FWC30 Series
Part | Datasheet |
---|---|
![]() |
FWC3015-760F (pdf) |
Related Parts | Information |
---|---|
![]() |
FWC3009-760F |
![]() |
FWC3024-760F |
![]() |
FWC3012-760F |
![]() |
FWC3018-760F |
PDF Datasheet Preview |
---|
FWC30 Series 30W ITE Desktop Power Supply FWC30 Is Not Recommended For New Designs. Not Level VI Compliant. Not for Consumer / Household use for units built after February, Please Use FWE30 Class II or FWE30 Class I As A Replacement High Efficiency Level V Fully Regulated DC Output Lifetime Expectation >5 years Time >12ms at full load Safety Approval Class I CEC Compliant Elpac Part Number Output Voltage Output Current Peak Current1 9.0V 3.3A 3.9A 12.0V 2.5A 3.0A 15.0V 2.0A 2.4A 18.0V 1.7A 2.0A 24.0V 1.3A 1.5A Notes 1 Maximum peak load 36W lasting 500ms with a maximum 10% duty cycle. 2 Includes initial setting, line regulation, load regulation, and thermal drift. 3 Typical at 115VAC including output cable . Total Regulation2 ±5% ±5% ±5% ±5% ±5% Typical Efficiency3 81% 83% 84% 85% 86% Input Voltage Input Frequency Input Current Inrush Current Zero Load Power Consumption Touch Leakage Current 85 264VAC 100 240VAC Nominal 47 63Hz <1.0A rms <37A at 230VAC cold start <0.3W <250µA 132VAC 60Hz <400µA 264VAC 60Hz Output Output Voltage See Table Total Regulation Minimum Load No minimum load required Delay |
More datasheets: SRAH-05A500R | SRAH-05A330R | SRAH-05A1500 | SRAH-05A1800 | SRAH-05A250R | SRAH-05A120R | SRAH-05A1AFR | SRAH-05A1A0R | SRAH-05A180R | FWC3009-760F |