GLC65-48G

GLC65-48G Datasheet


GLC65 Commercial/GLM65 Medical

Part Datasheet
GLC65-48G GLC65-48G GLC65-48G (pdf)
Related Parts Information
GLC65-28 GLC65-28 GLC65-28
GLM65-28 GLM65-28 GLM65-28
GLC65-48 GLC65-48 GLC65-48
GLC65-24 GLC65-24 GLC65-24
GLC65-15 GLC65-15 GLC65-15
GLC65-12 GLC65-12 GLC65-12
GLM65-5 GLM65-5 GLM65-5
GLM65-48 GLM65-48 GLM65-48
GLM65-15 GLM65-15 GLM65-15
GLC65-5 GLC65-5 GLC65-5
GLM65-24 GLM65-24 GLM65-24
GLM65-12 GLM65-12 GLM65-12
GLC65-5G GLC65-5G GLC65-5G
GLC65-28G GLC65-28G GLC65-28G
GLC65-24G GLC65-24G GLC65-24G
GLC65-15G GLC65-15G GLC65-15G
GLC65-12G GLC65-12G GLC65-12G
GLM65-5G GLM65-5G GLM65-5G
GLM65-28G GLM65-28G GLM65-28G
GLM65-24G GLM65-24G GLM65-24G
GLM65-15G GLM65-15G GLM65-15G
GLM65-12G GLM65-12G GLM65-12G
PDF Datasheet Preview
GLC65 Commercial/GLM65 Medical
65 Watt Single Output Global Performance Switchers

GLOBAL PERFORMANCE SWITCHERS

FEATURES:
• W/in3
• Compact x
• Ultra-high efficiency up to 94% using patented
technology
• Meets harmonic requirements of IEC1000-3-2, Class A
• Conducted EMI exceeds FCC Class B and CISPR 22

Class B Commercial models and CISPR 11 Class B Medical models
• 2-year warranty
• Exempt from line harmonics standard EN61000-3-2
• Commercial Approved to UL1950, IEC950, EN60950, CSA22.2 No. 950
• Medical Approved to UL2601, EN60601, CSA22.2 No.
• Multiple output versions also available
• RoHS models available G suffix
• marked to LVD

SPECIFICATIONS

Ac Input 90-264 Vac, 47-63 Hz single phase.

Input Current Maximum input current at minimum output voltage and output overload will be less than A. Meets input current harmonic requirements of IEC1000-3-2.

Inrush Current Inrush is limited by internal thermistor. The inrush at 240 Vac, averaged over the first ac half-cycle under cold start conditions will not exceed 37A.

EMI/EMC Compliance All models include built-in EMI filtering to meet the following emissions requirements:

Output Power Normal continuous output power is 65 W, 75 W peak for 60 s. The Vdc unit is W and the 5 Vdc unit is 55 W continuous.

Hold-Up Time 20 ms from loss of ac input at 65 W load, from 120 Vac input.

Overload Protection Fully protected against short circuit and output overload. Short circuit protection is cycling type power limit.

Output Noise rms, 1% pk-pk, 20 MHz bandwidth, differential mode. Measured with scope probe directly across output terminals of the power supply with load terminated with uF capacitor.

Transient Response Main output 500 us typical response time for return to within of final value for a 50% load step within the regulation limits of minimum and maximum load, A/us. Maximum voltage deviation is Startup/shutdown overshoot less than

Voltage Adjustment Adjustable potentiometer capable of ±5% change from nominal setting.

Efficiency 82 to 94% minimum at full rated load, nominal input voltage, depending on model.

EMI SPECIFICATIONS

Conducted Emissions GLC65 Conducted Emissions GLM65 Static Discharge RF Field Susceptibility Fast Transients/Bursts Surge Susceptibility

COMPLIANCE LEVEL

EN55022 Class B FCC Class B EN55011 Class B FCC Class B EN61000-4-2, 6 kV contact, 8 kV air EN61000-4-3, 3 V/meter EN61000-4-4, 2 kV, 5 kHz EN61000-4-5, 1 kV diff., 2 kV com.

Commercial Leakage Current Under normal conditions, leakage current is 425 uA with 132 Vac 60 Hz input.

Commercial Safety All GLC models are approved to UL1950, CSA22.2 No. 950, IEC950 and EN60950.

Medical Leakage Current The maximum leakage current under single-fault conditions 254 Vac 50 Hz is 120 uA. Under normal conditions, leakage current is 31uA with 132 Vac 60 Hz input.

Medical Safety All GLM models are approved to UL2601, CSA22.2 No. 601, IEC601-1 and EN60601. Consult factory for approval status.

Temperature Coefficient 0.03%°C typical on all outputs.

Remote Sense Provided as standard feature on all models. Includes open sense protection.

Minimum Load No minimum load required.

All specifications are typical at nominal input, full load at 25OC unless otherwise stated

Commercial Model GLC65-5 GLC65-12 GLC65-15 GLC65-18 GLC65-20 GLC65-24 GLC65-28 GLC65-48

Medical Model GLM65-5 GLM65-12 GLM65-15 GLM65-18 GLM65-20 GLM65-24 GLM65-28 GLM65-48

Output

V 12 V 15 V 18 V 20V 24 V 28 V 48 V

Current
9/11 A * A

Total Regulation
2% 2% 2% 2% 2% 2% 2% 2%
• Note:
More datasheets: GLC65-24 | GLC65-15 | GLC65-12 | GLM65-5 | GLM65-48 | GLM65-15 | GLC65-5 | GLM65-24 | GLM65-12 | GLC65-5G


Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived GLC65-48G Datasheet file may be downloaded here without warranties.

Datasheet ID: GLC65-48G 506304