Fluke Norma 4000/5000
Part | Datasheet |
---|---|
![]() |
FLUKE-N4K 3PP42IB (pdf) |
Related Parts | Information |
---|---|
![]() |
FLUKE-N5K 6PP50IP |
![]() |
FLUKE-N5K 6PP50I |
![]() |
FLUKE-N5K 3PP64I |
![]() |
FLUKE-N5K 3PP64IR |
![]() |
FLUKE-N5K 6PP42IBR |
![]() |
FLUKE-N5K 3PP54I |
![]() |
FLUKE-N5K 3PP64IP |
![]() |
FLUKE-N5K 6PP54I |
![]() |
FLUKE-N5K 6PP50IR |
![]() |
FLUKE-N5K 3PP64IPR |
![]() |
FLUKE-N5K 6PP54IR |
![]() |
FLUKE-N5K 6PP54IPR |
![]() |
FLUKE-N5K 3PP64 |
![]() |
FLUKE-N5K 3PP50IP |
![]() |
FLUKE-N5K 3PP54IR |
![]() |
FLUKE-N4K 3PP42IPB |
![]() |
FLUKE-N5K 3PP64R |
![]() |
FLUKE-N4K 3PP42IP |
![]() |
FLUKE-N4K 3PP50I |
![]() |
FLUKE-N5K 3PP54IP |
![]() |
FLUKE-N5K 6PP42IB |
![]() |
FLUKE-N5K 3PP50I |
![]() |
FLUKE-N5K 4PP54IP |
![]() |
FLUKE-N5K 4PP54 |
![]() |
FLUKE-N4K 3PP50IP |
![]() |
FLUKE-N5K 6PP64I |
![]() |
FLUKE-N5K 3PP54 |
![]() |
FLUKE-N4K 1PP42 |
![]() |
FLUKE-N4K 3PP42 |
![]() |
FLUKE-N4K 3PP50 |
![]() |
FLUKE-N5K 3PP50 |
![]() |
FLUKE-N5K 3PP54R |
![]() |
FLUKE-N4K 3PP42I |
![]() |
FLUKE-N4K 3PP52IB |
![]() |
FLUKE-N5K 6PP54IP |
![]() |
FLUKE-N4K 3PP54I |
![]() |
FLUKE-N4K 3PP42B |
![]() |
FLUKE-N5K 6PP64IPR |
![]() |
FLUKE-N5K 6PP64IP |
![]() |
FLUKE-N5K 6PP64IR |
![]() |
FLUKE-N4K 3PP54IP |
![]() |
FLUKE-N5K 6PP50IPR |
PDF Datasheet Preview |
---|
Fluke Norma 4000/5000 High Precision Power Analyzers Reliable, highly accurate measurements for the test & development of power electronics Compact Fluke Norma Series power analyzers include the latest power measurement technology to assist engineers working with motors, inverters, lighting, power supplies, transformers and automotive components in making their products more Based on a patented high-bandwidth architecture, Fluke Norma Series power analyzers deliver precise measurements of single or threephase current and voltage, harmonics analysis, Fast Fourier Transformation FFT analysis, as well as calculations of power and other derived values. They provide class-leading accuracy and common mode rejection for any waveform, frequency, or phase shift. Technical Data • Fluke Norma 4000: Ideal for testing, the Fluke Norma 4000 power analyzer offers easy and straight-forward operation. Features include 1 to 3 power phases, / 144 mm color display, harmonic analysis, FFT analysis, scope mode, vector diagram display, recorder function, Fluke NormaView PC software, and 4 MB RAM data memory. • Fluke Norma 5000: Providing the highest bandwidth on the market, the Fluke Norma 5000 power analyzer is the ideal test and analysis tool for the development of frequency converters and lighting equipment. Features include 1 to 6 power phases, optional internal printer, and all of the features and functionality of the Fluke Norma 4000 power analyzer described above. Fluke Norma Series power analyzers at a glance Number of Phases Bandwidth Basic Accuracy Sampling Rate Voltage Input Range Current Input Range direct, not via shunt Current Input Range via shunt Display Measured data memory for Settings Fast Fourier Transformation FFT RS232 Interface PI1 Process Interface 8 analog / impulse inputs and 4 analog outputs IEEE 488/GPIB Interface Fluke NormaView PC Software for data download, analysis Fluke Norma 4000 Fluke Norma 5000 1 or 3 3, 4 or 6 dc to 3 MHz or dc to 10 MHz depending on input module or depending on input modules MHz or 1 MHz depending on input modules to 1000 V mA 20 A depending on input module Table Shunts on page 10 Color, / 144 mm - 320 x 240 pixel Standard To the 40th harmonic Standard Optional Optional Standard Fluke Norma Series power analyzers -- optimum requires precise measurements Key Features • Compact, high precision power analyzers easy to carry and save working space. • Simple user interface ensures easy, intuitive operation. • Standard allow users to specify the exact functionality required for their own unique application. • Accurately display dynamic events on all phases at exactly the same point in time with simultaneous parallel acquisition of all phases. • All inputs are galvanically isolated to avoid short circuits in all applications. • Voltage, current and power harmonics up to the 40th. • FFT analysis, vector diagram display, recorder function Ordering Information Fluke Norma 4000 Basic Fluke Norma 4000 High Precision Power Analyzer Basic includes • Power supply cable • / 144 mm Color display • RS232/USB interface for data download • Space for three power-phases and options • Fluke NormaView PC software • Color user’s manual • Test with measurement values full point is Test with measurement values Fluke Norma 5000 Basic Fluke Norma 5000 High Precision Power Analyzer Basic includes • Power supply cable • / 144 mm Color display • Internal printer optional • RS232/USB interface for data download • Space for six power-phases and options • Fluke NormaView PC software • Color user’s manual • Test with measurement values full point is Test with measurement values Recommended Accessories Shunts The input modules can take up to 10 A or 20 A directly or measure current via wideband precision shunts. The available range of shunts enable measurements up to 1500 A and can be used in conjunction with all of the available input modules. Order Number 3024677 3024689 3024886 3024899 3024847 3024858 3024864 3024873 3024692 3313059 3313067 Description 32 A Planar Shunt, Imax 32A Cables for 32 A Planar Shunt 10 A Triaxial Shunt with Cables, Imax 30A 10 0 to 2 MHz 30 A Triaxial Shunt with Cables, Imax 100A 0 to 2 MHz 100 A Shunt with Cables, Imax 300A 0,2 0 to 1 MHz 150 A Shunt with Cables, Imax 450A 0 to MHz 300 A Shunt with Cables, Imax 1000A 0,06 0 to 0,5 MHz 500 A Shunt with Cables, Imax 1500A 0,06 0 to MHz LG Shunt Cables for High Current Shunts Fluke Norma 4000,19 inch rack mount kit with handles Fluke Norma 5000,19 inch rack mount kit with handles Cables & Adaptors Order Number 3024661 3024704 Description Measurement Cable Set for one power phase Fluke Norma WYE Adaptor external accessory box Printer Accessories Order Number 3024650 3024781 Printer Cable for Fluke Norma 5000 and Fluke Norma 4000 RS232-Centronics Norma Printer Paper All accessories have a two-year warranty. 10 Fluke Corporation Fluke Norma 4000/5000 power analyzers Standard Order Short Description number 3108534 3108541 3108552 3108565 3110957 3110969 3110978 3108576 3108583 3108590 3312894 3108601 3108612 3108620 3108635 3108647 3108658 3108664 3312934 3108673 3312941 3108686 3108699 3108702 3312952 3312965 3312976 3108716 3108725 3312929 Fluke-N4K 1PP42 Fluke-N4K 3PP42 Fluke-N4K 3PP42I Fluke-N4K 3PP42IP |
More datasheets: FLUKE-N5K 6PP50IR | FLUKE-N5K 3PP64IPR | FLUKE-N5K 6PP54IR | FLUKE-N5K 6PP54IPR | FLUKE-N5K 3PP64 | FLUKE-N5K 3PP50IP | FLUKE-N5K 3PP54IR | FLUKE-N4K 3PP42IPB | FLUKE-N5K 3PP64R | FLUKE-N4K 3PP42IP |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived FLUKE-N4K3PP42IB Datasheet file may be downloaded here without warranties.