GLD140AG

GLD140AG Datasheet


GLD140 Gold Performance Medical Switchers 140 Watt Multiple Output

Part Datasheet
GLD140AG GLD140AG GLD140AG (pdf)
Related Parts Information
GLD140DG GLD140DG GLD140DG
GLD140D GLD140D GLD140D
GLD140HG GLD140HG GLD140HG
PDF Datasheet Preview
GLD140 Gold Performance Medical Switchers 140 Watt Multiple Output

FEATURES:
• Compact size x
• Power factor corrected to IEC 1000-3-2 Class A
• Documented FMEA, WCA and EMC test results
• EMI compliance to CISPR11, FCC Class B, IEC601-1-2
• Approved to UL2601, IEC601-1 and

CSA No. 601.1-M90 and EN60601 1990
• marked to LVD

SPECIFICATIONS:

Ac Input 90-264 Vac, 47-63 Hz single phase. Output Power Continuous output power 140 W with unrestricted convection cooling, 180 W with 150 LFM of air. Input Current Active Power Factor Correction circuitry assures compliance with IEC1000-3-2, Class A. Maximum input current at minimum input voltage and full load is A. Efficiency 73 85 % at full rated load, nominal input voltage, depending on model and load distribution. Hold-up Time 26 ms total. 16 ms minimum from loss of ac input at full load until activation of the power fail signal. Output voltages remain within specified regulation limits for an additional 9 ms minimum after power fail activates. Overload Protection Fully protected against short circuit and output overload. Short circuit protection is cycling type power limit. Output Noise rms, 1% pk-pk, 20 MHz Bandwidth, differential mode. Measured with noise probe directly across output terminals of the power supply. Transient Response 500 µs typical response time for return to within of final value for a 45% load step from any load greater than 10% of full rated load, A µs. Maximum voltage deviation is Remote Sense Provided as a standard feature on V1 and V2. Overvoltage Protection Built in on V1, 2 and 3 outputs. Voltage Adjustment Factory set to specified voltage with user adjustable potentiometer on V1, 2 and User can adjust V1, 2 and 3 at least ±5% of nominal output voltage. Output Regulation for all outputs is the maximum deviation from initial set point under all line and load conditions. Initial set tolerance is measured with all outputs at 50 % of full rated load. No Load Turn-On/Standby A minimum load of 3 A on V1 is required for proper regulation. If not met, no degradation of reliability will occur. Temperature Coefficient / °C typical on all outputs. Input Protection Internal ac fuses provided on both lines on all units. Inrush Current Inrush is limited by internal thermistors. The inrush at 240 Vac, averaged over the first ac half-cycle under cold start conditions will not exceed 37 A.

Thermal Shutdown Provided as a standard feature. Designed to protect unit from prolonged over temperature. Power Fail TTL / CMOS compatible output goes low V 10 ms before output voltage drops more than 4% below nominal voltage upon loss of ac power. Power Good TTL / CMOS compatible output rises high 100 to 300 ms after V1 reaches regulation and should assure that sufficient energy is stored in the input section to provide normal power fail / shutdown. Inhibit signal when pulled to the V1 output common will inhibit all output voltages. Fan Output An additional thermally controlled 12 Vdc, 250 mA output suitable for powering a dc fan is included in all models Factory installed cover with fan makes this output unavailable . EMI/EMC Compliance All models include built-in EMI filtering to meet the following requirements:

EMC SPECIFICATION

COMPLIANCE LEVEL

Conducted Emissions

EN55011, Class B FCC Class B

Static Discharge

EN61000-4-2, 6 kV contact 8 kV air

RF Field Susceptibility

EN61000-4-3, 3V/meter

Fast Transients / Bursts

EN61000-4-4, 2 kV, 5 kHz

Surge Susceptibility

EN61000-4-5, 1 kV diff., 2 kV com.

Conducted RF Susceptibility EN61000-4-6, 3V

Voltage Sags & Surges

EN61000-4-11

Line Frequency Harmonics EN61000-3-2 Class A

Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033
800-235-5929
• 805-486-4565
• FAX 805-487-8911


GLD140 Medical Switchers 140 Watt Multiple Output

Medical Model

Output No.

Output Voltage

Output Current A

Output Current B

Set Tolerance

GLD140A
+12 V
12 V C
-12 V
16 A 6A 4A A
20 A 8A 5A A
1% 1% 1%

GLD140B
+12 V