Part | Datasheet |
---|---|
![]() |
0473004.YRT3 (pdf) |
Related Parts | Information |
---|---|
![]() |
0473.375YRT3L |
![]() |
047302.5YRT3L |
![]() |
04732.25YRT3L |
![]() |
0473002.YRT3L |
![]() |
0473.500YRT3L |
![]() |
0473.750YRT3L |
![]() |
047303.5YRT3L |
![]() |
047301.5YRT3L |
![]() |
047301.5YRT1 |
![]() |
047303.5YRT1 |
![]() |
0473003.YRT1 |
![]() |
0473002.YRT1 |
![]() |
047302.5YRT1 |
![]() |
0473001.YRT1 |
![]() |
0473.750YRT1 |
![]() |
0473005.YRT1 |
![]() |
0473.375MRT1 |
![]() |
0473.500YRT1 |
![]() |
0473.750MRT3 |
![]() |
0473002.MRT3 |
![]() |
0473001.MRT3 |
![]() |
0473007.MRT3 |
![]() |
047301.5MRT3 |
![]() |
047302.5MRT3 |
![]() |
047303.5MRT3 |
![]() |
0473.500MRT3 |
![]() |
0473007.YRT1 |
![]() |
0473005.MRT3 |
![]() |
0473003.MRT3 |
![]() |
0473004.MRT3 |
![]() |
04732.25MRT3 |
![]() |
04732.25MRT1 |
![]() |
0473.375MRT3 |
![]() |
047303.5YRT3 |
![]() |
047302.5YRT3 |
![]() |
0473005.YRT3 |
![]() |
0473007.YRT3 |
![]() |
0473003.YRT3 |
![]() |
0473002.YRT3 |
![]() |
047301.5YRT3 |
![]() |
0473001.YRT3 |
![]() |
0473.750YRT3 |
![]() |
0473.500YRT3 |
![]() |
0473.375YRT3 |
![]() |
0473001.MRT1 |
![]() |
0473.375YRT1 |
![]() |
04732.25YRT1 |
![]() |
04732.25YRT3 |
![]() |
047301.5MRT1 |
![]() |
047302.5MRT1 |
![]() |
0473003.MRT1 |
![]() |
047303.5MRT1 |
![]() |
0473004.MRT1 |
![]() |
0473005.MRT1 |
![]() |
0473004.YRT1 |
PDF Datasheet Preview |
---|
AXIAL LEAD AND CARTRIDGE FUSES SUBMINIATURE II Type Fuse The II fuse combines time delay performance characteristics with the proven reliability of a Picofuse. ELECTRICAL CHARACTERISTICS: % of Ampere Rating Opening Time 100% 4 hours, Minimum 200% 1 second, Min. 60 seconds, Max. 300% seconds, Min. 3 seconds, Max. 800% seconds, Min. seconds, Max. AGENCY APPROVALS 1 Recognized under the Components Program of Underwriters Laboratories and Certified by CSA. Approved by MITI from 1 through 5 amperes. AGENCY FILE NUMBERS UL E10480, CSA LR INTERRUPTING RATINGS 50 amperes at 125 VDC/VAC ENVIRONMENTAL SPECIFICATIONS Operating Temperature to 125°C. Shock MIL-STD-202, Method 213, Test Condition I 100 G’s peak for 6 milliseconds . Vibration MIL-STD-202, Method 201 Hz MIL-STD-202, Method 204, Test Condition C Hz at 10 G’s Peak . Salt Spray MIL-STD-202, Method 101, Test Condition B. Insulation Resistance After Opening MIL-STD-202, Method 302, 10,000 ohms minimum at 100 volts . Resistance to Soldering Heat MIL-STD-202, Method 210, Test Condition C 20 sec at 260°C . Thermal Shock MIL-STD-202, Method 107, Test Condition B to 125°C . Moisture Resistance MIL-STD-202, Method 106 RH , Heat 65°C . PHYSICAL SPECIFICATIONS Materials Encapsulated, Epoxy-Coated Body Solder Coated Copper Wire Leads. Flammability Rating UL94VO. Soldering Parameters: Wave Solder 260°C, 3 seconds maximum. Solderability MIL-STD-202, Method Lead Pull Force MIL-STD-202, Method 211, Test Condition A will withstand a 10 lb. axial pull test . PACKAGING SPECIFICATIONS Tape and Reel per EIA-296 T1 52.4mm taped spacing 4,000 per reel. PATENTED ORDERING INFORMATION: Catalog Number Ampere Rating Voltage Rating Nominal Resistance Cold Ohms Nominal Melting I2t A2 Sec. 473 001 11/2 473 002 21/4 21/2 473 003 31/2 473 004 473 005 473 007 TIME IN SECONDS DIA. REF. LF 1 A DIA. REF. .375A .50A .75A 1.0A 1.5A 2.0A 2.5A 3.0A 3.5A 4.0A 5.0A 7.0A Average Time Current Curves 1000 CURRENT IN AMPERES 1000 |
More datasheets: 0473005.YRT3 | 0473007.YRT3 | 0473003.YRT3 | 0473002.YRT3 | 047301.5YRT3 | 0473001.YRT3 | 0473.750YRT3 | 0473.500YRT3 | 0473.375YRT3 | 0473001.MRT1 |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived 0473004.YRT3 Datasheet file may be downloaded here without warranties.