FW300F1

FW300F1 Datasheet


FW250F1 and FW300F1 Power Modules dc-dc Converters 36 to 75 Vdc Input, Vdc Output 165 W to 198 W

Part Datasheet
FW300F1 FW300F1 FW300F1 (pdf)
Related Parts Information
FW250F1 FW250F1 FW250F1
PDF Datasheet Preview
Data Sheet July 2002

FW250F1 and FW300F1 Power Modules dc-dc Converters 36 to 75 Vdc Input, Vdc Output 165 W to 198 W

The FW250F1 and FW300F1 Power Modules use advanced, surface-mount technology and deliver high-quality, compact, dc-dc conversion at an economical price.
• Redundant and/or distributed power architectures
• Telecommunications
• Data processing

Options
• Heat sinks available for extended operation
• Size mm x mm x mm in. x in. x in.
• Wide input voltage range
• High efficiency 79% typical
• Parallel operation with load sharing
• Output voltage set-point adjustment trim
• Thermal protection
• Synchronization
• Power good signal
• Output current monitor
• Output overvoltage and overcurrent protection
• Constant frequency
• Case ground pin
• Input-to-output isolation
• Remote sense
• Remote on/off
• Short-circuit protection
• Output overvoltage clamp
• ISO9001 Certified manufacturing facilities
• UL* 60950 Recognized, CSA† No. 60950-00

Certified, VDE 0805 IEC60950, 3rd ed. Licensed
• CE mark meets 73/23/EEC and 93/68/EEC

The FW250F1 and FW300F1 Power Modules are dc-dc converters that operate over an input voltage range of 36 Vdc to 75 Vdc and provide a precisely regulated dc output. The outputs are fully isolated from the inputs, allowing versatile polarity configurations and grounding connections. The modules have maximum power ratings from 250 W to 300 W at a typical full-load efficiency of

Two or more modules may be paralleled with forced load sharing for redundant or enhanced power applications. The package, which mounts on a printed-circuit board, accommodates a heat sink for high-temperature applications.
* UL is a registered trademark of Underwriters Laboratories, Inc. † CSA is a registered trademark of Canadian Standards Association. This product is intended for integration into end-use equipment. All the required procedures for CE marking of end-use equipment should
be followed. The CE mark is placed on selected products.

FW250F1 and FW300F1 Power Modules dc-dc Converters 36 to 75 Vdc Input, Vdc Output 165 W to 198 W

Data Sheet July 2002

Absolute Maximum Ratings

Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only. Functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect device reliability.

Parameter

Input Voltage Continuous Transient 100 ms

VI, trans

I/O Isolation Voltage

Operating Case Temperature

See Thermal Considerations section and

Figure

Storage Temperature

Tstg
80 100 1500 100

Unit

V °C

Electrical Specifications

Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions.

Table Input Specifications

Parameter Operating Input Voltage Maximum Input Current VI = 0 V to 75 V :

FW250F1 FW300F1 Inrush Transient Input Reflected-ripple Current, Peak-to-peak 5 Hz to 20 MHz, 12 µH source impedance see Figure Input Ripple Rejection 120 Hz

Unit

II, max

II, max
mAp-p

Fusing Considerations

CAUTION This power module is not internally fused. An input line fuse must always be used.

This encapsulated power module can be used in a wide variety of applications, ranging from simple stand-alone operation to an integrated part of a sophisticated power architecture. To preserve maximum flexibility, internal fusing is not included however, to achieve maximum safety and system protection, always use an input line fuse. The safety agencies require a normal-blow, dc fuse with a maximum rating of 20 A see Safety Considerations section . Based on the information provided in this data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating can be used. Refer to the fuse manufacturer’s data for further information.
The temperature at this location should not exceed 100 °C. The maximum case temperature can be limited to a lower value for extremely high reliability. The output power of the module should not exceed the rated power for the module as listed in the Ordering Information table.

For additional information about these modules, refer to the Thermal Management for FC- and FW-Series 250 W Board-Mounted Power Modules Technical Note TN96-009EPS .

Tyco Electronics Corp..

Data Sheet July 2002

FW250F1 and FW300F1 Power Modules dc-dc Converters 36 to 75 Vdc Input, Vdc Output 165 W to 198 W

Thermal Considerations continued

Heat Transfer Without Heat Sinks

Derating curves for forced-air cooling without a heat sink are shown in Figures 25 and These curves can be used to determine the appropriate airflow for a given set of operating conditions. For example, if the unit with airflow along its length dissipates 20 W of heat, the correct airflow in a 40 °C environment is m/s 200 ft./min. .

POW ER DISSIPAT ION, PD W
m/s 800 ft./ min.
m/s 700 ft./ min.
m/s 600 ft./ min.
m/s 500 ft./ min.
m/s 400 ft./ min.
m/s 300 ft./ min.
m/s 200 ft./ min.
m/s 100 ft./ min. 30
10 1 m/ s 20 ft./min. NA T. CONV.
0 10 20 30 40 50 60 70 80 90 1 00

LOCAL AMBIENT T EMPERAT URE, TA
8-1315 C

Figure Convection Power Derating with No Heat Sink Airflow Along Width Transverse

POW ER DISSIPAT ION, PD W
70 m/s 800 ft./min
m/s 700 ft./min
m/s 600 ft./min
m/s 500 ft./min m/s 400 ft./min
m/s 300 ft./min
m/s 200 ft./min
m/s 100 ft./min 30
10 m/s 20 ft. /min. NAT CO NV.
0 10 20 30 40 50 60 70 80 90 1 00

LOCAL AMBIENT T EMPERATURE, TA
8-1314 C

Figure Convection Power Derating with No Heat Sink Airflow Along Length Longitudinal

Heat Transfer with Heat Sinks

The power modules have through-threaded, M3 x mounting holes, which enable heat sinks or cold plates to be attached to the module. The mounting torque must not exceed N-m 5 in.-lb. . For the screw attachment from the pin side, the recommended hole size on the customer’s PWB around the mounting holes is ± inches. If a larger hole is used, the mounting torque from the pin side must not exceed N-m in.-lbs. .

Thermal derating with heat sinks is expressed by using the overall thermal resistance of the module. Total module thermal resistance is defined as the maximum case temperature rise max divided by the module power dissipation PD :

The location to measure case temperature TC is shown in Figure Case-to-ambient thermal resistance vs. airflow for various heat sink configurations is shown in Figure 27 and Figure These curves were obtained by experimental testing of heat sinks, which are offered in the product catalog.

CASE-TO-AMBIENT THERMAL RESISTANCE, RCA
1/2 IN. HEAT SINK 1 IN. HEAT SINK 1/2 IN. HEAT SINK 1/4 IN. HEAT SINK NO HEAT SINK
Ordering Information

Input Voltage 48 V 48 V

Output Voltage V

Output Power 165 W 198 W

Device Code FW250F1 FW300F1
8-1650 C

Comcode 107859886 107253163

Tyco Electronics Corp..

FW250F1 and FW300F1 Power Modules dc-dc Converters 36 to 75 Vdc Input, Vdc Output 165 W to 198 W

Data Sheet July 2002
Ordering Information continued

Table Device Accessories

Accessory 1/4 in. transverse kit heat sink, thermal pad, and screws 1/4 in. longitudinal kit heat sink, thermal pad, and screws 1/2 in. transverse kit heat sink, thermal pad, and screws 1/2 in. longitudinal kit heat sink, thermal pad, and screws 1 in. transverse kit heat sink, thermal pad, and screws 1 in. longitudinal kit heat sink, thermal pad, and screws 1/2 in. transverse kit heat sink, thermal pad, and screws 1/2 in. longitudinal kit heat sink, thermal pad, and screws

Comcode
847308335 847308327 847308350 847308343 847308376 847308368 847308392 847308384
1/4 IN. 1/2 IN.
1 IN.
1/2 IN.

Figure Longitudinal Heat Sink
8-2830
1/4 IN. 1/2 IN.
1 IN.
1/2 IN.

Figure Transverse Heat Sink
8-2831

World Wide Headquarters Tyco Electronics Power Systems, Inc.
3000 Skyline Drive, Mesquite, TX 75149, USA +1-800-526-7819 FAX +1-888-315-5182 Outside U.S.A. +1-972-284-2626, FAX +1-972-284-2900 e-mail:

Europe, Middle-East and Africa Headquarters Tyco Electronics UK Ltd Tel +44 0 1344 469 300, Fax +44 0 1344 469 301

Central America-Latin America Headquarters Tyco Electronics Power Systems Tel +54 11 4316 2866, Fax +54 11 4312 9508

Asia-Pacific Headquarters Tyco Electronics Singapore Pte Ltd Tel +65 482 0311, Fax 65 480 9299

Tyco Electronics Corporation reserves the right to make changes to the product s or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product s or information.
2001 Tyco Electronics Power Systems, Inc. Mesquite, Texas All International Rights Reserved. Printed in U.S.A.

July 2002 FDS02-042EPS Replaces DS97-519EPS

Printed on Recycled Paper