GLC110 Commercial/GLM110 Medical
Part | Datasheet |
---|---|
![]() |
GLC110-15G (pdf) |
Related Parts | Information |
---|---|
![]() |
GLM110-212 |
![]() |
GLM110-12 |
![]() |
GLC110-12 |
![]() |
GLC110-212 |
![]() |
GLC110-215 |
![]() |
GLC110-24 |
![]() |
GLC110-524 |
![]() |
GLM110-524 |
![]() |
GLC110-28G |
![]() |
GLC110-5G |
![]() |
GLC110-12G |
![]() |
GLC110-212G |
![]() |
GLC110-215G |
![]() |
GLC110-24G |
![]() |
GLC110-524G |
PDF Datasheet Preview |
---|
GLC110 Commercial/GLM110 Medical 110 Watt Global Performance Switchers GLOBAL PERFORMANCE SWITCHERS FEATURES: • Cost-effective power source • Single- and dual-output units • Low height • 2-year warranty • Power fail signal standard • Commercial Approved to UL60950-1, EN60950-1, CSA22.2 No. 950-95 3rd Ed. • Medical Approved to UL2601-1, EN60601-1, CSA-C22.2 No. • Complies with EN61000-3-2 Class A • RoHS Compliant Model Available G suffix SPECIFICATIONS Ac Input 90-264 Vac, 47-63 Hz single phase. Input Current Maximum input current at 90 Vac, 60 Hz with full rated output load not to exceed A. Hold-up Time 20 ms minimum from loss of ac input at full load, nominal line 120 Vac . Output Power Normal continuous output power is 75 W for unrestricted natural convection, or 110 W with 26 cfm air flow. Output Regulation Load regulation on dual output models is measured by ±40% load change from 60% rated load and input voltage change from minimum to maximum ratings. Output #1 requires 1A minimum load for proper regulation of other outputs. Initial set tolerance is measured with all outputs at 60% of full rated load. Load regulation for single-output models measured by changing load from 5% to 50% load or 50% to full load in either direction. Voltage Adjustment Output #1 adjustment is Note output #1 must not be more than 1% below nominal to achieve full output regulation on output High voltage settings may degrade the reliability of the unit due to excessive power dissipation in some outputs. Overload Protection Fully protected against short circuit and output overload. Short circuit protection is cycling type power limit. Factory set to begin power limiting at 120 W. Output Noise rms, 1% pk-pk, 20 MHz bandwidth, differential mode. Measured with noise probe directly across output terminals of the power supply. POWER FAIL Power fail signal is TTL or CMOS compatible output goes low V 5 ms before output voltage drops more than 4% below nominal voltage upon loss of AC power. The signal is factory set to trip on 84 to 94 Vac brown-out depending upon incoming line impedance and distortion. Other settings are available to the user through adjustment of built in potentiometer consult factory for assistance . Output will stay low for 20 ms minimum. Transient Response Main Output 500 us typical response time for return to within of final value for a 50% load step change, A/us. Maximum voltage deviation is Startup/shutdown overshoot less than Turn-On Time less than 1 second at 120 Vac, Overvoltage Protection Built in on main output. Efficiency 72-85% depending on model. Input Protection Internal ac fuse provided on all units. Designed to blow only if a catastrophic failure occurs in the unit. Inrush Current Inrush limited by internal thermistors. Inrush at 240 Vac, averaged over the first ac half-cycle under cold start conditions will not exceed 37 A. Temperature Coefficient 0.03%/°C typical on all outputs. EMI/EMC Compliance All models include built-in EMI filtering to meet the following emissions requirements: EMI SPECIFICATIONS COMPLIANCE LEVEL Conducted Emissions GLC110 Conducted Emissions GLM110 Static Discharge RF Field Susceptibility Fast Transients/Bursts Surge Susceptibility Line Frequency Harmonics EN55022 Class B FCC Class B EN55011 Class B FCC Class B EN61000-4-2, 6 kV contact, 8 kV air EN61000-4-3, 3 V/meter EN61000-4-4, 2 kV, 5 kHz EN61000-4-5, 1 kV diff., 2 kV com. EN61000-3-2 Class A Commercial Safety All GLC models are approved to UL60950-1, CSA22.2 No. 950-95 3rd Ed, and EN60950-1. Medical Safety All GLM models are approved to UL2601-1, CSA-C22.2 No. EN60601-1. All specifications are typical at nominal input, full load at 25OC unless otherwise stated Commercial Model GLC110-212 GLC110-215 GLC110-524 GLC110-12 GLC110-15 GLC110-24 Medical Model GLM110-212 GLM110-215 GLM110-524 GLM110-12 GLM110-15 GLM110-24 |
More datasheets: GLM110-212 | GLM110-12 | GLC110-12 | GLC110-212 | GLC110-215 | GLC110-24 | GLC110-524 | GLM110-524 | GLC110-28G | GLC110-5G |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived GLC110-15G Datasheet file may be downloaded here without warranties.