L-22PL012D-C F0411A 12VDC Continuous
Part | Datasheet |
---|---|
![]() |
F0411A (pdf) |
Related Parts | Information |
---|---|
![]() |
F0413A |
![]() |
F0412A |
![]() |
F0414A |
PDF Datasheet Preview |
---|
2110 Queensway Searcy, AR 72143 Phone 501-268-6877 Website: Model L-22 DC Solenoid Open Frame, Pull Type Pontiac Coil - Arkansas is an ISO 9001:2000 Certified Company *Resistance values are ± 10% at 25°C Model Code Part No. Voltage Duty Cycle Power W Resistance Current A L-22PL012D-C F0411A 12VDC Continuous L-22PL012D-I F0412A 12VDC Intermittent L-22PL024D-C F0413A 24VDC Continuous L-22PL024D-I F0414A 24VDC Intermittent Definition of Duty Cycles: Continuous = indefinite activation Intermittent = 1 minute ON and 3 minutes OFF Pulse = 100 msec. ON and 900 msec. OFF Special order options 6 to 48 Volts DC or AC push-type configuration. Consult factory for other modifications. Stroke in. Sealed 1/16 Cont. Duty force 41 oz. 13 oz. 5 oz. 2 oz. 1 oz. Int. Duty force 46 oz. 22 oz. 10 oz. 3 oz. 2 oz. 1 oz. Typical force values when operated at 100% rated voltage at 25°C. Derating required for lower voltage and higher temperature. Solenoid shown energized, with plunger seated Insulation Materials UL Construction, Class B 130°C Copper magnet wire insulation rated 155°C class F Voltage Breakdown Strength 1500 VAC RMS Life Expectancy 10 million operations |
More datasheets: 208284008000030 | 208284014000030 | 108284024003030 | 108284014000040 | 108284014000030 | 108284014001040 | 108284020000040 | 108284024000030 | 108284016000030 | F0413A |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived F0411A Datasheet file may be downloaded here without warranties.