Part | Datasheet |
---|---|
![]() |
43700000045000 (pdf) |
PDF Datasheet Preview |
---|
AA-150-24-44-LK-XX Outdoor Thermoelectric Cooler Assemblies With Bi-Polar Thermostatic Control THERMOELECTRIC COOLING UNITS FOR OUTDOOR ENCLOSURES AND KIOSKS The AA Outdoor Cooler Series is an Air-Air Thermoelectric Assembly TEA that uses impingement flow to transfer heat. It offers dependable, compact performance by cooling or heating enclosures via convection. A bi-polar thermostatic controller with predetermined set points is integrated into the TEA. The unit is programmed to cool when the temperature inside the enclosure exceeds 25°C, and heat when the internal temperature drops below 10°C. This product series has been designed to pass rigorous Telcordia test requirements conducted by our customers, such as earthquake resistance, salt fog, wind-driven rain, high temperature exposure and dust contaminants. This is due to the selection of world-class components such as brand name fans with the highest degree of environmental protection and lifetime guaranteed waterproof connectors, heavy duty anodization on the high-density heat sinks, overheat protection, and double environmental seals for the thermoelectric modules TEMs . • 150W capacity rated at = 0ºC, ambient = 32°C • Wide operating temperature range of -40°C to +55°C • Telcordia GR-487-CORE tested and verified by customers when integrated in telecom outdoor enclosures • Gaskets, connectors, and fans provide a NEMA 4 seal for the enclosure • UL 60950 and UL 50 approval obtained by customers when integrated in telecom outdoor enclosures • Environmentally friendly solid-state operation no compressor or CFC refrigerants • Bi-polar thermostatic control cooling mode > 25°C / heating mode < 10°C • Outdoor telecom enclosures • Outdoor kiosks and displays • Harsh condition electronic cabinets • Battery cabinets global solutions local support TM Americas Europe Asia: AA-150-24-44-LK-XX Outdoor Thermoelectric Cooler Assemblies With Bi-Polar Thermostatic Control PERFORMANCE Qc VS 5 10 15 20 25 30 35 40 dT °C SPECIFICATIONS Technical Technology Cooling at dT = 0°C, and nominal / float voltage.1 Heating 2 Voltage nominal / maximum Grounding all voltages Current draw, ±10% nominal / startup Weight Panel mounting Fan life L10 at +40°C Number of connectors Connector type on unit / mating side Hi-pot testing Environmental Temperature range 3 external ambient Temperature range internal enclosure Overheating thermostat Degree of protection, enclosure 4 Degree of protection, unit 5 Sound level 1m distance Over-Temp Thermostat hot and cold side heat sink LK-81 Bi-Polar Controller Regulation Thermostatic control set point Hysteresis Low voltage disconnect/reconnect LVD/LVD-R AA-150-24-44-LK-XX Thermoelectric modules, forced air, closed loop non-mixing , filterless, non-refrigerant 143/159W 488/543 Btu/h 150W 512 Btu/h 24/28 VDC Positive or negative A 24V version kg lbs Through hours 1 On unit AMP part number 350777-1, 794269, 350547-6, 794270-1 Mating side AMP part number 350778-1, 350550-6, 794270-1 707 VDC -40°C to +55°C -40°F to +131°F -20°C to +55°C -4°F to +131°F 80°C ± 3°C Hot and cold side heat sink surfaces NEMA 4 IP55 IP54 58 dB A 80°C ± 3°C On / Off Cooling 25°C +/- 2°C, Heating 10°C +/-2°C 3°C 22.5/24.8V +/- 0.5V 1 Cooling capacities at nominal / float voltage are rated at external temperatures of 32°C and 46°C respectively. Float voltage is defined at 27 VDC. 2 Heating capacity is rated at external temperature of -40°C, nominal voltage, and dT = -45°C. 3 Controller function shall not operate the external fan during heating mode. 4 The highest environmental protection level requires an external shroud and is defined as the protection level for the enclosure. 5 Rating for unit without protective shroud. Note The specified performance of any Laird Technologies cooling unit is dependent on how it is handled and incorporated into the final product. This includes elements such as the system design, insulation design, and assembly method. While Laird Technologies is able to provide general guidelines based upon our experience, it is ultimately the responsibility of the device manufacturer to validate each product and its performance for its intended use. AA-150-24-44-LK-XX Outdoor Thermoelectric Cooler Assemblies With Bi-Polar Thermostatic Control ISOMETRIC DRAWINGS Cold Side Warm Side MOUNTING HOLE LOCATION WIRING SCHEMATIC 330 ± 30 Electrical connections K1 Power to Bi-Polar Controller P1 Positive Red P2 Negative Black Marked -24VDC AA-150-24-44-LK-XX 0613 Any information furnished by Laird Technologies, Inc. and its agents is believed to be accurate and reliable. All specifications are subject to change without notice. Responsibility for the use and application of Laird Technologies materials rests with the end user, since Laird Technologies and its agents cannot be aware of all potential uses. Laird Technologies makes no warranties as to the fitness, merchantability or suitability of any Laird Technologies materials or products for any specific or general uses. Laird Technologies shall not be liable for incidental or consequential damages of any kind. All Laird Technologies products are sold pursuant to the Laird Technologies’ Terms and Conditions of sale in effect from time to time, a copy of which will be furnished upon request. Copyright 2010 Laird Technologies, Inc. All Rights Reserved. Laird, Laird Technologies, the Laird Technologies Logo, and other marks are trade marks or registered trade marks of Laird Technologies, Inc. or an affiliate company thereof. Other product or service names may be the property of third parties. Nothing herein provides a license under any Laird Technologies or any third party intellectual property rights. |
More datasheets: CA3102R20-27SW | HUFA75332G3 | HUFA75332S3ST | HUFA75332S3S | DDMC-24H7P-J-K87 | APTGT150A1202G | MDM-31SH006P | ISLRE-BDGSTKEV1Z | 76650-0134 | DBMMG17H2PJK87 |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived 43700000045000 Datasheet file may be downloaded here without warranties.