Brick Fuses
6125TD Series, Time Delay
• Time Delay surface mount fuse capable of replacing glass tube fuses in certain applications
• Environmentally rugged, complies with EIA-IS-722 Standard
• Solder Immersion Compatible
• Targeted for Consumer Electronics

ELECTRICAL CHARACTERISTICS
% of Amp Rating

Opening Time
100%
4 Hours Minimum
200%
1 Second Minimum
200%
2-4 Seconds Typical
200%
60 Seconds Maximum

Agency Information
• UL Recognition Guide & File numbers JDYX2 & E19180.
• CSA Component Acceptance 053787 C 000 & Class No 1422

Environmental Data
• Life Test MIL-STD-202, Method 108A, Test Condition D
• Load Humidity MIL-STD-202, Method 103B
• Moisture Resistance MIL-STD-202, Method 106E
• Thermal Shock MIL-STD-202, Method 107D, air-to-air
• Case Resistance EIA/IS-722
• Resistance to Dissolution of Metallization:

ANSI J-STD-002, Test D
• Mechanical Shock MIL-STD-202, Method 213B, Test

Condition A
• High Frequency Vibration MIL-STD-202, Method 204D,

Test Condition D
• Resistance to Solvents MIL-STD-202, Method 215A
Ordering
• Specify product code and packaging code

Dimensions
inches

Land Pattern

Soldering Method
• Wave Immersion 260°C, 3 sec max.
• Infrared 260°C, 30 sec max.

Product Code
6125TD500mA 6125TD750mA 6125TD1A 6125TD1.5A 6125TD2A 6125TD2.5A 6125TD3A 6125TD3.5A 6125TD4A 6125TD5A 6125TD7A

Voltage

Rating
125V
125V
125V
125V
125V
125V
125V
125V
125V
125V
125V

SPECIFICATIONS

Interrupting

DC Cold

Rating*

Resistance** ohms
125VAC 60VDC min. typ. max.

Typical Melting

I2t†

Typical Voltage 245 mV 250 mV 256 mV 125 mV 133 mV 130 mV 97 mV 95 mV 106 mV 100 mV 99 mV
* AC Interrupting Rating Measured at designated voltage, 100% power factor DC Interrupting Rating Measured at designated voltage, time constant of less than 50 microseconds, battery source
** DC Cold Resistance Measured at 10% of rated current † Typical Melting I2t Measured with a battery bank at rated DC voltage, 10x-rated current not to exceed IR , time constant of calibrated circuit less than 50 microseconds Typical Voltage Drop Measured at rated current after temperature stabilizes Device designed to carry rated current for four hours minimum. An operating current of 80% or less of rated current is recommended, with further derating required at elevated ambient temperatures.

Brick Fuses
6125TD Series, Time Delay

TIME CURRENT CURVE
250mA and 375mA to be determined

Packaging Code SP2 TR1

PACKAGING CODE

Description 50 piece sample Standard Package This is an insert 1000 pieces of fuses on 12mm tape-and-reel on a 7 inch 177mm reel per EIA Standard 481

Cooper Electronic Technologies 2003

Visit us on the Web at
More datasheets: 1N5405 | DWRS380A | LWRS380A | LWRS440A | LWRS220A | DWRS440A | DWRS220A | PWRS440A | PWRS220A | 2676


Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived TR1/6125TD750MA Datasheet file may be downloaded here without warranties.

Datasheet ID: TR1/6125TD750MA 506747