B84299D6***A B 00* 2011--07--22 06
Part | Datasheet |
---|---|
![]() |
B84299D6300B003 (pdf) |
Related Parts | Information |
---|---|
![]() |
B84299D6050B003 |
![]() |
B84299D6300B000 |
![]() |
B84299D6101A003 |
PDF Datasheet Preview |
---|
Datasheet Power line filter for shielded rooms & secure area 250/277/480 V, 50/60 Hz, 1--100 A, 40 °C Ordering code Date Version: B84299D6***A B 00* 2011--07--22 06 EPCOS AG Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without EPCOS’ prior express consent is prohibited. Page 1 of 10 Power line filter for shielded rooms & secure area B84299D6***A B 00* Technical data and measuring conditions Rated frequency Rated temperature Overload capability thermal for 3 min per hour or for 30 s per hour Climatic category IEC 60068--1 Rated frequency B84299D60*0B003 -- Rated voltage Test voltage line to line for 2 s Test voltage line to case for 2 s B84299D6300B000 -- Rated voltage Test voltage line to line for 2 s Test voltage line to case for 2 s B84299D6*00B003 -- Rated voltage Test voltage line to line for 2 s Test voltage line to case for 2 s B84299D6101A003 -- Rated voltage Test voltage line to line for 2 s Test voltage line to case for 2 s fR TR fR Ur Utest Ur Utest Ur Utest Ur Utest 50/60 40 x IR x IR 25/85/21 50/60 250 1768 2121 250 1768 2121 480 2158 2200 277 2158 2200 Hz °C Hz V AC V DC V DC V AC V DC V DC V AC V DC V DC V AC V DC V DC Characteristics and ordering codes IR LINE LOAD Ileak 2 Rtyp terminals: threaded cabels studs #6--32 UNC 2A AWG 18 #6--32 UNC 2A AWG 18 30 M6 AWG 12 157 30 M6 AWG 10 1706 60 M8 AWG 6 1714 100 M10 AWG 2 3751 Approx. weight kg 22 Ordering code Approvals for USA, Canada UL listed cUL listed B84299D6010B003 B84299D6050B003 B84299D6300B000 B84299D6300B003 B84299D6600B003 B84299D6101A003 2 Calculation according draft proposal IEC 60939--1 Ed. 3 2008--10--29 , annex A, ”Calculation of leakage current” at 50Hz. 3 X = approval granted P = pending D = design complies with - = none Please read Cautions and warnings and Important notes at the end of this document. Page 2 of 10 B84299- D6*- A B *- 06- 7659 Power line filter for shielded rooms & secure area B84299D6***A B 00* Circuit diagram for B84299D6010B003 and B84299D6050B003 LINE LOAD L’ Circuit diagram for B84299D6300B000 LINE Circuit diagram for B84299D6300B003 LINE L1 N’ LOAD L’ N’ LOAD L1’ L2’ Please read Cautions and warnings and Important notes at the end of this document. Page 3 of 10 B84299- D6*- A B *- 06- 7659 Power line filter for shielded rooms & secure area Circuit Diagram for B84299D6600B003 LINE L1 Circuit Diagram for B84299D6101A003 LINE L B84299D6***A B 00* LOAD L1’ L2’ LOAD L’ Please read Cautions and warnings and Important notes at the end of this document. |
More datasheets: BD11007 | BD10100 | BD11012 | BD11009 | BD11005 | 10112445-020MHAHLF | 315 | 65-21/GHC-YS2U1G/2AA | FQPF5N50 | B84299D6050B003 |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived B84299D6300B003 Datasheet file may be downloaded here without warranties.