Packaging Code SP2 TR1
Part | Datasheet |
---|---|
![]() |
TR1/6125TD750MA (pdf) |
Related Parts | Information |
---|---|
![]() |
TR1/6125TD7A |
PDF Datasheet Preview |
---|
Brick Fuses 6125TD Series, Time Delay • Time Delay surface mount fuse capable of replacing glass tube fuses in certain applications • Environmentally rugged, complies with EIA-IS-722 Standard • Solder Immersion Compatible • Targeted for Consumer Electronics ELECTRICAL CHARACTERISTICS % of Amp Rating Opening Time 100% 4 Hours Minimum 200% 1 Second Minimum 200% 2-4 Seconds Typical 200% 60 Seconds Maximum Agency Information • UL Recognition Guide & File numbers JDYX2 & E19180. • CSA Component Acceptance 053787 C 000 & Class No 1422 Environmental Data • Life Test MIL-STD-202, Method 108A, Test Condition D • Load Humidity MIL-STD-202, Method 103B • Moisture Resistance MIL-STD-202, Method 106E • Thermal Shock MIL-STD-202, Method 107D, air-to-air • Case Resistance EIA/IS-722 • Resistance to Dissolution of Metallization: ANSI J-STD-002, Test D • Mechanical Shock MIL-STD-202, Method 213B, Test Condition A • High Frequency Vibration MIL-STD-202, Method 204D, Test Condition D • Resistance to Solvents MIL-STD-202, Method 215A Ordering • Specify product code and packaging code Dimensions inches Land Pattern Soldering Method • Wave Immersion 260°C, 3 sec max. • Infrared 260°C, 30 sec max. Product Code 6125TD500mA 6125TD750mA 6125TD1A 6125TD1.5A 6125TD2A 6125TD2.5A 6125TD3A 6125TD3.5A 6125TD4A 6125TD5A 6125TD7A Voltage Rating 125V 125V 125V 125V 125V 125V 125V 125V 125V 125V 125V SPECIFICATIONS Interrupting DC Cold Rating* Resistance** ohms 125VAC 60VDC min. typ. max. Typical Melting I2t† Typical Voltage 245 mV 250 mV 256 mV 125 mV 133 mV 130 mV 97 mV 95 mV 106 mV 100 mV 99 mV * AC Interrupting Rating Measured at designated voltage, 100% power factor DC Interrupting Rating Measured at designated voltage, time constant of less than 50 microseconds, battery source ** DC Cold Resistance Measured at 10% of rated current † Typical Melting I2t Measured with a battery bank at rated DC voltage, 10x-rated current not to exceed IR , time constant of calibrated circuit less than 50 microseconds Typical Voltage Drop Measured at rated current after temperature stabilizes Device designed to carry rated current for four hours minimum. An operating current of 80% or less of rated current is recommended, with further derating required at elevated ambient temperatures. Brick Fuses 6125TD Series, Time Delay TIME CURRENT CURVE 250mA and 375mA to be determined Packaging Code SP2 TR1 PACKAGING CODE Description 50 piece sample Standard Package This is an insert 1000 pieces of fuses on 12mm tape-and-reel on a 7 inch 177mm reel per EIA Standard 481 Cooper Electronic Technologies 2003 Visit us on the Web at |
More datasheets: 1N5405 | DWRS380A | LWRS380A | LWRS440A | LWRS220A | DWRS440A | DWRS220A | PWRS440A | PWRS220A | 2676 |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived TR1/6125TD750MA Datasheet file may be downloaded here without warranties.