Part | Datasheet |
---|---|
![]() |
BK/C519-250MA (pdf) |
Related Parts | Information |
---|---|
![]() |
BK/C519-750MA |
![]() |
BK/C519-4A |
![]() |
BK/C519-3.5A |
![]() |
BK/C519-375MA |
![]() |
BK/C519-7A |
![]() |
BK/C519-1.25A |
![]() |
BK/C519-125MA |
![]() |
BK/C519-600MA |
![]() |
BK/C519-350MA |
![]() |
BK/C519-1.6A |
![]() |
BK/C519-2.25A |
![]() |
BK/C519-500MA |
![]() |
BK/C519-3A |
![]() |
BK/C519-1A |
![]() |
BK/C519-1.5A |
![]() |
BK/C519-5A |
![]() |
BK/C519-2.5A |
![]() |
BK/C519-2A |
PDF Datasheet Preview |
---|
5mm x 15mm Fuses C519 Series, Time Delay, Glass Tube • Time delay • 5mm x 15mm physical size • Glass tube, nickel-plated brass endcap construction • Optional sleeve is flexible flouropolymer U.L. flammability rating VW-1 . • UL Listed product meets standard UL 248-14 ELECTRICAL CHARACTERISTICS Rated Current Amp Rating Opening Time 125mA - 250mA 135% 200% 60 minutes max. 3 seconds min. 120 seconds max. 100% 4 hours min. 470mA 30 minutes max. 350mA 600mA 90 seconds max. 2 seconds max. 500 milliseconds max. 135% 60 minutes max. 375mA - 5A 200% 3 seconds min. 120 seconds max. Agency Information • UL Listed Card C519 125mA-250mA and 375mA-3A Guide JDYX, File E19180 • UL Recognized Card C519 350mA, and 3.5A-7A Guide JDYX2, File E19180 • CSA Certification Card C519 125mA-250mA and 375mA-3A Class 1422-01, LR65063 RoHS 2002/95/EC Dimensions Drawing Not to Scale Ordering • Specify packaging, product, and option code • For -R option, drop mA or A from product code i.e. C519-3-R Product Code C519-125mA C519-250mA C519-350mA C519-375mA C519-500mA C519-600mA C519-750mA C519-1A C519-1.25A C519-1.5A C519-1.6A C519-2A C519-2.25A C519-2.5A C519-3A C519-3.5A C519-4A C519-5A Voltage Rating AC 250V 125V SPECIFICATIONS Interrupting Rating Typical DC Cold at Rated Voltage Resistance* 600V 250V 125V ohms 10,000A 10,000A 10,000A 10,000A 10,000A 10,000A 10,000A 10,000A 100A 10,000A 100A 10,000A 100A 10,000A 100A 10,000A 100A 10,000A 100A 10,000A 100A 10,000A 400A 400A 400A * DC Cold Resistance Measured at <10% of rated current † Typical Melting I2t A2Sec Typical I2t at 10 times rated current Typical Voltage Drop Voltage drop was measured at 25°C±3°C ambient temperature at rated current Typical Melting I2t† Typical Voltage Drop 770 430 530 470 440 350 310 230 220 240 200 170 180 190 150 130 150 5mm x 15mm Fuses C519 Series, Time Delay, Glass Tube TIME CURRENT CURVE Packaging Code BK BK1 |
More datasheets: BK/C519-1.25A | BK/C519-125MA | BK/C519-600MA | BK/C519-350MA | BK/C519-1.6A | BK/C519-2.25A | BK/C519-500MA | BK/C519-3A | BK/C519-1A | BK/C519-1.5A |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived BK/C519-250MA Datasheet file may be downloaded here without warranties.