B88069X2890C102

B88069X2890C102 Datasheet


A83-A600X B88069X2890C102

Part Datasheet
B88069X2890C102 B88069X2890C102 B88069X2890C102 (pdf)
PDF Datasheet Preview
Surge arrester
2-electrode arrester
Series/Type Ordering code:

Date Version:

A83-A600X B88069X2890C102
2015-04-20 03

Content of header bars 1 and 2 of data sheet will be automatically entered in headers and footers! Please fill in the table and then
change the color to "white". This ensures that the table disappears invisible for the customer PDF.

Don't change formatting when entering or pasting text in the table and don't add any cell or line in and to it!

Identification/Classification 1

Surge arrester
header 1 + top left bar :

Identification/Classification 2
2-electrode arrester
header 2 + bottom left header bar :
Ordering code top right header bar

B88069X2890C102

Series/Type bottom right header bar

A83-A600X

Preliminary data optional :

Department:

PPD AB PD / PPD AB PM

Date:
2015-04-20

Version:

EPCOS AG Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited.

EPCOS AG is a TDK Group Company.

Surge arrester 2-electrode arrester

B88069X2890C102 A83-A600X

Standard size Fast response time High current rating Stable performance over life Very low capacitance High insulation resistance RoHS-compatible

Branch exchange MDF Line protection Subscriber protection

Electrical specifications

DC spark-over voltage 1 2 Tolerance Min. Max.
±20

Impulse spark-over voltage
at 100 V/µs - for 99% of measured values
< 1100
- typical values of distribution
< 950
at 1 kV/µs - for 99% of measured values
< 1400
- typical values of distribution
< 1100

Service life
10 operations 50 Hz, 1 s
1 operations 50 Hz, s 9 cycles
10 operations 8/20 µs
1 operation
8/20 µs
1 operation
10/350 µs
300 operations 10/1000 µs

Insulation resistance at 100 VDC Capacitance at 1 MHz

Arc voltage at 1 A Glow to arc transition current Glow voltage

Weight

Operation and storage temperature
Ordering code and packing advice B88069X2890C102 = 100 pcs. in container

B88069X2890C102 A83-A600X

Cautions and warnings

Do not operate surge arresters in power supply networks, whose maximum operating voltage exceeds the minimum spark-over voltage of the surge arresters.

Surge arresters may become hot in the event of longer periods of current stress burn risk . In the event of overload the connectors may fail or the component may be destroyed.

If the contacts of the surge arresters are defective, current load can cause sparks and loud noises.

Surge arresters must be handled with care and must not be dropped. Do not continue to use damaged surge arresters.
Display of ordering codes for EPCOS products
The ordering code for one and the same EPCOS product can be represented differently in data sheets, data books, other publications, on the EPCOS website, or in order-related documents such as shipping notes, order confirmations and product labels. The varying representations of the ordering codes are due to different processes employed and do not affect the specifications of the respective products. Detailed information can be found on the Internet under

PPD AB PD / PPD AB PM

Please read Cautions and warnings and Important notes at the end of this document.
2015-04-20

Important notes

The following applies to all products named in this publication:

Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We nevertheless expressly point out that such statements cannot be regarded as binding statements about the suitability of our products for a particular customer application. As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application.

We also point out that in individual cases, a malfunction of electronic components or failure before the end of their usual service life cannot be completely ruled out in the current state of the art, even if they are operated as specified. In customer applications requiring a very high level of operational safety and especially in customer applications in which the malfunction or failure of an electronic component could endanger human life or health e.g. in accident prevention or life-saving systems , it must therefore be ensured by means of suitable design of the customer application or other action taken by the customer e.g. installation of protective circuitry or redundancy that no injury or damage is sustained by third parties in the event of malfunction or failure of an electronic component.

The warnings, cautions and product-specific notes must be observed.

In order to satisfy certain technical requirements, some of the products described in this publication may contain substances subject to restrictions in certain jurisdictions e.g. because they are classed as hazardous . Useful information on this will be found in our Material Data Sheets on the Internet Should you have any more detailed questions, please contact our sales offices.

We constantly strive to improve our products. Consequently, the products described in this publication may change from time to time. The same is true of the corresponding product specifications. Please check therefore to what extent product descriptions and specifications contained in this publication are still applicable before or when you place an order. We also reserve the right to discontinue production and delivery of products. Consequently, we cannot guarantee that all products named in this publication will always be available. The aforementioned does not apply in the case of individual agreements deviating from the foregoing for customer-specific products.

Unless otherwise agreed in individual contracts, all orders are subject to the current version of the “General Terms of Delivery for Products and Services in the Electrical Industry” published by the German Electrical and Electronics Industry Association ZVEI .

The trade names EPCOS, Alu-X, CeraDiode, CeraLink, CeraPad, CeraPlas, CSMP, CSSP, CTVS, DeltaCap, DigiSiMic, DSSP, ExoCore, FilterCap, FormFit, LeaXield, MiniBlue, MiniCell, MKD, MKK, MotorCap, PCC, PhaseCap, PhaseCube, PhaseMod, PhiCap, PQSine, SIFERRIT, SIFI, SIKOREL, SilverCap, SIMDAD, SiMic, SIMID, SineFormer, SIOV, SIP5D, SIP5K, TFAP, ThermoFuse, WindCap are trademarks registered or pending in Europe and in other countries. Further information will be found on the Internet at
More datasheets: 2450FB15K0001E | AP1515-33SL-13 | AP1515-SL-13 | 4106-002LF | 4106-002 | 3079 | ACPM-9328-BLK | ACPM-9328-TR1 | 1-NPL/603-1341 | FFPF10U30DNTU


Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived B88069X2890C102 Datasheet file may be downloaded here without warranties.

Datasheet ID: B88069X2890C102 511734