B84143-B*-R110 B84143-B*-R112
Part | Datasheet |
---|---|
![]() |
B84143B200R112 (pdf) |
Related Parts | Information |
---|---|
![]() |
B84143B120R112 |
![]() |
B84143B90R112 |
![]() |
B84143B66R112 |
![]() |
B84143B50R112 |
![]() |
B84143B36R112 |
![]() |
B84143B25R112 |
![]() |
B84143B150R112 |
PDF Datasheet Preview |
---|
3-Line Filters for Converters and Power Electronics Power line filters for three-phase systems Rated voltage 480/275 and 520/300 V~, 50/60 Hz Rated current 8 to 200 A Construction s Three-line filter s Metal case s Book size s Very high insertion loss s Low leakage current s Optimized footprint saves space s Litz wires on the load side reduce mounting time s Low weight s Degree of protection IP 201 s Design based on EN 133 200, UL 1283, CSA No.8 1986 s Optimized for long motor cables and operation under full load s UL and CSA approval pending s Frequency converters for motor drives, e.g. elevators pumps traction systems conveyor systems HVAC systems heating, ventilation and air conditioning s Wind farms s Power supplies Terminals s Line Safe-to-touch terminal blocks s Load Litz wires Marking Marking on component Manufacturer’s logo, ordering code, rated voltage, rated current, rated temperature, date code Minimum marking on packaging Manufacturer’s logo, ordering code 1 In accordance with IEC 60529:1989 EN 60529:1991 DIN VDE 0470-1 246 03/01 B84143-B*-R110 B84143-B*-R112 3-Line Filters for Converters and Power Electronics Typical circuit diagrams B84143-B8 B16-R110 LINE L1 L2 L3 B84143-B*-R110 B84143-B*-R112 LOAD L1’ L2’ L3’ B84143-B25 B200-R11* LINE L1 L2 L3 SSB1526-A LOAD L1’ L2’ L3’ SSB1527-I 247 03/01 3-Line Filters for Converters and Power Electronics B84143-B*-R110 B84143-B*-R112 Technical data Rated voltage VR Rated current I R Test voltage VP Overload capability Leakage current I leak Climatic category 480/275 V~, 50/60 Hz type -R110 520/300 V~, 50/60 Hz type -R112 Referred to 40 °C ambient temperature 1770 2 s line/line 2700 2 s lines/case 1,5 • IR for 3 min per hour or 2,5 • IR for 30 s per hour at 480 V~, 50 Hz 25/100/21 25 °C/+ 100 °C/21 days damp heat test in accordance with EN 60068-1 Characteristics and ordering codes Terminal cross section line side: load side: terminal blocks litz wires 50 16 66 25 90 25 120 50 150 50 200 95 I leak typ1 mA < 14 < 14 < 14 < 14 < 14 < 14 < 14 < 14 < 14 < 14 Rtyp 26 13 10 6,5 4,3 2,7 2,0 1,4 0,9 0,5 Approx. Ordering code weight B84143-B8-R110 B84143-B16-R110 B84143-B25-R11* B84143-B36-R11* B84143-B50-R11* B84143-B66-R11* B84143-B90-R11* B84143-B120-R11* B84143-B150-R11* 13,5 B84143-B200-R11* Compilation of ordering code Replace the asterisk * by the code number for the required version 0 = 480 / 275 V 2 = 520 / 300 V 1 At rated operation 248 03/01 3-Line Filters for Converters and Power Electronics Dimensional drawings B84143-B8-R110, B84143-B16-R110 ATnesrcmhluinsas-l kblelomcmkesn44mmm2 80 40 31 15 PE M6 x 25 L1 L2 230 215±0,5 Marking LINE LOAD 0,5 1 6,5 25±0,3 46 B84143-B*-R110 B84143-B*-R112 300±10 LiLtzitzweire L3’ L2’ L1’ PE AWdeirenednhüdlsfeerrule LLitiztzenwbeirzeeimchanrukning gs SSB1291-1 B84143-B25-R11*, B84143-B36-R11* TAensrmchilnuassl bkleomckmsen6 6mmmm22 150 75 60 30 PE M6 x 25 L1 L2 280 265±0,5 Marking LINE LOAD 35±0,3 400±10 LiLtzitzwe ire L3’ L2’ L1’ AWdeirrenednhdülsfe rrule LLitiztzenwbeirzeeimchanrukninggs SSB1292-9 249 03/01 150 75 52 30 3-Line Filters for Converters and Power Electronics B84143-B50-R11* ATnesrcmhliunsaslkblelomcmksen1166mmmm22 PE M6 x 25 L1 L2 L3 B84143-B66-R11* 80 TAensrmchilnuassl bkleomckmsen2525mmmm22 330 315±0,5 Marking LINE LOAD 150 75 52 35 PE M10 x 35 L1 L2 L3 |
More datasheets: X2-SE1-EC-A-25 | ERT-X2-SE1-BD1 | X2-SE4-EC-A | B84143B120R112 | B84143B90R112 | B84143B66R112 | B84143B50R112 | B84143B36R112 | B84143B25R112 | B84143B150R112 |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived B84143B200R112 Datasheet file may be downloaded here without warranties.