FDDS10H04A_F085A

FDDS10H04A_F085A Datasheet


FDDS10H04A_F085A Smart High Side Switch

Part Datasheet
FDDS10H04A_F085A FDDS10H04A_F085A FDDS10H04A_F085A (pdf)
PDF Datasheet Preview
FDDS10H04A_F085A Smart High Side Switch

April 2012

FDDS10H04A_F085A

Smart High Side Switch
• Short circuit protection with latch
• Current limitation
• Overlaod protection
• Thermal shutdown with restart.
• Overvoltage protection including load dump
• Loss of ground protection
• Loss of supply protection with external diode for charged
inductive load
• Very low standby current
• Fast demagnetization of inductive loads
• ESD protection
• Optimized static electromagnetic compatibility
• Diagnostic function - Proportional load current sense with
defined fault signal in case of overload operation, overtemperature shutdown and/or short circuit shutdown
• Qualified to AEC
• Power switch with current sense diagnostic feedback for DC ground loads
• All types of resistive, inductive, and capacitive loads
• Replace electromechanical relays, fuses and discrete circuits

N channel power FET with charge pump, current controlled input and diagnostic feedbcak with load current sense, integrated in smart Trench chip on chip technology. Provides embedded protective functions.

TO252-5L
Ordering Information

Part Number FDDS10H04A_F085A

Package

TO252-5L

Operating Temperature
-40 C - 150 C

Eco Status Packing Method

Tape & Reel

For Fairchild’s definition of “green” Eco Status, please visit:
2011 Fairchild Semiconductor Corporation

FDDS10H04A_F085A Smart High Side Switch

Block Diagrams

Voltage Source

Charge Current

Gate

Pump

Limit Protection

High-side Driver

Input / Output 2 IN ESD & OVP

Protection

UVLO &

Control Logic

SCIS

Temp. Sense

Current Sense

Overload Detection

Output Voltage Detection

OUT 1

Pin Definitions

Pin Number
1 2 3 4

Pin Name

OUT IN Vbb IS

Pin Function Description

Output to loads Pin1and 5 must be externally shorted

Input activates the power switch if shorted to ground

Supply voltage Pin3 and TAB are internally shorted

Sense output Diagnostic feedback Provides at normal operation a sense
current proportion to the load current in case of overload, over tempera-
ture and/or short circuit a defined current is provided

Output to loads Pin1 and 5 must be externally shorted
More datasheets: 5223 | 5311 | 5113 | 7223 | 7123 | 7211 | 7212 | 7222 | 7221 | 7213


Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived FDDS10H04A_F085A Datasheet file may be downloaded here without warranties.

Datasheet ID: FDDS10H04A_F085A 514150