ESS20-003-DC24V-2A

ESS20-003-DC24V-2A Datasheet


Electronic Circuit Breaker ESS20

Part Datasheet
ESS20-003-DC24V-2A ESS20-003-DC24V-2A ESS20-003-DC24V-2A (pdf)
Related Parts Information
ESS20-003-DC24V-0.5A ESS20-003-DC24V-0.5A ESS20-003-DC24V-0.5A
ESS20-003-DC24V-10A ESS20-003-DC24V-10A ESS20-003-DC24V-10A
ESS20-003-DC24V-1A/2A ESS20-003-DC24V-1A/2A ESS20-003-DC24V-1A/2A
ESS20-003-DC24V-4A ESS20-003-DC24V-4A ESS20-003-DC24V-4A
ESS20-003-DC24V-1A ESS20-003-DC24V-1A ESS20-003-DC24V-1A
ESS20-003-DC24V-6A ESS20-003-DC24V-6A ESS20-003-DC24V-6A
ESS20-003-DC24V-8A ESS20-003-DC24V-8A ESS20-003-DC24V-8A
ESS20-003-DC24V-3A/6A ESS20-003-DC24V-3A/6A ESS20-003-DC24V-3A/6A
PDF Datasheet Preview
Electronic Circuit Breaker ESS20

Electronic circuit breaker type ESS20 is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 24 V switch-mode power supply.

DC 24 V power supplies, which are widely used in industry today, will shut down the output in the event of an overload with the result that one faulty load in the system can lead to complete disconnection of all loads. As well as an unidentified failure this also means stoppage of the whole system.

Through selective disconnection the ESS20 responds much faster to overload or short circuit conditions than the switch-mode power supply. This is achieved by a combination of active current limitation and well-proven circuit breaker technology including physical isolation. The ESS20 limits the highest possible current to times the set rated current of the circuit breaker. Thus it is possible to switch on even capacitive loads or lamp loads, but they are disconnected only in the event of an overload or short circuit.

ESS20 Technical data Tambient = 25°C, operating voltage UB = DC 24 V

For optimal adjustment to the application conditions the current rating of the ESS20 can be selected by a switch 3 A or 6 A . Failure and status indication are provided by a bicolour LED and an integral signal contact.

Operating data

Operating voltage UB Current rating IN Power consumption

DC 24 V 18 32 V 3 A or 6 A selected by means of a switch typically 13 mA

The ESS20 features a width of only mm and can be plugged into the E-T-A power distribution socket Module 17plus, ensuring ease of installation and saving space in control cabinets.

Trip current bimetal

Status indication by means of
typ. 1A
only in the event of a failure, before physical isolation
bicolour LED GREEN unit is ON, power-MOSFET is switched on ORANGE in the event of overload or short circuit until physical isolation LED not lighted push button in OFF position potential-free signal contact changeover contact OFF-position of push button
q Selective load protection with physical isolation in the event of a fault q All types of loads can be connected DC motors etc. on request q Active current limitation times rated current for safe

Load circuit
internal bimetal fail-safe element trips, push button moves into OFF position
connection of capacitive loads and on overload/short circuit q Electronic trip characteristic

Load output

Power-MOSFET switching output high side switch
q One unit for two current ratings 3 A and 6 A selectable

Max. data of load

DC 24 V / 6 A resistive, inductive,
q Manual ON/OFF button push-push actuation q Clear status and failure indication q Width per unit only mm
capacitive, lamp load
with side-by-side mounting 6A at Tamb = +40°C and 100% ON duty 5A at Tamb = +50°C and 100% ON duty
q Plug-in mounting utilising power distribution system Module 17plus

Voltage drop at IN
typically. 130 mV / 3 A typically 260 mV / 6 A

Approvals

VDE, UL approval pending

Overload disconnection
typically x IN x IN

Short-circuit current IK
typically x IN max. 2 x IN / active current limitation

Trip time
see time/current characteristics
for physical isolation
typ. 5 sec at Iload > x IN
for electronic disconnection typ. 5 sec 100 ms at Iload > x IN
Ordering information

Fault indication, signal output

Fault indications
potential-free auxiliary contact change-over SC-SO / SC-SI simultaneously with physical isolation max. DC 30 V / A, min. 10 V / 10 mA

Signal output
blue push button in ON position signal contact SC-SO is closed SC-SI is open blue push button in OFF position signal contact SC-SO is open SC-SI is closed

Visual indication

LED lighted after typ. 50 ms in ORANGE until physical isolation

Type No. ESS20 Electronic Circuit Breaker for DC 24 V applications

Version 00 standard

Control input 0 without signal contact 3 with signal contact changeover contact

Input voltage DC 24 V rated voltage DC 24 V

Current rating 3 A/6 A selectable switch
ESS20 - 00 3 - DC 24 V - 3 A/6 A ordering example recommended type

General data

Ambient temperature
°C without condensation, see EN 60204-1

Storage temperature

Backup fuse for ESS20
not required because of the integral redundant fail-safe element thermal circuit breaker in Vorb.

Basic circuit diagram

Blade terminals
mm to DIN 46244-A6, 3-0,8

Housing material
plastics material

Mounting of housing
plug-in mounting utilising power distribution system Module 17plus
control

Vibration Degree of protection
3 g, test to IEC 68-2-6 test Fc

Housing IP 20 DIN 40050, Terminals IP 00 DIN 40050

LINE + DC 24 V

Emission EN 50081-1

EMC directive, CE logo Susceptibility EN 61000-6-2
current short circuit / measurement overload

Insulation co-ordination kV/2

ON / OFF

IEC 60934
re-inforced insulation in operating area

Dielectric strength operating area
see dimensions test voltage AC 1000 V
status indication green / orange
installation area
test voltage AC 500 V
load circuit-signal contact test voltage AC 500 V
3A 6A
rated current IN

Rsense

Insulation resistance
>100 DC 500 V

OFF condition
[LINE + LOAD + ]

Dimensions W x H x D x 105 x 60 mm

Mass
Ordering information

Voltage rating without ESS20 :

AC 433 V DC 65 V

Current rating
without ESS20

LINE feed 1

LOAD output 2

Reference potential GND 11 10 A

Individual signal 12
1 A with ESS20 0,5 A

Group signal / 13-14
1 A with ESS20 0,5 A
17PLUS-Q02-00

Module 17plus, middle part, two-way
17PLUS-Q00-LR-EES one each left- and right-side terminal block
for ESS20
17PLUS-QA0-LR-EES one each left- and right-side terminal block
with screw terminal for busbar for ESS20

Internal resistance values without ESS20

LINE-LOAD 1-2 Group signal 13-14 per module
5 8 per pole +5 for each additional module

Busbar for power distribution
insulated busbar
blue or red :

Imax 32 A
non-insulated busbar:

Imax 50 A

The non-insulated busbar, too, meets brush contact safety
standards when fitted.

Dielectric strength of Module 17plus without ESS20
between main circuits without busbar 1,500 V
main circuit to auxiliary circuit:
1,500 V
between auxiliary circuits:
1,500 V

Mass Module 17plus middle part terminal blocks pair
approx. 85 g approx. 30 g
¤ Germany 0 91 87 10-0 - USA 847 827-7600 - UK 01296 420336 -

Issue E

ESS20 - Accessories Module 17plus

Dimensions
More datasheets: AD9841AJSTZ | 43-01036 | 43-01032 | 43-01033 | 43-01034 | ESS20-003-DC24V-0.5A | ESS20-003-DC24V-10A | ESS20-003-DC24V-1A/2A | ESS20-003-DC24V-4A | ESS20-003-DC24V-1A


Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived ESS20-003-DC24V-2A Datasheet file may be downloaded here without warranties.

Datasheet ID: ESS20-003-DC24V-2A 510425