ATR11-D-X-63-WB-6.0A

ATR11-D-X-63-WB-6.0A Datasheet


ATR11 Series Thermal Circuit Protector for Equipment

Part Datasheet
ATR11-D-X-63-WB-6.0A ATR11-D-X-63-WB-6.0A ATR11-D-X-63-WB-6.0A (pdf)
Related Parts Information
ATR11-D-X-63-WB-8.0A ATR11-D-X-63-WB-8.0A ATR11-D-X-63-WB-8.0A
ATR11-D-Y-63-WB-12.0A ATR11-D-Y-63-WB-12.0A ATR11-D-Y-63-WB-12.0A
ATR11-D-X-63-WB-2.0A ATR11-D-X-63-WB-2.0A ATR11-D-X-63-WB-2.0A
ATR11-C-X-63-BB-0.5A ATR11-C-X-63-BB-0.5A ATR11-C-X-63-BB-0.5A
ATR11-C-X-63-BB-1.0A ATR11-C-X-63-BB-1.0A ATR11-C-X-63-BB-1.0A
ATR11-C-X-63-BB-2.0A ATR11-C-X-63-BB-2.0A ATR11-C-X-63-BB-2.0A
ATR11-C-X-63-BB-3.0A ATR11-C-X-63-BB-3.0A ATR11-C-X-63-BB-3.0A
ATR11-C-X-63-BB-4.0A ATR11-C-X-63-BB-4.0A ATR11-C-X-63-BB-4.0A
ATR11-D-X-63-WB-1.0A ATR11-D-X-63-WB-1.0A ATR11-D-X-63-WB-1.0A
ATR11-C-X-63-B-1-N-5. ATR11-C-X-63-B-1-N-5. ATR11-C-X-63-B-1-N-5.
ATR11-D-Y-63-WB-15.0A ATR11-D-Y-63-WB-15.0A ATR11-D-Y-63-WB-15.0A
ATR11-D-Y-63-WB-10.0A ATR11-D-Y-63-WB-10.0A ATR11-D-Y-63-WB-10.0A
ATR11-D-X-63-WB-4.0A ATR11-D-X-63-WB-4.0A ATR11-D-X-63-WB-4.0A
ATR11-D-X-63-WB-0.5A ATR11-D-X-63-WB-0.5A ATR11-D-X-63-WB-0.5A
ATR11-D-X-63-WB-5.0A ATR11-D-X-63-WB-5.0A ATR11-D-X-63-WB-5.0A
ATR11-C-X-63-BB-5.0A ATR11-C-X-63-BB-5.0A ATR11-C-X-63-BB-5.0A
ATR11-C-Y-63-BB-15.0A ATR11-C-Y-63-BB-15.0A ATR11-C-Y-63-BB-15.0A
ATR11-C-Y-63-BB-12.0A ATR11-C-Y-63-BB-12.0A ATR11-C-Y-63-BB-12.0A
ATR11-C-Y-63-BB-10.0A ATR11-C-Y-63-BB-10.0A ATR11-C-Y-63-BB-10.0A
ATR11-C-X-63-BB-8.0A ATR11-C-X-63-BB-8.0A ATR11-C-X-63-BB-8.0A
ATR11-C-X-63-BB-7.0A ATR11-C-X-63-BB-7.0A ATR11-C-X-63-BB-7.0A
ATR11-C-X-63-BB-6.0A ATR11-C-X-63-BB-6.0A ATR11-C-X-63-BB-6.0A
ATR11-D-X-63-WB-3.0A ATR11-D-X-63-WB-3.0A ATR11-D-X-63-WB-3.0A
ATR11-D-X-63-WB-7.0A ATR11-D-X-63-WB-7.0A ATR11-D-X-63-WB-7.0A
PDF Datasheet Preview
ATR11 Series Thermal Circuit Protector for Equipment
• RoHS compliant, single pole, thermal current overload protector
• Reliable, trip-free operation on current overloads
• Warranty 24-months from date of manufacture
• Protection range and operating voltage to Amps, 240 VAC, 50 VDC to 12 Amps, 240 VAC, 24 VDC VDE

The Airpax ATR11 product family is a single pole, thermally operated overload protector with a snap-acting trip mechanism that provides reliable, trip-free operation on current overloads. The ATR11 series is designed with multiple mounting configurations including central nut, wing clip, snap-in, integral and PC board mounting.

Specifications Current Ratings Voltage Ratings

Max Breaking Capacity Conditional Short Circuit Capacity

Tripping Current Code TC Insulation Resistance Dielectric Strength Operational Life Overload Rating

Overload Switching Capacity

Max Operating Temperature Application Type

Method of Tripping Type of Actuation

ATR11 Series
to 16 amps, standard ratings available 240 VAC, 50/60 Hz, 50 VDC, 24 VDC VDE
8x In for < 6A, 60A max. > 6A 1KA, PC1, 240Vac 24Vdc
ref EN60934, SC 1KA, C1 240Vac 50Vdc ref CSA22.2 No. UL-1077 TC2 ref CSA22.2, No. 234-04 Min 100 MΩ 500VDC 1,500 VAC for 1 min. 1000 Cycles 2 x In

OL0 240Vac, 50Vdc, ref CSA22.2, No. 235-04 6x In AC Up to 9A, 4x In DC Up to 12A 60A Max. from 10A to 12A 60°C 140°F Ambient

General Industrial ref CSA22.2, No. 235-04 Thermal “TO”, trip-free Reset type “R”

ADDITIONAL PRODUCTS

SHUNT TERMINAL Option N Available on units of up to 6 amps equipped with a heater winding, an optional additional terminal can be provided as a parallel circuit to the main current-sensing circuit. The shunt circuit between terminals 1 and 3 may be used for any signal that may be required in addition to the main circuit. However, since the circuit makes use of the bimetal strip as a current-carrying path, the trip time of the circuit protector may be slightly influenced.

TIME / CURRENT CHARACTERISTICS The standard characteristic is valid for an ambient temperature of 23°C. However, if the device is to be used in an ambient temperature other than 23°C, an allowance must be made when selecting the current rating. See the chart, graph and example below to help determine the right circuit protector rating for your application.

Ambient temperature correction factor

Ambient Temperature °C
- 20 - 5

Multiplication Factor

Example :

Normal Continuous Current = A Ambient Temperature = 40°C Multiplication Factor = from graph

Recommended Rating x = Select the Nearest Rating = 2 amps

Operating Characteristics :
min 60 30 20 10 5
1 S 50
20 10 5

Trip-Time

Multiple of Current Rating

Rated Current
6A ATemmbpieenrat ture 23°C

ATR11 Series

MOUNTING OPTIONS, inches [mm]

Central Mounting C

Printing / Label

Maximum Torque 4 inch-pounds
9 M10X1

R ATR11.....
More datasheets: ATR11-D-X-63-WB-2.0A | ATR11-C-X-63-BB-0.5A | ATR11-C-X-63-BB-1.0A | ATR11-C-X-63-BB-2.0A | ATR11-C-X-63-BB-3.0A | ATR11-C-X-63-BB-4.0A | ATR11-D-X-63-WB-1.0A | ATR11-C-X-63-B-1-N-5. | ATR11-D-Y-63-WB-15.0A | ATR11-D-Y-63-WB-10.0A


Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived ATR11-D-X-63-WB-6.0A Datasheet file may be downloaded here without warranties.

Datasheet ID: ATR11-D-X-63-WB-6.0A 515851