W4E250-CH02-70

W4E250-CH02-70 Datasheet


W4E250-CH02-70

Part Datasheet
W4E250-CH02-70 W4E250-CH02-70 W4E250-CH02-70 (pdf)
PDF Datasheet Preview
W4E250-CH02-70

AC axial fan
sickled blades S series with full round nozzle
ebm-papst Mulfingen GmbH & Co. KG Bachmühle 2
• D-74673 Mulfingen Phone +49 7938 81-0 Fax +49 7938 81-110

Limited partnership
• Headquarters Mulfingen County court Stuttgart
• HRA 590344

General partner Elektrobau Mulfingen GmbH
• Headquarters Mulfingen County court Stuttgart
• HRB 590142

Nominal data

Type Motor

W4E250-CH02-70 M4E068-BF

Phase Nominal voltage Frequency

VAC 230

Hz 50

Type of data definition

Valid for approval / standard

UL 2111

Speed
min-1 1400
1350
1640

Power input

Current draw

Motor capacitor

Capacitor voltage

VDB 400

Max. back pressure

Pa 20

Max. ambient temperature °C 40

Starting current
ml = max. load
• me = max. efficiency
• fa = running at free air
• cs = customer specs
• cu = customer unit Subject to alterations
fa CE 1640 44 400 27 60
fa CE 1570 50 400 50 60

W4E250-CH02-70

AC axial fan
sickled blades S series with full round nozzle

Technical features

Mass Size Surface of rotor Material of blades Material of wall ring Material of guard grille Number of blades Direction of air flow Direction of rotation Type of protection Insulation class Humidity class Max. permissible ambient motor temp. transp./ storage Min. permissible ambient motor temp. transp./storage Mounting position Condensate discharge holes Operation mode Motor bearing Touch current acc. IEC 60990 measuring network Fig. 4, TN system Motor protection Cable exit Protection class Product conforming to standard Approval
kg 250 mm Coated in black Sheet steel, coated in black Sheet steel, pre-galvanised and coated in black plastic Steel, phosphated and coated in black plastic 7 "V" Counter-clockwise, seen on rotor IP 44 Depending on installation and position as per EN 60034-5 "B" F5 + 80 °C
- 40 °C

Shaft horizontal or rotor on bottom rotor on top on request Rotor-side S1 Ball bearing < mA

Thermal overload protector TOP wired internally Variable I if protective earth is connected by customer EN 60335-1 UL 2111 CSA C22.2 Nr.77

W4E250-CH02-70 Product drawing
More datasheets: CY7C1069AV33-12ZXCT | MGA-86576-STRG | MGA-86576-TR1G | 26800B-443 | DKSB1003A | M39154 SL001 | M39154 SL005 | M39154 SL002 | 76000900 | HTW-00-BLUE


Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived W4E250-CH02-70 Datasheet file may be downloaded here without warranties.

Datasheet ID: W4E250-CH02-70 510870