QW030xx DUAL Series Power Modules dc-dc Converters 18 Vdc to 36 Vdc or 36 Vdc to 75 Vdc Inputs
Part | Datasheet |
---|---|
![]() |
QW030AJ1 (pdf) |
Related Parts | Information |
---|---|
![]() |
QW030CL1 |
![]() |
QW030BK1 |
PDF Datasheet Preview |
---|
Data Sheet October 2008 QW030xx DUAL Series Power Modules dc-dc Converters 18 Vdc to 36 Vdc or 36 Vdc to 75 Vdc Inputs The QW030-Series Power Modules use advanced, surfacemount technology and deliver high-quality, efficient, and compact dc-dc conversion. n Distributed power architectures n Workstations n Computer equipment n Communications equipment n Optical transport equipment Options n Heat sinks available for extended operation n Choice of remote on/off logic configurations n Choice of two pin lengths n Small size mm x mm x mm in. x in. x in. n High power density n High efficiency 88% typical n Low output noise n Constant frequency n Industry-standard pinout n Metal case n 2:1 input voltage range n Overvoltage and overcurrent protection n Remote on/off n Adjustable output voltage n ISO* 9001 and ISO 14001 Certified manufacturing facilities n UL† 60950 Recognized, C22.2 No. 60950-00 Certified, VDE § 0805 IEC60950 Licensed n CE mark meets 73/23/EEC and 93/68/EEC directives** * ISO is a registered trademark of the International Organization for Standardization. † UL is a registered trademark of Underwriters Laboratories, Inc. CSA is a registered trademark of Canadian Standards Assn. § VDE is a trademark of Verband Deutscher Elektrotechniker e.V. **This product is intended for integration into end-use equipment. All the required procedures for CE marking of end-use equipment should be followed. The CE mark is placed on selected products. The QW030-Series Power Modules are dc-dc converters that operate over an input voltage range of 36 Vdc to 75 Vdc and provide precisely regulated dc outputs. The outputs are fully isolated from the inputs, allowing versatile polarity configurations and grounding connections. The modules have maximum power ratings of 30 W to 36 W at a typical full-load efficiency of up to These encapsulated modules offer a metal case for optimum thermal performance. Threaded-through holes are provided to allow easy mounting or addition of a heat sink for high-temperature applications. The standard feature set includes remote sensing, output trim, and remote on/off for convenient flexibility in distributed power applications. QW030xx DUAL Series Power Modules dc-dc Converters 18 Vdc to 36 Vdc or 36 Vdc to 75 Vdc Inputs Data Sheet October 2008 Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only. Functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect device reliability. Input Voltage Continuous Parameter Transient 100 ms Operating Case Temperature See Thermal Considerations section. Storage Temperature I/O Isolation Voltage Note case is tied to input Device Symbol QW030xx QW030xx VI, trans QW030xx QW030xx Tstg QW030xx Unit 105* The temperature at this location should not exceed 105 °C. The output power of the module should not exceed the rated power for the module as listed in the Ordering Information table. Although the maximum case temperature of the power modules is 105 °C, you can limit this temperature to a lower value for extremely high reliability. Input Undervoltage Lockout At input voltages below the input undervoltage lockout limit, the module operation is disabled. The module will begin to operate at an input voltage between the undervoltage lockout limit and the minimum operating input voltage. Lineage Power Data Sheet October 2008 QW030xx DUAL Series Power Modules dc-dc Converters 18 Vdc to 36 Vdc or 36 Vdc to 75 Vdc Inputs Thermal Considerations continued Heat Transfer Without Heat Sinks Increasing airflow over the module enhances the heat transfer via convection. Figures 8 and 10 show the maximum power that can be dissipated by the module without exceeding the maximum case temperature versus local ambient temperature TA for natural convection through 3 m/s 600 ft./min. . Systems in which these power modules may be used typically generate natural convection airflow rates of 60 ft./min. due to other heat-dissipating components in the system. Therefore, the natural convection condition represents airflow rates of up to 60 ft./min. . Use of Figure 8 is shown in the following example. Example What is the minimum airflow necessary for a QW030BK operating at VI = 48 V, an output current of A, each and a maximum ambient temperature of 89 °C? Solution Given VI = 48 V IO1 = A, IO2 = A TA = 89 °C Determine PD Use Figure 9 : PD = W Determine airflow v Use Figure 8 v = m/s 600 ft./min. POWER DISSIPATION, PD W MAX CASE TEMP. m/s 600 ft./min. m/s 400 ft./min. m/s 200 ft./min. NATURAL CONVECTION 40 50 60 70 80 90 100 110 LOCAL AMBIENT TEMPERATURE, TA C 1-0206 Figure QW030BK POWER DERATING CURVE POWER DISSIPATION, PD W 6 VI = 75 V 5 VI = 48 V VI = 36 V OUTPUT CURRENT, IO1 = IO2 A 1-0204 Figure QW030BK Power dissipation With Balanced Loads POWER DISSIPATION, PD W 6 VI = 75 V 5 VI = 48 V VI = 36 V OUTPUT CURRENT, IO2 A 1-0205 Figure QW030BK Power Dissipation with Unbalanced Loads with Io1 = A Lineage Power QW030xx DUAL Series Power Modules dc-dc Converters 18 Vdc to 36 Vdc or 36 Vdc to 75 Vdc Inputs Data Sheet October 2008 Ordering Information Please contact your Lineage Power Account Manager or Field Application Engineer for pricing and availability. Table Device Codes Input Voltage 48 Vdc 48 Vdc 48 Vdc Output Voltage +12, -12 +15, -15 +5, -5 Output Power 36W 30W Output Current 2.5A, 2.5A 1.75A, 1.75A 3A, 3A Remote On/ Off Logic Negative Device Code QW030BK1 QW030CL1 QW030AJ1 Comcode 108958885 108962176 108963687 Table Device Options Option Short pins mm ± mm in. ± in. Short pins mm ± mm in. ± in. Negative logic On/Off Device Code Suffix 8 Lineage Power QW030xx DUAL Series Power Modules dc-dc Converters;OOct 18 Vdc to 36 Vdc or 36 Vdc to 75 Vdc Inputs Advance Data Sheet April 2008 A sia-Pacific Head qu art ers T el +65 6 41 6 4283 World W ide Headq u arters Lin eag e Po wer Co rp oratio n 30 00 Sk yline D rive, Mesquite, T X 75149, U SA +1-800-526-7819 Outs id e U .S.A +1- 97 2-2 84 -2626 ag ep ower.co m e-m ail tech sup lin ea gep ower.co m Eu ro pe, M id dle-East an d Afric a He ad qu arters Tel +49 8 9 6089 286 Ind ia Head qu arters Tel +91 8 0 28411633 Lineage Power reserves the right to make changes to the produc t s or information contained herein without notice. No liability is ass umed as a res ult of their use or applic ation. No rights under any patent acc ompany the sale of any s uc h pr oduct s or information. 2008 Lineage Power Corpor ation, Mesquite, Texas All International Rights Res er ved. October 2008 ADS01-046EPS Replaces ADS01-045EPS |
More datasheets: DRM4000-N00-USB-EVAL | CMUHFF58 | DEMAY9PNMBK52 | DTZ.126.GAET06 | DTZ.127.GAET06 | DTZ.125.GAET06 | DCC.91.517.0L | DWZ.F99.SA | 76650-0115 | QW030CL1 |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived QW030AJ1 Datasheet file may be downloaded here without warranties.