IAGX-6-21F..00164410

IAGX-6-21F..00164410 Datasheet


IAG/IUG/IEG/CEG/LEG Series

Part Datasheet
IAGX-6-21F..00164410 IAGX-6-21F..00164410 IAGX-6-21F..00164410 (pdf)
Related Parts Information
IEGX11-1-62-1.10-43-V IEGX11-1-62-1.10-43-V IEGX11-1-62-1.10-43-V
IEGX11-1-62-.500-43-V IEGX11-1-62-.500-43-V IEGX11-1-62-.500-43-V
IEGX6-1-61-20.0-03-V IEGX6-1-61-20.0-03-V IEGX6-1-61-20.0-03-V
IEGX6-1-61-15.0-03-V IEGX6-1-61-15.0-03-V IEGX6-1-61-15.0-03-V
IEGX6-1-61-10.0-03-V IEGX6-1-61-10.0-03-V IEGX6-1-61-10.0-03-V
IEGX666-1-52-15.0-03-V IEGX666-1-52-15.0-03-V IEGX666-1-52-15.0-03-V
IEGX6-1-52-50.0-A-03-V IEGX6-1-52-50.0-A-03-V IEGX6-1-52-50.0-A-03-V
IUGX666-3680-1 IUGX666-3680-1 IUGX666-3680-1
IUGHX11-28075-4 IUGHX11-28075-4 IUGHX11-28075-4
IEGX6-1-61-30.0-A-46-V IEGX6-1-61-30.0-A-46-V IEGX6-1-61-30.0-A-46-V
IEGX1-1-51-10.0-03-V IEGX1-1-51-10.0-03-V IEGX1-1-51-10.0-03-V
IUGHX114-40266-2 IUGHX114-40266-2 IUGHX114-40266-2
IEGX6666-1-62-20.0-03-V IEGX6666-1-62-20.0-03-V IEGX6666-1-62-20.0-03-V
IAGX-6-21..00199850 IAGX-6-21..00199850 IAGX-6-21..00199850
IEGX6-1-62-30.0-A-02-V IEGX6-1-62-30.0-A-02-V IEGX6-1-62-30.0-A-02-V
IEGX66-1-62-20.0-A-02-V IEGX66-1-62-20.0-A-02-V IEGX66-1-62-20.0-A-02-V
IUGX-6-11-M..00222666 IUGX-6-11-M..00222666 IUGX-6-11-M..00222666
IUGX-6-11-M..S00209937 IUGX-6-11-M..S00209937 IUGX-6-11-M..S00209937
IUGX-6-21-M..00209856 IUGX-6-21-M..00209856 IUGX-6-21-M..00209856
IEGX1-1-52-15.0-A-23-V IEGX1-1-52-15.0-A-23-V IEGX1-1-52-15.0-A-23-V
IEGX66-1-63F-15.0-02-V IEGX66-1-63F-15.0-02-V IEGX66-1-63F-15.0-02-V
IUGX-6-11-M..S00283258 IUGX-6-11-M..S00283258 IUGX-6-11-M..S00283258
IAGX66-1-61-2.60-01 IAGX66-1-61-2.60-01 IAGX66-1-61-2.60-01
IEGX66-1-62-50.0-A-22-V IEGX66-1-62-50.0-A-22-V IEGX66-1-62-50.0-A-22-V
IEGX66-1-63-13.0-02-V IEGX66-1-63-13.0-02-V IEGX66-1-63-13.0-02-V
IEGX66-1-63F-6.50-02-V IEGX66-1-63F-6.50-02-V IEGX66-1-63F-6.50-02-V
IEGX666-1-62-20.0-A-22-V IEGX666-1-62-20.0-A-22-V IEGX666-1-62-20.0-A-22-V
IEGX666-1-62-30.0-A-22-V IEGX666-1-62-30.0-A-22-V IEGX666-1-62-30.0-A-22-V
IEGX666-1-62-50.0-A-22-V IEGX666-1-62-50.0-A-22-V IEGX666-1-62-50.0-A-22-V
IEGX666-1-69-20.0-03-V IEGX666-1-69-20.0-03-V IEGX666-1-69-20.0-03-V
IEGX666-1-69-20.0-A-92-V IEGX666-1-69-20.0-A-92-V IEGX666-1-69-20.0-A-92-V
IEGX66-1-63-18.0-02-V IEGX66-1-63-18.0-02-V IEGX66-1-63-18.0-02-V
IUGX11-1-61-20.0-C-21 IUGX11-1-61-20.0-C-21 IUGX11-1-61-20.0-C-21
IAGX6-1-52-20.0-A-43 IAGX6-1-52-20.0-A-43 IAGX6-1-52-20.0-A-43
IEGX66-1-62-20.0-03-V IEGX66-1-62-20.0-03-V IEGX66-1-62-20.0-03-V
IEGX6-1-52-15.0-03-V IEGX6-1-52-15.0-03-V IEGX6-1-52-15.0-03-V
IEGX66-1-52-15.0-03-V IEGX66-1-52-15.0-03-V IEGX66-1-52-15.0-03-V
IEGX666-1-61-30.0-02-V IEGX666-1-61-30.0-02-V IEGX666-1-61-30.0-02-V
IEGX6666-1-62-30.0-03-V IEGX6666-1-62-30.0-03-V IEGX6666-1-62-30.0-03-V
IUGHX11-1-61-18.0-C-01 IUGHX11-1-61-18.0-C-01 IUGHX11-1-61-18.0-C-01
IUGHX11-40263-1 IUGHX11-40263-1 IUGHX11-40263-1
IUGHX11-40263-2 IUGHX11-40263-2 IUGHX11-40263-2
IUGHX14-40266-3 IUGHX14-40266-3 IUGHX14-40266-3
IUGX11-1-61-17.0-01 IUGX11-1-61-17.0-01 IUGX11-1-61-17.0-01
IAGX6-1-51-5.00-91 IAGX6-1-51-5.00-91 IAGX6-1-51-5.00-91
IEGX11-1-62F-10.0-03-V IEGX11-1-62F-10.0-03-V IEGX11-1-62F-10.0-03-V
IAGX1-1-61-.100-01 IAGX1-1-61-.100-01 IAGX1-1-61-.100-01
IAGX111-1-41-5.00-91 IAGX111-1-41-5.00-91 IAGX111-1-41-5.00-91
IAGX6-0-SW-30.0-01 IAGX6-0-SW-30.0-01 IAGX6-0-SW-30.0-01
IAGX66-1-61-10.0-01 IAGX66-1-61-10.0-01 IAGX66-1-61-10.0-01
IAGX66-1-61-15.0-01 IAGX66-1-61-15.0-01 IAGX66-1-61-15.0-01
IAGX666-1-42-5.00-91 IAGX666-1-42-5.00-91 IAGX666-1-42-5.00-91
IAGX666-1-61-15.0-20 IAGX666-1-61-15.0-20 IAGX666-1-61-15.0-20
IEGX1-1-62F-14.0-02-V IEGX1-1-62F-14.0-02-V IEGX1-1-62F-14.0-02-V
IEGX11-1-61-17.0-03-V IEGX11-1-61-17.0-03-V IEGX11-1-61-17.0-03-V
IEGX66-1-62-30.0-A-22-V IEGX66-1-62-30.0-A-22-V IEGX66-1-62-30.0-A-22-V
IEGX11-1-61-8.00-03-V IEGX11-1-61-8.00-03-V IEGX11-1-61-8.00-03-V
IEGX66-1-62-25.0-22-V IEGX66-1-62-25.0-22-V IEGX66-1-62-25.0-22-V
IEGX11-1-62F-10.0-42-V IEGX11-1-62F-10.0-42-V IEGX11-1-62F-10.0-42-V
IEGX11-1-62F-10.0-A-42-V IEGX11-1-62F-10.0-A-42-V IEGX11-1-62F-10.0-A-42-V
IEGX111-1-61-20.0-02-V IEGX111-1-61-20.0-02-V IEGX111-1-61-20.0-02-V
IEGX111-1-62-30.0-C-03-V IEGX111-1-62-30.0-C-03-V IEGX111-1-62-30.0-C-03-V
IEGX6-1-59-40.0-02-V IEGX6-1-59-40.0-02-V IEGX6-1-59-40.0-02-V
IEGX6-1-61-15.0-06-V IEGX6-1-61-15.0-06-V IEGX6-1-61-15.0-06-V
IEGX66-1-61-25.0-05-V IEGX66-1-61-25.0-05-V IEGX66-1-61-25.0-05-V
IEGX66-1-61-30.0-03-V IEGX66-1-61-30.0-03-V IEGX66-1-61-30.0-03-V
IEGX66-1-61-7.50-03-V IEGX66-1-61-7.50-03-V IEGX66-1-61-7.50-03-V
IAGX6-1-52-20.0-A-23 IAGX6-1-52-20.0-A-23 IAGX6-1-52-20.0-A-23
IEGX11-1-61-20.0-03-V IEGX11-1-61-20.0-03-V IEGX11-1-61-20.0-03-V
IUGX666-1-41-10.0-01 IUGX666-1-41-10.0-01 IUGX666-1-41-10.0-01
IAGX11-1-62-30.0-91 IAGX11-1-62-30.0-91 IAGX11-1-62-30.0-91
214PC..MCR 214PC..MCR 214PC..MCR
IUGX66-1-62-40.0-01 IUGX66-1-62-40.0-01 IUGX66-1-62-40.0-01
IUGX6666-1-62-50.0-01 IUGX6666-1-62-50.0-01 IUGX6666-1-62-50.0-01
IAGX006-40271-1 IAGX006-40271-1 IAGX006-40271-1
IUGX666-1-61-20.0-01 IUGX666-1-61-20.0-01 IUGX666-1-61-20.0-01
IUGX666-1-41-20.0-01 IUGX666-1-41-20.0-01 IUGX666-1-41-20.0-01
IUGX1-1-66-30.0-01 IUGX1-1-66-30.0-01 IUGX1-1-66-30.0-01
IUGX11-1-62F-15.0-A-21 IUGX11-1-62F-15.0-A-21 IUGX11-1-62F-15.0-A-21
IUGX666-1-41-5.00-01 IUGX666-1-41-5.00-01 IUGX666-1-41-5.00-01
IUGX666-1REC5-62-40.0-B-91 IUGX666-1REC5-62-40.0-B-91 IUGX666-1REC5-62-40.0-B-91
IUGX666-1-63F-30.0-01 IUGX666-1-63F-30.0-01 IUGX666-1-63F-30.0-01
IUGX6-1-65-25.0-21 IUGX6-1-65-25.0-21 IUGX6-1-65-25.0-21
IUGX1-0-91 IUGX1-0-91 IUGX1-0-91
IUGX119-24485-1 IUGX119-24485-1 IUGX119-24485-1
IUGX66-1-66-16.0-AM-01-U IUGX66-1-66-16.0-AM-01-U IUGX66-1-66-16.0-AM-01-U
IUGX666-1-61-30.0-01 IUGX666-1-61-30.0-01 IUGX666-1-61-30.0-01
IUGX66-1-66-20.0-01 IUGX66-1-66-20.0-01 IUGX66-1-66-20.0-01
IUGX666-1-61-25.0-01 IUGX666-1-61-25.0-01 IUGX666-1-61-25.0-01
IUGX666-1-42-10.0-21 IUGX666-1-42-10.0-21 IUGX666-1-42-10.0-21
IUGX66-1-66-23.0-01 IUGX66-1-66-23.0-01 IUGX66-1-66-23.0-01
IUGX66-1-66-26.0-A-01-U IUGX66-1-66-26.0-A-01-U IUGX66-1-66-26.0-A-01-U
IUGX662-21769-1 IUGX662-21769-1 IUGX662-21769-1
IUGX662-7206-3 IUGX662-7206-3 IUGX662-7206-3
IUGX666-1-41-15.0-01 IUGX666-1-41-15.0-01 IUGX666-1-41-15.0-01
IUGX666-1-43-2.50-21 IUGX666-1-43-2.50-21 IUGX666-1-43-2.50-21
IUGX666-1-49-30.0-B-21 IUGX666-1-49-30.0-B-21 IUGX666-1-49-30.0-B-21
IAGX11-2658-2 IAGX11-2658-2 IAGX11-2658-2
IAGX66-2657-3 IAGX66-2657-3 IAGX66-2657-3
IUGX111-9891-3 IUGX111-9891-3 IUGX111-9891-3
IEGX11-25021-2-V IEGX11-25021-2-V IEGX11-25021-2-V
IEGX111-27650-2 IEGX111-27650-2 IEGX111-27650-2
IEGX112-28529-2 IEGX112-28529-2 IEGX112-28529-2
IUGX66-3680-2 IUGX66-3680-2 IUGX66-3680-2
IEGX11-25208-1-V IEGX11-25208-1-V IEGX11-25208-1-V
IEGX62-27415-1-V IEGX62-27415-1-V IEGX62-27415-1-V
IEGX12-28529-1 IEGX12-28529-1 IEGX12-28529-1
IEGX12-28537-1-V IEGX12-28537-1-V IEGX12-28537-1-V
IEGX21-24658-1-V IEGX21-24658-1-V IEGX21-24658-1-V
IEGX2-29420-1-V IEGX2-29420-1-V IEGX2-29420-1-V
IUGX112-4810-2 IUGX112-4810-2 IUGX112-4810-2
IUGX112-28529-4 IUGX112-28529-4 IUGX112-28529-4
IEGX26-29046-1-V IEGX26-29046-1-V IEGX26-29046-1-V
IEGX11-27168-1-V IEGX11-27168-1-V IEGX11-27168-1-V
IUGHX26-29909-1 IUGHX26-29909-1 IUGHX26-29909-1
IEGX111-28530-1-V IEGX111-28530-1-V IEGX111-28530-1-V
IEGX626-27702-2-V IEGX626-27702-2-V IEGX626-27702-2-V
IEGX66-28271-5-V IEGX66-28271-5-V IEGX66-28271-5-V
IEGX66-35837-26-UC IEGX66-35837-26-UC IEGX66-35837-26-UC
IEGX666-1REC4-27596-3-V IEGX666-1REC4-27596-3-V IEGX666-1REC4-27596-3-V
PDF Datasheet Preview
IAG/IUG/IEG/CEG/LEG Series

Magnetic Circuit Protectors

Introduction Poles

Handles Configurations Operating Characteristics

Delay Curves Specifications Decision Tables
• 99
• 100
• 103
• 108
• 110
• 111
• 115
• 117

IAG/IUG/IEG/CEG/LEG Series

Hydraulic Magnetic Circuit Protectors

INTRODUCTION

The Airpax IAG/IUG/IEG/CEG/LEG magnetic circuit protectors provide low-cost power switching, reliable circuit protection and accurate circuit control for equipment in the international marketplace.

IEG models meet IEC spacing requirements which is mandatory for equipment that must comply with IEC specifications 601 and 950 and VDE specifications 0804 and In addition, they are UL Recognized as supplementary protectors per UL STD. 1077, CSA Certified as supplementary protectors per CSA 235, VDE Approved to VDE 0642 EN60934 , CCC Approved and CE Compliant. IAG models are for those applications where the unit’s inherent attributes are desired, but compliance with the various standards is not required.

Designed using the latest in sensitive hydraulic magnetic technology, the IAG/IUG/IEG/CEG/LEG line adapts itself to many applications and environments. They’re ideal for data processing and business machines, medical instrumentation, broadcast
equipment, vending and amusement machines, military applications and wherever precision operation is required. Temperature differences which affect fuses and other thermal devices are not a concern.

One important feature of this protector line is a “trip free” action, which means the circuit will trip in the presence of an overload even though the handle is held in the ON position. The delay mechanism senses the fault and the contacts open.

The IAG/IUG/IEG/CEG/LEG is available in a wide variety of configurations including series, series with auxiliary switch, shunt and relay with a choice of delays and ratings in either DC, 50/60Hz or 400Hz versions. Handles come in seven different colors and international markings are standard. Single or multipole versions are available, with a variety of pole arrangements to meet your specifications. Four pole models require a double toggle handle. Units with a handle per pole come in one through six pole assemblies.
99 IAG Series - Introduction

IAG Series

SINGLE POLE CIRCUIT PROTECTOR

MAX.
2X 6 32 THREAD DEEP M3 ISO THD. OPTIONAL

Note Tolerance unless noted. Dimensions in brackets [ ] are millimeters.

LEG Type Units Require Screw Terminals

Single Pole Mounting Detail

IAG Series - Poles 100

MULTI-POLE CIRCUIT PROTECTORS IAG/IUG/IEG/CEG/LEG

Two Pole Protectors

An assembly consisting of two single pole units, having their trip mechanisms internally coupled and with a single toggle handle, forms the IEG11 with quick-connect D.I.N.-style terminals. Individual poles may differ in ratings, delays and internal connections. An auxiliary switch may be included in either or both poles, allowing you to mix SELV and hazardous voltages. Rugged screw-type terminals can be provided, in which case the designation would be IEG66. The IEGH offers a toggle handle for each pole. LEG type units are avavailable only in one or two pole configurations.

Three Pole and Four Pole Protectors

The three pole construction consists of three single pole units assembled with an internal mechanical interlock which actuates
all units simultaneously. A single toggle handle operates all three poles for quick and convenient control, or if preferred, a handle per pole is available. The four pole construction consists of four single pole units assembled with an internal mechanical interlock which actuates all units simultaneously. A double toggle handle operates all four poles. The individual poles need not have identical characteristics and any series trip pole may have an auxiliary switch. If screw-type terminals are required, the breaker designation will be IEG666 for a three pole version and IEG6666 for a four pole version.

Protector poles are numbered consecutively when viewed from the terminal side, with the ON position up, starting with Pole #1 on the left side and proceeding to the right.

IAG/IUG/IEG/CEG/LEG

ON 32º
32º OFF

IAG/IUG/IEG/CEG/LEG Multi-Pole Circuit Breakers

Two Pole*

Three Pole*

Four Pole*

MAX.

LEG Type Units Require Screw Terminals

MAX.
The ordering code for IAG/IUG/IEG/CEG/IDG circuit protectors may be determined by following the decision steps in the tables shown here.

The coding given permits a self-assigning part number but with certain limitations. Special applications may require a factory-assigned part number. Typical examples are units with mixed ratings, combinations of styles, or constructions not listed in the third decision table. With these, it is suggested that order entry be by description and/or drawings and a part number will be established. Additionally, it is standard policy to establish a factory-assigned part number whenever a descriptive drawing exists to provide cross reference, traceability and manufacturing control.

When specifying a circuit protector for AC motor start or high inrush applications, the peak amplitude and surge duration should be specified for factory assistance in rating selection.

For example, the following is the code for a single pole, IEG quick-connect type terminal, series unit with auxiliary switch, designed for operation in a 50/60Hz circuit. It has a short time delay, a rating of 20 amperes, a black marked handle and is VDE approved.
To determine the ordering number for your particular IAG/IUG/IEG/CEG unit, simply follow the steps shown. You may use this number to place an order or as a reference for further questions you may have.
is recommended that power leads be soldered to circuit protectors having push-on type terminals for current trip ratings above 20 amperes.
“A” metric thread mounting is specified in the sixth decision in combination with screw terminal option in the second decision, metric screw terminals are supplied.

IEGH, IEGS, IEGHS, IEGX and IEGZX circuit protectors are designed to meet 8mm creepage and clearance requirements for installation Category III, Pollution Degree 3, Case A as measured in IEC Intended for use in equipment designed to comply with IEC 601 and 950 and VDE 0804 and
1 First Decision

Select Type and Terminal

Type

IAG IUG* IEG** CUG+ CEG++

IAGH IUGH* IEGH** CUGH+ CEGH++

IDG***

One toggle handle per unit

One toggle handle per pole One toggle handle per unit, marine ignition protection

IDGH***

One toggle handle per pole marine ignition protection

IMG** One toggle handle per unit CMG++ mid-trip indication

IMGH** One toggle handle per pole CMGH++ mid-trip indication
*UL Recognized, CSA Certi ed **UL Recognized, CSA Certi ed, VDE Approved *** UL Recognized UL1500 + UL489A Listed CSA Certi ed ++ UL489AListed CSA Certi ed VDE Approved

Handle and Mounting Options

Standard toggle/mounting, no designation required S Toggle w/ snap-in mounting X Rocker w/ standard mounting* ZX Rocker w/ integral mounting* BX Rocker w/ integral mounting N Sealed toggle w/bushing mounting**

Note Add "F" for at screw terminals * Not available on mid-trip units ** Available only on IAG, IUG units
2 Second Decision Poles and Terminals

Push-on Terminals

Screw Terminals

Single pole

Two pole

Three pole
1111
6666

Four pole
*Not available in toggle seal handle type.

Example IEG 1 - 1REC4 - 61 -
- 01 - V
12 3 4 567
3 Third Decision Internal Con guration

Switch only

Series
-1REC4 Series w/ auxiliary switch * quick connect
-1REC5 Series w/ auxiliary switch * quick connect
-1REG4 Series w/ auxiliary switch gold contacts * quick connect
-1RS4

Series w/ alarm switch, electrical trip, Q.C. terminals
The ordering code for LEG circuit breakers may be determined by following the decision steps in the tables shown here.

The coding given permits a self-assigning part number but with certain limitations. Special applications may require a factory-assigned part number. Typical examples are units with mixed ratings, combinations of styles, or constructions not listed in the third decision table. With these, it is suggested that order entry be by description and/or drawings and a part number will be established. Additionally, it is standard policy to establish a factoryassigned part number whenever a descriptive drawing exists to provide cross reference, traceability and manufacturing control.

When specifying a circuit breaker for AC motor start or high inrush applications, the peak amplitude and surge duration should be specified for factory assistance in rating selection.

For example, the following is the code for a single pole, LEG screw type terminal, series unit with auxiliary switch, designed for operation in a 50/60Hz circuit. It has a short time delay, a rating of 20 amperes, a black marked handle and is VDE approved.
To determine the ordering number for your particular LEG unit, simply follow the steps shown. You may use this number to place an order or as a reference for further questions you may have.

Notes “A” metric thread mounting is specified in the sixth
decision in combination with screw terminal option in the second decision, metric screw terminals are supplied.

EG, LEGH, LEGS, LEGHS, LEGZX and LEGBX circuit breakers are designed to meet 8mm creepage and clearance requirements for installation Category III, Pollution Degree 3, Case A as measured in IEC Intended for use in equipment designed to comply with IEC 601 and 950 and VDE 0804 and
1 First Decision Select Type and Terminal

Type Description

LEG LMG

One toggle handle per unit

One toggle handle per unit mid-trip indication

LEGH One toggle handle per pole

LMGH

One toggle handle per pole mid-trip indication

Note All types are UL489 listed, CUL

Handle and Mounting Options

Standard toggle/mounting, no designation required S Toggle w/ snap-in mounting ZX Rocker w/ integral mounting* BX Rocker w/ integral mounting

Note Add "F" for screw terminals * Not available on mid-trip units
2 Second Decision

Poles and Terminals

Push-on Screw Terminals

Single pole

Two pole
*Not available in toggle seal handle type.

Example:

LEG 6 - 1REC4 - 61 -
- 01 - V
12 3 4 567
3 Third Decision Internal

Series
-1REC4 Series w/ auxiliary switch * quick connect
-1REC5 Series w/ auxiliary switch * quick connect
-1REG4

Series w/ auxiliary switch* gold contacts quick connect
-1RS4

Series w/ alarm switch*, electrical trip, Q.C. terminals
-1RLS4

Series w/ alarm switch*, electrical trip, mid-trip only, Q.C. terminals

Shunt
* Only one auxiliary switch is normally supplied on two pole units. Switch is located in the right-hand pole viewed from terminal end unless otherwise
4 Fourth Decision Frequency and Delay
-61 50/60Hz short delay
-62 50/60Hz long delay
More datasheets: IEGX6-1-61-15.0-03-V | IEGX6-1-61-10.0-03-V | IEGX666-1-52-15.0-03-V | IEGX6-1-52-50.0-A-03-V | IUGX666-3680-1 | IUGHX11-28075-4 | IEGX6-1-61-30.0-A-46-V | IEGX1-1-51-10.0-03-V | IUGHX114-40266-2 | IEGX6666-1-62-20.0-03-V


Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived IAGX-6-21F..00164410 Datasheet file may be downloaded here without warranties.