ATR20-A-63S-WB2-B-20.0A-2

ATR20-A-63S-WB2-B-20.0A-2 Datasheet


ATR20 Series Thermal Circuit Protector for Equipment

Part Datasheet
ATR20-A-63S-WB2-B-20.0A-2 ATR20-A-63S-WB2-B-20.0A-2 ATR20-A-63S-WB2-B-20.0A-2 (pdf)
Related Parts Information
ATR20-A-63S-WB2-B-15.0A-2 ATR20-A-63S-WB2-B-15.0A-2 ATR20-A-63S-WB2-B-15.0A-2
ATR20-A-63S-WB2-B-10.0A-2 ATR20-A-63S-WB2-B-10.0A-2 ATR20-A-63S-WB2-B-10.0A-2
ATR20-A-63S-WB2-B-12.0A-2 ATR20-A-63S-WB2-B-12.0A-2 ATR20-A-63S-WB2-B-12.0A-2
ATR20-W-63S-B1-N-8.0A-0 ATR20-W-63S-B1-N-8.0A-0 ATR20-W-63S-B1-N-8.0A-0
ATR20-W-63S-B1-N-5.0A-0 ATR20-W-63S-B1-N-5.0A-0 ATR20-W-63S-B1-N-5.0A-0
ATR20-A-63S-WB2-B-8.0A-2 ATR20-A-63S-WB2-B-8.0A-2 ATR20-A-63S-WB2-B-8.0A-2
ATR20-A-63S-WB2-B-5.0A-2 ATR20-A-63S-WB2-B-5.0A-2 ATR20-A-63S-WB2-B-5.0A-2
ATR20-W-63S-B1-N-12.0A-0 ATR20-W-63S-B1-N-12.0A-0 ATR20-W-63S-B1-N-12.0A-0
ATR20-W-63S-B1-N-15.0A-0 ATR20-W-63S-B1-N-15.0A-0 ATR20-W-63S-B1-N-15.0A-0
ATR20-W-63S-B1-N-20.0A-0 ATR20-W-63S-B1-N-20.0A-0 ATR20-W-63S-B1-N-20.0A-0
ATR20-W-63S-B1-N-10.0A-0 ATR20-W-63S-B1-N-10.0A-0 ATR20-W-63S-B1-N-10.0A-0
PDF Datasheet Preview
ATR20 Series Thermal Circuit Protector for Equipment
• RoHS compliant, single pole, thermal current overload protector
• Reliable, trip-free operation on current overloads
• Warranty 24-months from date of manufacture
• Protection range and operating voltage to Amps, 240 VAC, 50 VDC to 12 Amps, 240 VAC, 24 VDC VDE

The Airpax ATR20 product family is a single pole, thermally operated overload protector with a snap-acting trip mechanism that provides reliable, trip-free operation on current overloads. The ATR20 series is designed with multiple mounting configurations including central nut and wing clip.

Specifications Standard Current Ratings Voltage Ratings Max Breaking Capacity

Conditional Short Circuit Capacity Inc1 PC1 per EN 60934

Rated Short Circuit Capacity Icn Ref. EN 60934

Tripping Current Code TC Insulation Resistance Dielectric Strength

Initial Withstand Voltage Operational Life Overload Rating

Overload Switching Capacity

Max Operating Temperature Application Type

Method of Tripping Type of Actuation Weight

Applicable Approvals

ATR20 Series
3, 4, 5, 6, 7, 8, 10, 12, 15, 16, 20 Amps AC - inductive, DC - resistive 125 / 250 VAC, 50/60 Hz, 50 VDC 8x In for < 6A, 60A max. > 6A
1000A 125 / 250VAC, 50VDC,SC:1kA, C1, 125 / 250VAC, 50VDC Ref. CSA No. 235-04, UL 1077

Min. 6 X Rated Current 6 X In , 250VAC inductive Min. 4 X Rated Current 4 X In , 50VDC resistive

TC2 ref CSA22.2, No. 235-04 Min 100 MΩ 500VDC

KV for 1 min. per EN60934 KV per EN60934 1000 Cycles 2 x In

OL0 240Vac, 50Vdc, ref CSA22.2, No. 235-04 6x In AC Up to 9A, 4x In DC Up to 12A 60A Max. from 10A to 12A 60°C 140°F Ambient

General Industrial ref CSA22.2, No. 235-04 Thermal “TO”, trip-free Reset button, type “R” Approximately 17 grams

UL 1077, CSA No. 235-04, TÜV EN 60934

ADDITIONAL PRODUCTS

TIME / CURRENT CHARACTERISTICS

The standard characteristic is valid for an ambient temperature of 25°C. However, if the device is to be used in an ambient temperature other than 25°C, an allowance must be made when selecting the current rating.

See the charts, graph and example below to help determine the right circuit protector rating for your application.

Ambient temperature correction factor - amp circuit protector

Ambient Temperature °C

Multiplication Factor

Ambient temperature correction factor - 3 amp to 4 amp circuit protector

Ambient Temperature °C

Multiplication Factor

Ambient temperature correction factor - 5 amp to 20 amp circuit protector

Ambient Temperature °C - 20

Multiplication Factor

Example :

Normal Continuous Current = A Ambient Temperature = 40°C Multiplication Factor = from 3rd chart

Recommended Rating x = Select the Nearest Rating = amps nearest

Operating Characteristics :
1000

Trip Time sec
More datasheets: 703P7R-114 | 700PR-002 | PT7M8206B33TA5EX-2017 | PT7M8206B12TA5EX-2017 | PT7M8206B18TA5EX-2017 | ATR20-A-63S-WB2-B-15.0A-2 | ATR20-A-63S-WB2-B-10.0A-2 | ATR20-A-63S-WB2-B-12.0A-2 | ATR20-W-63S-B1-N-8.0A-0 | ATR20-W-63S-B1-N-5.0A-0


Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived ATR20-A-63S-WB2-B-20.0A-2 Datasheet file may be downloaded here without warranties.

Datasheet ID: ATR20-A-63S-WB2-B-20.0A-2 515852