MDA 600-12N1 600-14N1 600-16N1 600-18N1 600-20N1 600-22N1
Part | Datasheet |
---|---|
![]() |
MDA600-22N1 (pdf) |
Related Parts | Information |
---|---|
![]() |
MDK600-16N1 |
![]() |
MDD600-18N1 |
![]() |
MDA600-20N1 |
![]() |
MDD600-12N1 |
![]() |
MDD600-16N1 |
![]() |
MDA600-12N1 |
![]() |
MDA600-14N1 |
![]() |
MDK600-20N1 |
![]() |
MDA600-18N1 |
![]() |
MDK600-22N1 |
![]() |
MDD600-20N1 |
![]() |
MDD600-22N1 |
![]() |
MDK600-12N1 |
![]() |
MDK600-14N1 |
![]() |
MDK600-18N1 |
![]() |
MDA600-16N1 |
PDF Datasheet Preview |
---|
IXYS Date Data Sheet Issue 3 Dual Diode Modules MD# 600 Absolute Maximum Ratings VRRM VDRM [V] 1200 1400 1600 1800 2000 2200 MDD 600-12N1 600-14N1 600-16N1 600-18N1 600-20N1 600-22N1 MDA 600-12N1 600-14N1 600-16N1 600-18N1 600-20N1 600-22N1 VRRM VRSM VOLTAGE RATINGS OTHER RATINGS IF AV M IF AV M IF AV M IF RMS IF d.c. ITSM ITSM2 I2t Visol Tj op Tj max Tstg Maximum average forward current. Tcase = 111°C 2 Maximum average forward current. Tcase = 85°C 2 Maximum average forward current. Tcase = 100°C 2 Nominal RMS forward current. Tcase = 55°C 2 D.C. forward current. Tcase = 55°C Peak non-repetitive surge tp = 10 ms, VRM = 60%VRRM 3 Peak non-repetitive surge tp = 10 ms, VRM 10 V 3 I2t capacity for fusing tp = 10 ms, VRM = 60%VRRM 3 I2t capacity for fusing tp = 10 ms, VRM 10 V 3 Isolation Voltage 4 Operating temperature range Maximum junction temperature Storage temperature range 1 De-rating factor of per °C is applicable for Tj below 25°C. 2 Single phase 50 Hz, 180° half-sinewave. 3 Half-sinewave, 150°C Tj initial. 4 AC RMS voltage, 50 Hz, 1min test. MDK 600-12N1 600-14N1 600-16N1 600-18N1 600-20N1 600-22N1 MAXIMUM LIMITS 1200-2200 1300-2300 UNITS MAXIMUM LIMITS 600 883 726 1818 1158 3500 -40 to +125 +150 -40 to +125 UNITS A kA A2s V °C °C °C Data Sheet. MD#600-12N1 to 22N1 Issue 3 Page 1 of 9 November, 2004 IXYS Characteristics PARAMETER VFM Maximum peak forward voltage VFM Maximum peak forward voltage VT0 Threshold voltage Slope resistance Qrr Recovered Charge Qra Recovered Charge, 50% chord RthJC Thermal resistance, junction to case RthCK Thermal resistance, case to heatsink Outline Drawing & Ordering Information Dual Diode Module Types MD#600-12N1 to MD#600-22N1 ORDERING INFORMATION Fixed Type Code Configuration code DD, DA, DK Average Current Rating Order code MDD configuration, 1400V VDRM, VRRM Please quote 11 digit code as below Voltage code VDRM/100 12-22 Standard diode Fixed Version Code IXYS Semiconductor GmbH Edisonstraße 15 D-68623 Lampertheim Tel +49 6206 503-0 Fax +49 6206 503-627 E-mail: IXYS IXYS Corporation 3540 Bassett Street Santa Clara CA 95054 USA Tel +1 408 982 0700 Fax +1 408 496 0670 E-mail: Westcode Semiconductors Ltd Langley Park Way, Langley Park, Chippenham, Wiltshire, SN15 1GE. Tel +44 0 1249 444524 Fax +44 0 1249 659448 E-mail: WESTCODE An IXYS Company Westcode Semiconductors Inc 3270 Cherry Avenue Long Beach CA 90807 USA Tel +1 562 595 6971 Fax +1 562 595 8182 E-mail: The information contained herein is confidential and is protected by Copyright. The information may not be used or disclosed except with the written permission of and in the manner permitted by the proprietors IXYS Semiconductors GmbH. In the interest of product improvement, IXYS reserves the right to change specifications at any time without prior notice. IXYS Semiconductor GmbH. Data Sheet. MD#600-12N1 to 22N1 Issue 3 Page 9 of 9 November, 2004 |
More datasheets: MDK600-16N1 | MDD600-18N1 | MDA600-20N1 | MDD600-12N1 | MDD600-16N1 | MDA600-12N1 | MDA600-14N1 | MDK600-20N1 | MDA600-18N1 | MDK600-22N1 |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived MDA600-22N1 Datasheet file may be downloaded here without warranties.