B84112B
Part | Datasheet |
---|---|
![]() |
B84112BL110 (pdf) |
Related Parts | Information |
---|---|
![]() |
B84112B0000K030 |
PDF Datasheet Preview |
---|
EMC Filters Series/Type: B84112B The following products presented in this data sheet are being withdrawn. Ordering Code Substitute Product B84112B0000P030 B84112B0000L110 B84112B0000L060 Date of Withdrawal 2013-04-12 2013-04-12 2013-04-12 Deadline Last Orders 2013-07-31 2013-07-31 2013-07-31 Last Shipments 2013-10-31 2013-10-31 2013-10-31 EPCOS AG Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited. EPCOS AG is a TDK Group Company. Ordering Code Substitute Product B84112B0000L030 B84112B0000L020 B84112B0000L010 B84112B0000K060 B84112B0000K030 B84112B0000K010 Date of Withdrawal 2013-04-12 2013-04-12 2013-04-12 2013-04-12 2013-04-12 2013-04-12 Deadline Last Orders 2013-07-31 2013-07-31 2013-07-31 2013-07-31 2013-07-31 2013-07-31 Last Shipments 2013-10-31 2013-10-31 2013-10-31 2013-10-31 2013-10-31 2013-10-31 For further information please contact your nearest EPCOS sales office, which will also support you in selecting a suitable substitute. The addresses of our worldwide sales network are presented at 2-line filters SIFI-B for enhanced insertion loss B84112B Power line filters for 1-phase systems Rated voltage 250 V DC/AC, 50/60 Hz Rated current 1 to 20 A Alternative version • Series B84112G SIFI-G offers a low-cost solution Construction • 2-line filters • Metal case • Polyurethane potting UL 94 V-0 • Compact design • Optimized leakage current • Cost-optimized construction • Also for assembly on top-hat rails • ENEC10, UL and CSA approval • Switch-mode power supplies in industrial electronics telecommunications data systems medical equipment • DC applications Case styles and terminal styles Case style A Tab connectors on face ends, lateral fixing lugs. Particularly suitable for mounting on a shielding wall. Case style B Tab connectors on face ends, fixing lugs on face ends. Case style K IEC connector as per IEC 60320 C 14 on line side, tab connectors on load side, mounting holes with metric thread. Case style L Litz wires on face ends, fixing lugs on face ends Case style P Pins fitting PCB standard grid Marking Marking on component Manufacturer’s logo, ordering code, rated voltage, rated current, rated temperature, climatic category, date code Minimum marking on packaging Manufacturer’s logo, ordering code Please read Cautions and warnings and Important notes at the end of this document. 2 01/06 2-line filters SIFI-B for enhanced insertion loss Circuit diagram LINE L LOAD L’ B84112B N’ SSB0525-W Technical data and measuring conditions Rated voltage VR Rated current IR Test voltage Vtest Leakage current lleak Climatic category IEC 60068-1 Approvals 250 V DC/AC, 50/60 Hz Referred to 40 °C ambient temperature 1414 V DC, 2 s line/line 2700 V DC, 2 s lines/case At 230 V AC, 50 Hz 25/085/21 °C/+85 °C/21 days damp heat test EN 133200, UL 1283, CSA C22.2 No.8 Please read Cautions and warnings and Important notes at the end of this document. 3 01/06 2-line filters SIFI-B for enhanced insertion loss B84112B Characteristics and ordering codes IR CR VR = 250 V DC/AC, 50/60 Hz 1 2 x µF X2 2 x 2 x 4700 pF Y2 2 x µF X2 2 x 2 x 4700 pF Y2 3 2 x µF X2 2 x 2 x 4700 pF Y2 6 2 x µF X2 2 x 2 x 4700 pF Y2 10 2 x µF X2 2 x 2 x 4700 pF Y2 20 2 x µF X2 2 x 2 x 4700 pF Y2 Ileak Case Approx. Ordering code style weight Mounting plate for top-hat rail ordering code < A 110 B 110 K 140 L 110 < A 110 B 110 L 110 < A 140 B 140 K 210 L 140 P 140 < A 150 B 150 K 210 L 150 < A 200 B 200 L 200 < A 700 B 700 B84112B0000A010 B84112B0000B010 B84112B0000K010 B84112B0000L010 C62122A0132B091 B84112B0000A020 B84112B0000B020 C62122A0132B091 B84112B0000L020 B84112B0000A030 B84112B0000B030 B84112B0000K030 B84112B0000L030 B84112B0000P030 C62122A0132B092 B84112B0000A060 B84112B0000B060 B84112B0000K060 B84112B0000L060 C62122A0132B092 B84112B0000A110 B84112B0000B110 C62122A0132B092 B84112B0000L110 B84112B0000A120 B84112B0000B120 C62122A0132B092 Please read Cautions and warnings and Important notes at the end of this document. 4 01/06 2-line filters SIFI-B for enhanced insertion loss B84112B Case styles and dimensions Case IR style Dimensions mm b1 b2 b3 b4 45 70 45 51 45 45 70 45 h1 h2 50 70 50 70 20 32 50 20 50 70 20 50 70 20 32 See dimensional drawing 20 32 Litz Style mm2 1015 AWG18 AWG18 AWG18 AWG18 AWG16 See dimensional drawing Please read Cautions and warnings and Important notes at the end of this document. |
More datasheets: AM80A-048L-012F60 | AM80A-048L-050F40 | AM80A-048L-033F50 | AM80A-048L-120F18 | AM80A-048L-150F16 | AM80A-048L-240F10 | AM80A-300L-150F16 | AM80A-300L-065F33 | AM80A-048L-022F60 | B84112B0000K030 |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived B84112BL110 Datasheet file may be downloaded here without warranties.