B84312C90B104

B84312C90B104 Datasheet


B84312

Part Datasheet
B84312C90B104 B84312C90B104 B84312C90B104 (pdf)
Related Parts Information
B84312C60B101 B84312C60B101 B84312C60B101
B84312C40H1 B84312C40H1 B84312C40H1
B84312F90B4 B84312F90B4 B84312F90B4
B84312C40H101 B84312C40H101 B84312C40H101
B84312C50B1 B84312C50B1 B84312C50B1
B84312C50B101 B84312C50B101 B84312C50B101
B84312C50H1 B84312C50H1 B84312C50H1
B84312C60B1 B84312C60B1 B84312C60B1
B84312C90H4 B84312C90H4 B84312C90H4
B84312C40B101 B84312C40B101 B84312C40B101
B84312F60B1 B84312F60B1 B84312F60B1
B84312C20H3 B84312C20H3 B84312C20H3
B84312F50B1 B84312F50B1 B84312F50B1
B84312F30B3 B84312F30B3 B84312F30B3
B84312F20B3 B84312F20B3 B84312F20B3
B84312F100B3 B84312F100B3 B84312F100B3
B84312C90B4 B84312C90B4 B84312C90B4
B84312C90H104 B84312C90H104 B84312C90H104
B84312C50H101 B84312C50H101 B84312C50H101
B84312C100H3 B84312C100H3 B84312C100H3
B84312C30B3 B84312C30B3 B84312C30B3
B84312C40B1 B84312C40B1 B84312C40B1
B84312C100H103 B84312C100H103 B84312C100H103
B84312C100B103 B84312C100B103 B84312C100B103
B84312C20B103 B84312C20B103 B84312C20B103
B84312C20B3 B84312C20B3 B84312C20B3
B84312C30B103 B84312C30B103 B84312C30B103
B84312C30H103 B84312C30H103 B84312C30H103
B84312C30H3 B84312C30H3 B84312C30H3
B84312C100B3 B84312C100B3 B84312C100B3
PDF Datasheet Preview
Filters for Communication Lines

Analog Systems and Control Lines

Series/Type:

B84312

Date January 2004

EPCOS AG Reproduction, publication and dissemination of this data sheet, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited. Purchase orders are subject to the General Conditions for the Supply of Products and Services of the Electrical and Electronics Industry recommended by the ZVEI German Electrical and Electronic Manufacturers' Association , unless otherwise agreed.

Filters for communication lines Analog systems and control lines

Passband up to 300 kHz Stopband attenuation up to 40 GHz

B84312

Use of coaxial feed-through capacitors on input and output Single or current-balanced chokes depending on requirement Insertion loss to CISPR 17 Also available with integrated EMP protection

Installation

Single filters are attached directly to the shielding wall. Larger numbers can be housed in filter cabinets or boxes. Various models and the matching flexible connector fittings are available.

Mechanical design

The electrical components are incorporated in an RF-tight case of tin-plated sheet steel. Filters are available for 2 or 20 lines and for upright or flat installation on shielding wall.

Model B84312C

B84312F

Installation

Upright Space-saving solution for installing a number
of different filters.

Flat

Low profile and thus advantage especially for
just one or a few filters.

Filter selection B84312C*B 2-line B84312C*H 20-line B84312F*B 2-line

Filters for communication lines Analog systems and control lines

B84312

Filter applications

The following standard filters are designed for the most common applications customized models can be produced for differing requirements.

Passband ZL IR Application

DC 600 Standard filters for telephone systems

DC 600 Telephone systems for enhanced requirements stopband attenuation of 100 dB above 10 kHz

DC 50 600 Filters for telephone systems and modem cables, conditionally for control lines with critical signal rise times

Circuit No. Series
diagram of lines B84312
2 +0020B***
20 C0020H***
2 +0090B***
20 C0090H***
2 +0040B***
20 C0040H***

DC 150 DC 300 150 DC 120 100

Data signals with balanced signal
Characteristics and ordering codes

Pass

Rmax
bandwidth

Per line

DC 600

DC 600

DC 600

DC 50 600

DC 50 600

DC 50 600

DC 120 150

DC 120 150

DC 120 150

DC 120 100

DC 120 100

DC 120 100

DC 300 150

DC 300 150

DC 600

DC 600

DC 600
* 0 = Standard filters
1 = Filters with EMP protection

Circuit diagram
Number of Ordering code lines

B84312C0020B*03

B84312F0020B*03

B84312C0020H*03

B84312C0030B*03

B84312F0030B*03

B84312C0030H*03

B84312C0040B*01

B84312F0040B*01

B84312C0040H*01

B84312C0050B*01

B84312F0050B*01

B84312C0050H*01

B84312C0050B*21

B84312F0050B*21

B84312C0050H*21

B84312C0050B*31

B84312F0050B*31

B84312C0050H*31

B84312C0060B*01

B84312F0060B*01

B84312C0090B*04

B84312F0090B*04

B84312C0090H*04

B84312C0100B*03

B84312F0100B*03

B84312C0100H*03
2 Control line filters, not matched 3 Not specified

Filters for communication lines Analog systems and control lines Insertion loss αe in passband typical

Symmetrical measurement circuit with ZL = 600

B84312

Symmetrical measurement circuit with ZL = 150

Filters for communication lines Analog systems and control lines

Unsymmetrical measurement common-mode-rejection in passband

B84312

Filter with ZL = 600 CMR >40 dB in passband

Filters for communication lines Analog systems and control lines Insertion loss αe in stopband typical

Unsymmetrical measurement circuit

B84312

Asymmetrical measurement to MIL-STD-220A

Filters for communication lines Analog systems and control lines
Adapter A bracket adapter is available for flat installation on the shielding wall. Ordering code B84298M0012C004
More datasheets: UP0.4UC-4R7-R | UP0.4UC-471-R | UP0.4UC-680-R | B84312C60B101 | B84312C40H1 | B84312F90B4 | B84312C40H101 | B84312C50B1 | B84312C50B101 | B84312C50H1


Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived B84312C90B104 Datasheet file may be downloaded here without warranties.

Datasheet ID: B84312C90B104 511709