FWC3015-760F

FWC3015-760F Datasheet


FWC30 Series

Part Datasheet
FWC3015-760F FWC3015-760F FWC3015-760F (pdf)
Related Parts Information
FWC3009-760F FWC3009-760F FWC3009-760F
FWC3024-760F FWC3024-760F FWC3024-760F
FWC3012-760F FWC3012-760F FWC3012-760F
FWC3018-760F FWC3018-760F FWC3018-760F
PDF Datasheet Preview
FWC30 Series
30W ITE Desktop Power Supply

FWC30 Is Not Recommended For New Designs. Not Level VI Compliant. Not for Consumer / Household use for units built after February, Please Use FWE30 Class II or FWE30 Class I As A Replacement

High Efficiency Level V

Fully Regulated DC Output

Lifetime Expectation >5 years

Time >12ms at full load

Safety Approval Class I

CEC Compliant

Elpac Part Number

Output Voltage

Output Current

Peak Current1
9.0V
3.3A
3.9A
12.0V
2.5A
3.0A
15.0V
2.0A
2.4A
18.0V
1.7A
2.0A
24.0V
1.3A
1.5A

Notes
1 Maximum peak load 36W lasting 500ms with a maximum 10% duty cycle. 2 Includes initial setting, line regulation, load regulation, and thermal drift. 3 Typical at 115VAC including output cable .

Total Regulation2 ±5% ±5% ±5% ±5% ±5%

Typical Efficiency3 81% 83% 84% 85% 86%

Input Voltage Input Frequency Input Current Inrush Current Zero Load Power Consumption Touch Leakage Current
85 264VAC 100 240VAC Nominal 47 63Hz <1.0A rms <37A at 230VAC cold start <0.3W <250µA 132VAC 60Hz <400µA 264VAC 60Hz

Output

Output Voltage

See Table

Total Regulation

Minimum Load

No minimum load required

Delay
More datasheets: SRAH-05A500R | SRAH-05A330R | SRAH-05A1500 | SRAH-05A1800 | SRAH-05A250R | SRAH-05A120R | SRAH-05A1AFR | SRAH-05A1A0R | SRAH-05A180R | FWC3009-760F


Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived FWC3015-760F Datasheet file may be downloaded here without warranties.

Datasheet ID: FWC3015-760F 510979