CV120300 CV120600 CV1201200 CV1201800
Part | Datasheet |
---|---|
![]() |
CV1201200 (pdf) |
Related Parts | Information |
---|---|
![]() |
CV120300 |
![]() |
CV1201800 |
![]() |
CV120600 |
PDF Datasheet Preview |
---|
Quality Products. Service Excellence. Constant Voltage - AC Regulator +/- 120VAC to 120VAC CV Series Plug-In Note This product line has been discontinued as a stocked series. Information is for reference only. For alternative solution assistance, please contact Hammond Customer Service - or USA 716 630-7030, Canada and International 519 AC regulating - protects against both brownouts & over voltage conditions. Protects against any power problem other than a blackout. Will operate through a 3 millisecond minimum blackout. Long life - ferroresonant design - no moving parts. Ferroresonant design also filters out surges, line harmonics, and RF noise. Input 120VAC +10 % to -25 % , 60 Hz Output 120VAC +/- 3 Provides circuit isolation. Noise Isolation RF of 120 db common mode, 60 db normal mode. Spike attenuation 250:1 minimum. Sine wave output - total harmonic distortion THD 3 % Units also include a 2nd stage of high frequency filtering on the output - a Hammond Mfg. exclusive. Operating temperature range of -40 degrees C to +40 degrees C. Standard 3-wire, grounded plug & receptacle. Front panel lighted power switch. Input primary connected to an extra long 15 foot, heavy duty 14/3 SJTW cord for extreme temperature ranges. Integral molded, standard North American plug NEMA 5-15P . Output secondary connected to a rear mounted, standard North American, grounded receptacle NEMA 5-15R - quantity depends on power capacity of unit see table below . Rugged two piece ventilated steel enclosure. Finished in a grey/beige color, textured powder paint with rubber feet installed. NOTE 1 Due to the nature of ferroresonant designs - these units do produce audible noise. We have reduced this through careful design, but these units are NOT usable in an office environment. NOTE 2 These units provide complete isolation from the source voltage. In other words, the "neutral" output wire has no connection to ground, this is a UL requirement for this type of device. Therefore plug-in circuit testers & line "polarity" testing devices will NOT function on the output as it is completely isolated. North American Mark of Safety C UL & UL listed File #E211544 . Indoor use only. Gallery Accessories International Grounded Adaptor Plugs CV120300 CV120600 CV1201200 CV1201800 300 600 1200 1800 Capacity Amps RMS 5 10 15 Outlet Qty Hammond Manufacturing Ltd. All rights reserved. Overall Dimensions Weight Lbs 48 74 95 Data subject to change without notice. |
More datasheets: V9-20S43D900 | V9-25S43D906A | V9-20S23D900 | V9-16S43D905A | V9-11S43D800 | V9-16S23D800 | LTL-94PCK-TA | DDMMZ36X4SN | CV120300 | CV1201800 |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived CV1201200 Datasheet file may be downloaded here without warranties.