NTC thermistors for temperature measurement

Probe assemblies

Series/Type Date:

B57504 March 2006

EPCOS AG Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited.

Temperature measurement Probe assemblies

B57504 K504

Applications Temperature measurement in water boilers e.g. coffee machines other home appliances

Features Short response time Medium-resistant stainless steel tube Thermistor with epoxy resin encapsulation PTFE-insulated leads of silver-plated copper wires, AWG 28 JST XHP-2 connector Plastic ring for easy mounting

Options Alternative resistance ratings, rated temperatures, resistance tolerances, lead lengths and connectors available on request.

Dimensional drawing

Delivery mode Bulk

General technical data

Dimensions in mm Approx. weight 3 g

Climatic category Maximum operating temperature Max. power Resistance tolerance Rated temperature Dissipation factor Thermal time constant Thermal cooling time constant Heat capacity Insulation resistance Test voltage

IEC 60068-1
at 25 °C
in air in water in air

V = 500 VDC t = 1 s

Top,max P25 TR Cth Rins Vtest
30/100/56 120 60 ±2 50 approx. 5 approx. 75 approx. 375 >100 1250
°C mW % °C mW/K s mJ/K VAC
Electrical specification and ordering codes
3485

No. of R/T characteristic 8407

B0/100 K 3450 ±1%
Ordering code B57504K0852A001

Please read Important notes and Cautions and warnings at the end of this document.

Page 2 of 7

Temperature measurement Probe assemblies

B57504 K504

Note The plug housing is specified for a temperature range from °C +85 °C.

Reliability data

Test

Storage in dry heat

Standard

IEC 60068-2-2

Storage in damp heat, steady state

Storage in coldness

Rapid temperature cycling in water

Vibration resistance

IEC 60068-2-6

Voltage proof test

Insulation test

Test conditions
typical

Storage at maximum operating < 2%
temperature T 120 °C t 1000 h

Temperature of air 60 °C Relative humidity of air 93%

Duration 1000 h

Storage at lower
category temperature in air

T °C t 1000 h

Lower test temperature 15 °C Upper test temperature 96 °C Dwell time 20 s

Time to change from lower to
upper temperature <10 s

Number of cycles 1000

Medium water

Frequency range 10 to 500 Hz < 2%

Amplitude mm/ 10 g

Duration 3 x 2 h
1250 VAC,

The sensors are placed in a
vessel containing metallic balls of
1 mm diameter with total
immersed head . The applied
voltage is 500 VDC.