Off-Line SMPS Current Mode Controller with integrated 500V Startup Cell

Power Management & Supply

Never stop thinking.
2005-09-02

Previous Version:1.1

Datasheet

For questions on technology, delivery and prices please contact the Infineon Technologies Offices in Germany or the Infineon Technologies Companies and Representatives worldwide see our webpage at

Edition 2005-09-02

Published by Infineon Technologies AG, St.-Martin-Strasse 53, D-81541 München

Infineon Technologies AG

All Rights Reserved.

Attention please!

The information herein is given to describe certain components and shall not be considered as warranted characteristics. Terms of delivery and rights to technical change reserved. We hereby disclaim any and all warranties, including but not limited to warranties of non-infringement, regarding circuits, descriptions and charts stated herein. Infineon Technologies is an approved CECC manufacturer.

Information

For further information on technology, delivery terms and conditions and prices please contact your nearest Infineon Technologies Office in Germany or our Infineon Technologies Representatives worldwide see address list .

Warnings

Due to technical requirements components may contain dangerous substances. For information on the types in question please contact your nearest Infineon Technologies Office. Infineon Technologies Components may only be used in life-support devices or systems with the express written approval of Infineon Technologies, if a failure of such components can reasonably be expected to cause the failure of that life-support device or system, or to affect the safety or effectiveness of that device or system. Life support devices or systems are intended to be implanted in the human body, or to support and/or maintain and sustain and/or protect human life. If they fail, it is reasonable to assume that the health of the user or other persons may be endangered.

ICE3AS02 / ICE3BS02 ICE3AS02G / ICE3BS02G

Off-Line SMPS Current Mode Controller with integrated 500V Startup Cell

Product Highlights
• Active Burst Mode to reach the lowest Standby Power Requirements < 100mW

PG-DIP-8 test
• Protection features Auto Restart Mode to increase
robustness and safety of the system
• Adjustable Blanking Window for high load jumps to increase
system reliability
• PB-free Plating and RoHS compilant

PG-DSO-8

P-DSO-8-3, -6
• 500V Startup Cell switched off after Start Up
• Active Burst Mode for lowest Standby Power
light load controlled by Feedback Signal
• Fast load jump response in Active Burst Mode
• 100/67kHz internally fixed switching frequency
• Auto Restart Mode for Overtemperature Detection
• Auto Restart Mode for VCC Overvoltage Detection
• Auto Restart Mode for Overload and Open Loop
• Auto Restart Mode for VCC Undervoltage
• Blanking Window for short duration high current
• User defined Soft Start
• Minimum of external components required
• Max Duty Cycle 72%
• Overall tolerance of Current Limiting < ±5%
• Internal PWM Leading Edge Blanking
• Soft switching for low EMI

The F3 Controller provides Active Burst Mode to reach the lowest Standby Power Requirements <100mW at no load. As the controller is always active during Active Burst Mode, there is an immediate response on load jumps without any black out in the SMPS. In Active Burst Mode the ripple of the output voltage can be reduced Furthermore, to increase the robustness and safety of the system, the device enters into Auto Restart Mode in the cases of Overtemperature, VCC Overvoltage, Output Open Loop or Overload and VCC Undervoltage. By means of the internal precise peak current limitation, the dimension of the transformer and the secondary diode can be lowered which leads to more cost efficiency. An adjustable blanking window prevents the IC from entering Auto Restart Mode or Active Burst Mode unintentionally in case of high load jumps.
85 270 VAC GND

CBulk HV

Startup Cell

Power Management

CVCC

PWM Controller Current Mode

Precise Low Tolerance Peak Current Limitation

Control Unit
More datasheets: DG509ADY-T | DG509ACWE | ICS650R-21 | ICS650R-21I | ICS650R-21IT | ICS650R-21T | D25P13A6GV4BLF | ICE3BS02 | ICE3AS02 | ICE3BS02G


Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived ICE3AS02G Datasheet file may be downloaded here without warranties.

Datasheet ID: ICE3AS02G 638052