distortion. Other settings are available to the user through adjustment of built-in potentiometer.

Output Noise rms, 1% pk-pk, 20 MHz bandwidth, differential mode. Measured with noise probe directly across output terminals of the power supply.

Transient Response

Main µs typical response time for return to within of final value for a 50% load step change. A/µs. Maximum voltage deviation is Startup/shutdown overshoot
less than

Remote Sense Provided as a standard feature on main 5 V output.

Voltage Adjustment Built-in potentiometer adjusts voltage ±5% on output 1 &

EMI/EMC Compliance

All models include built-in EMI filtering to meet the following
emissions requirements:

EMI SPECIFICATIONS

COMPLIANCE LEVEL

Conducted Emissions GPC200 EN55022 Class B FCC Class B

Conducted Emissions GPM200 EN55011 Class B FCC Class B

Static Discharge

EN61000-4-2, 6 kV contact, 8 kV air

RF Field Susceptibility

EN61000-4-3, 3 V/meter

Fast Transients/Bursts

EN61000-4-4, 2 kV, 5 kHz

Surge Susceptibility

EN61000-4-5, 1 kV diff., 2 kV com.

Commercial Leakage Current mA 254 Vac 60 Hz input with no deviations .