B88069X3120T702

B88069X3120T702 Datasheet


T30-A90XG B88069X3120T702

Part Datasheet
B88069X3120T702 B88069X3120T702 B88069X3120T702 (pdf)
PDF Datasheet Preview
Surge arrester
3-electrode arrester
Series/Type Ordering code:

Version/Date Version:

T30-A90XG B88069X3120T702

Issue 04 / 2007-10-31 01

Content of header bars 1 and 2 of data sheet will be automatically entered in headers and footers! Please fill in the table and then change the color to "white" or invisible . This ensures that the table disappears for the customer PDF. To update the data sheet, click on the symbol "Preview" and then "Close". Please do not alter the header or footer when copying the content.

Identification/Classification 1 header 1 + top left header bar

Surge arrester

Identification/Classification 2 header 2 + bottom left header bar
3-electrode arrester
Ordering code top right header bar

B88069X3120T702

Series/Type top right header bar

T30-A90XG

Preliminary data optional if necessary

Department:

KB AB E / KB AB PM

Date:

Issue 04 / 2007-10-31

EPCOS AG Reproduction, publication and dissemination of this document, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited.

Surge arrester 3-electrode arrester

B88069X3120T702 T30-A90XG

Very small size Extremely fast response time High current rating Stable performance over life Extremely low capacitance High insulation resistance RoHS-compatible

Modem Data lines

Electrical specifications

DC spark-over voltage 1 2 3 DC spark-over voltage 3 5 DC spark-over voltage 2 4

Impulse spark-over voltage at 1 kV/µs - for 99 % of measured values 3 - for 50 % of measured values 3
at 1 kV/µs
- for 99 % of measured values 4 - for 50 % of measured values 4

Insulation resistance at 50 Vdc 3 Capacitance at 1 MHz 3

Service life 10 operations 10 operations 1 operation 10 operations 10 operations 1 operation 1 operation
50 Hz 1 s 7 50 Hz 1 s 6 50 Hz s 9 cycles 6 8/20 µs 7 8/20 µs 6 8/20 µs 6 10/350 µs 6

After service life Insulation resistance at 50 Vdc 3 8

DC spark-over voltage 2 3 DC spark-over voltage 2 4

Impulse spark-over voltage at 1 kV/µs - for 99 % of measured values 3
- for 99 % of measured values 4

Activation after reflow soldering 9
1 operation

URMS = 600 V 1 s

Weight

Operation and storage temperature

Climatic category IEC 60068-1

KB AB E / KB AB PM

Please read Cautions and warnings and Important notes at the end of this document.

Page 2 of 5
72 108 72 180 72 230
< 450 < 350 < 700 < 600 > 10 <
5 10 30 5 10 2
> 10 65 150 65 250
< 700 < 900
2 ~ -40 +90 40/ 90/ 21
More datasheets: 95079-15CA | 95079-10FA | 95079-10CAH | 95079-15DA | 95079-05FA | KIT0112 | 67-31B/GHC-YX2Y2MZ3/2T | FAN5093MTC | FAN5093MTCX | FJN4309RBU


Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived B88069X3120T702 Datasheet file may be downloaded here without warranties.

Datasheet ID: B88069X3120T702 511737