MLL12-0.25-A MLL15-0.2-A
Part | Datasheet |
---|---|
![]() |
MLL15-0.2-A (pdf) |
Related Parts | Information |
---|---|
![]() |
ML5-1-OV-A |
![]() |
ML12-0.5-A |
![]() |
MTAA-16W-A |
![]() |
MD5-12-OV-A |
![]() |
ML15-0.4-A |
![]() |
MBB524-A |
![]() |
MLL12-0.25-A |
![]() |
MTLL-5W-A |
![]() |
MBB512-A |
PDF Datasheet Preview |
---|
Commercial/Medical International + Linears Commercial Medical • World-wide ac input ranges and safety standards • Industry standard packages • Commercial UL/CSA TUV/IEC models to UL1950 CSA C22.2 No. 950 L3 TUV certified to EN60950 • Burn-in with cycling 3-year warranty • Capacitors have highest CV & ripple current ratings • Medical Approved to UL2601-1, IEC60601-1 and CSA601.1 SPECIFICATIONS: Ac Input 100, 120 and 240 Vac +10%, -13% 215 Vac +12%, -11 % 47 to 63Hz. Tolerance for 230 Vac operation is +15%, Derate output current 10% for 50 Hz operation. Dc Output See voltage rating chart. Adjustment range ±5% minimum except HA series. Line Regulation for a 10% change. Load Regulation ± for a 50% load change. Output Ripple 3 mV of output voltage, peak to peak maximum. All “3-terminal regulator” outputs 3 mV peak to peak maximum. Transient Response <50 microseconds for 50% load change. Short Circuit Protection Automatic current limit/foldback. Overvoltage Protection Built-in on all 5 V models, set at V. Other models use optional overvoltage protection. • Medical leakage current does not exceed 10 µA • MTBF 200,000+ hours per Mil Handbk 217D most units • All electrolytic caps rated at 105ºC • Transformer insulation meets Class F 155ºC • Exceed FCC and CISPR22, Class B conducted emissions • marked to LVD Remote Sensing Provided on all models open sense lead protection built-in except HA series . Stability for 24 hours after warmup. Temperature Rating 0 to 50°C full rated, derated linearly to 40% at 70°C. Temperature Coefficient ±0.01%/°C maximum. Efficiency 5 V units 45% 12 and 15 V units 55% 20 and 24 V units: Logic Inhibit and Current-Share F & G models. Medical Stock and Vibration Per Mil-Std-810D, Method Category 1, Procedure Per Mil-Std-810D, Method Procedure III. Storage -40 to +85 °C. Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033 800-235-5929 • 805-486-4565 • FAX 805-487-8911 • Commercial/Medical International + Linears Commercial Model Single HA2-1.5-A+ HB2-3-A+ HC2-6-A+ HN2-9-A+ HD2-12-A+ HE2-18-A+* HA5-1.5-OV-A+ HB5-3-OV-A+ HC5-6-OV-A+ HN5-9-OV-A+ HD5-12-OV-A+ HE5-18-OV-A+* F5-25-OV-A+* G5-35-OV-A+* CP197-A+* HA15-0.9-A+ 12 V HB12-1.7-A+ HC12-3.4-A+ HN12-5.1-A+ HD12-6.8-A+ HE12-10-2-A+* F15-15-A+* 12V HA15-0.9-A+ HB15-1.5-A+ HC15-3-A+ HN15-4.5-A+ HD15-6-A+ HE15-9-A+* F15-15-A+* HA24-0.5-A+ HB24-1.2-A+ HC24-2.4-A+ HN24-3.6-A+ HD24-4.8-A+ HE24-7.2-A+* F24-12-A+* HA24-0.5-A+ 28V HB28-1-A+ HC28-2-A+ HN28-3-A+ HD28-4-A+ HE28-6-A+* F24-12-A+* 28V HB48-0.5-A+ HC48-1-A+ HD48-3-A+** HE48-4-A+* F48-6-A+* Medical Model ML5-OV-A MB5-3-OV-A MC5-6-OV-A MD5-12-OV-A ML12-0.5-A MB12-1.7-A MC12-3.4-A MD12-6.8-A ML15-0.4-A MB15-1.5-A MC15-3-A MD15-6-A ML24-0.28-A MB24-1.2-A MC24-2.4-A MD-24-4.8-A MB28-1-A MC28-2-A MD28-4-A Voltage 2V 5V 12 V 12 V 12 V 12 V 12 V 12 V 12 V 12 V 15 V 15 V 15 V 15 V 15 V 15 V 15 V 15 V 24 V 24 V 24 V 24 V 24 V 24 V 24 V 24 V 28 V 28 V 28 V 28 V 28 V 28 V 28 V 48 V 48 V 48 V 48 V 48 V Current |
More datasheets: BC182L_D74Z | BC182L_D27Z | 2255 | ML5-1-OV-A | ML12-0.5-A | MTAA-16W-A | MD5-12-OV-A | ML15-0.4-A | MBB524-A | MLL12-0.25-A |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived MLL15-0.2-A Datasheet file may be downloaded here without warranties.