0662
Part | Datasheet |
---|---|
![]() |
066202.5ZRLL (pdf) |
Related Parts | Information |
---|---|
![]() |
0662.200HXSL |
![]() |
0662.080HXLL |
![]() |
0662.125HXSL |
![]() |
0662.160ZRLL |
![]() |
0662.160HXSL |
![]() |
0662.160HXLL |
![]() |
0662.125ZRLL |
![]() |
0662.200HXLL |
![]() |
0662.125HXLL |
![]() |
0662.100ZRLL |
![]() |
0662.100HXSL |
![]() |
0662.100HXLL |
![]() |
0662.080HXSL |
![]() |
0662.200ZRLL |
![]() |
0662.500ZRLL |
![]() |
0662.080ZRLL |
![]() |
0662.400HXSL |
![]() |
0662.630ZRLL |
![]() |
0662.630HXSL |
![]() |
0662.630HXLL |
![]() |
06623.15HXLL |
![]() |
0662.500HXSL |
![]() |
0662.500HXLL |
![]() |
0662.400ZRLL |
![]() |
0662.250HXLL |
![]() |
0662.400HXLL |
![]() |
0662.315ZRLL |
![]() |
0662.315HXSL |
![]() |
0662.315HXLL |
![]() |
0662.250ZRLL |
![]() |
0662.250HXSL |
![]() |
0662.063ZRLL |
![]() |
0662004.HXLL |
![]() |
066201.6HXSL |
![]() |
066201.6HXLL |
![]() |
0662005.ZRLL |
![]() |
0662005.HXSL |
![]() |
0662005.HXLL |
![]() |
06623.15ZRLL |
![]() |
0662004.HXSL |
![]() |
066202.5HXSL |
![]() |
0662002.ZRLL |
![]() |
0662002.HXSL |
![]() |
0662002.HXLL |
![]() |
0662001.ZRLL |
![]() |
0662001.HXSL |
![]() |
0662001.HXLL |
![]() |
0662004.ZRLL |
![]() |
06623.15HXSL |
![]() |
0662.063HXLL |
![]() |
0662.050ZRLL |
![]() |
0662.050HXSL |
![]() |
0662.050HXLL |
![]() |
0662.040ZRLL |
![]() |
0662.040HXSL |
![]() |
066201.6ZRLL |
![]() |
0662.800HXLL |
![]() |
066202.5HXLL |
![]() |
0662.800HXSL |
![]() |
06621.25ZRLL |
![]() |
06621.25HXSL |
![]() |
06621.25HXLL |
![]() |
0662.063HXSL |
![]() |
0662.040HXLL |
![]() |
0662.800ZRLL |
PDF Datasheet Preview |
---|
Axial Lead and Cartridge Fuses Subminiature LT-5 Fast-Acting Fuse 662 Series ELECTRICAL CHARACTERISTICS: % of Ampere Rating 150% Time 1 hour, Minimum 210% 275% 30 minutes, Maximum sec Min. 3 sec Max 400% sec Min. sec Max 1000% sec Maximum AGENCY APPROVALS IEC 60127-3/1 VDE and Semko approved 50 mA through A. Recognized under the Components Program Underwriters Laboratories and CSA accepted 40mA through 5A. INTERRUPTING RATINGS 35A or 10X rated current whichever is greater. ENVIRONMENTAL SPECIFICATIONS Operating Temperature to Case Resistance Min 100 Mohms, according to EIA/IS-722, Vibration 20gn, 20 min, 10Hz to 2,000Hz, 12 cycles according to EIA/IS-722, Frequency range 10-2000Hz, cross-over frequency 60 Hz according to IEC 60068-2-6, test Fc Mechanical Shock 50g, half sine wave, 11ms, 3 times each direction according to IEC Resistance to Cleaning Solvents Clean according to EIA/IS-722, Resistance to Soldering Heat 10 sec. At to IEC 60068-2-20, test Tb Terminal Strength Tensile load min. 9N, according to EIA/IS-722, PHYSICAL SPECIFICATIONS Materials Temperature Resistant Body, UL 94V-0 Sn Coated Copper Wire Terminals. Solderability IEC 60068-2-20, test Ta Soldering Parameters Wave Solder 2 seconds maximum. PACKAGING Please refer to the following suffixes when ordering • 100 Piece Bulk Short Leads use suffix HXSL; Long Leads use suffix HXLL • 750 Piece Tape and Reel per IEC 286-2: Long Leads only use suffix ZRLL • 1000 Piece Ammo Pack use suffix MALL PATENTED ORDERING INFORMATION: Catalog Number 0662 Ampere Rating Voltage Rating Nominal Resistance Cold mOhms 7500 4483 3866 2545 2010 1346 2960 2256 1460 1209 180 128 96 78 64 45 37 29 24 17 13 10 Nominal Melting I2t A2 Sec Refer to page 342 for LT-5TM holder information. AXIAL LEAD AND CARTRIDGE FUSES Axial Lead and Cartridge Fuses Subminiature LT-5 Fast-Acting Fuse 662 Series Average Time Current Curves 40mA 50mA 63mA 80mA 100mA 125mA 160mA 200mA 250mA 315mA 400mA 500mA 630mA 800mA 1A 1.25A 1.6A 2A 2.5A 3.15A 4A 5A 1000 TIME IN SECONDS CURRENT IN AMPERES |
More datasheets: 0662.050HXLL | 0662.040ZRLL | 0662.040HXSL | 066201.6ZRLL | 0662.800HXLL | 066202.5HXLL | 0662.800HXSL | 06621.25ZRLL | 06621.25HXSL | 06621.25HXLL |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived 066202.5ZRLL Datasheet file may be downloaded here without warranties.