MPA7030-1R5-R

MPA7030-1R5-R Datasheet


MPA7030 Series

Part Datasheet
MPA7030-1R5-R MPA7030-1R5-R MPA7030-1R5-R (pdf)
PDF Datasheet Preview
High Frequency, High Current Power Inductors

MPA7030 Series

HALOGEN

HF Pb

FREE

SMD Device
• Halogen free
• 165°C maximum total temperature operation
• 7.6x7.0x3.0mm maximum surface mount package
• Magnetically shielded
• Rugged construction
• Handles high transient inrush current spikes
• Inductance Range from 1.5µH to 8.2µH
• Current range from to Amps
• RoHS compliant
• Automotive electronics under the hood, interior/exterior
• Voltage Regulator Module VRM
• Multi-phase regulators
• Point-of-load modules
• Desktop and server VRMs and EVRDs
• Base station equipment
• Notebook regulators
• POL Converters
• Battery power systems
• Data networking and storage
• Graphics cards
• LCD Displays, LED drivers

Environmental Data
• Storage temperature range -55°C to +165°C
• Operating temperature range -55°C to +165°C
ambient + self-temperature rise
• Solder reflow temperature J-STD-020D compliant
• Complies with AEC-Q200 standard

Packaging
• Supplied in tape and reel packaging, 1500 parts per 13” reel

Part

Number6 MPA7030-1R5-R MPA7030-2R2-R MPA7030-3R3-R MPA7030-4R7-R MPA7030-6R8-R MPA7030-8R2-R

OCL1
± 20% uH

Irms12 Amps

Product Specifications

Irms23

Isat4

SRF MHz

Amps

Amps

Minimum

DCR mΩ

DCR mΩ

Typical Maximum

K-Factor5

Open Circuit Inductance OCL Test Parameters 100kHz, 0.25Vrms, 0.0Adc Irms1 DC current for an approximate temperature rise of 40°C without core loss at 85°C
ambient temperature. Derating is necessary for AC currents. PCB layout, trace thickness and width, air-flow, and proximity of other heat generating components will affect the temperature rise. It is recommended that the temperature of the part not exceed 165°C under worst case operating conditions verified in the end application. Irms2 DC current rating for 125°C ambient temperature operation. Derating is necessary for AC currents. PCB layout, trace thickness and width, air-flow, and proximity of other heat generating components will affect the temperature rise. It is recommended that the temperature of the part not exceed 165°C under worst case operating conditions verified in the end application.

Isat Peak current for approximately 20% rolloff at +25°C 8R2 = K-Factor Used to determine Bp-p for core loss see graph . Bp-p = K * L * Bp-p Gauss ,

K-Factor from table , L Inductance in uH , Peak-to-peak ripple current in amps . Part Number Definition MPA7030-xxx-R
- MPA7030 = Product code and size - xxx= Inductance value in uH, R = decimal point. If no “R” is present, then third digit equals the number of zeros.
- “-R” suffix = RoHS compliant
0611 BU-SB11644

Page 1 of 5

Data Sheet 4421

Dimensions - mm

Packaging Information - mm

Supplied in tape and reel packaging, 1500 parts per 13” diameter reel.
More datasheets: HQCCWM101GAH6A | HQCCWM150GAH6A | HQCCWM271GAH6A | HQCCWM560GAH6A | HQCCAM681GAH6A | HQCCWM180GAH6A | HQCCWM240GAH6A | 36-1/B4C-AKNB | DA-70226 | PI7C7300ANAE


Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived MPA7030-1R5-R Datasheet file may be downloaded here without warranties.

Datasheet ID: MPA7030-1R5-R 506351